• 제목/요약/키워드: 방전시간

Search Result 541, Processing Time 0.034 seconds

Measurement of Fluorescence Signal Strength of NO Particle Using ICCD (ICCD를 이용한 NO입자의 형광신호강도 측정)

  • 전용우;박원주;이광식;이홍식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.23-30
    • /
    • 2001
  • In this paper, the discharge image of NO particles wire-cylinder type electrode in the discharge reactor where AC dielectric barrier type corona discharge occurred and horizontal and vertical signal intensity at each flourescence emission during discharge and the horizontal and vertical signal strength of NO particles at flourescence emission wavelength band[236[nm], 247[nm]], were measured were measured by ICCD Camera. In addition discharge images and signal intensities in accordance with discharge time were measured to figure out the discharge mechanism. It was found that the strongest horizontal and vertical signal intensity of NO particles were observed at 247[nm] band, but no big difference in the horizontal and vertical signal intensity in accordance with discharge time was seen. In particular, the phenomenon image occuring inside the discharge reactor and wavelength ware able to be carried based on the measured data.

  • PDF

The Surface flashover properties of Molded Transformer in Underground Premises (지하구내에 설치된 변압기의 연면방전 특성)

  • Kim, N.S.;Song, W.C.;Lee, K.H.;Lee, M.W.;Bang, Y.K.;Jung, J.S.;Park, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2129-2131
    • /
    • 2005
  • 최근 건축물의 대형화로 인해 대용량의 전기설비가 건물의 지하에 설치되고 있지만 전기설비에 대한 특별한 안전 대책 마련이 미비한 실정이다. 본 논문은 지하 구내에 설치된 몰드 변압기가 침수되었을 경우 발생될 수 있는 1차 재해와 2차 재해에 대한 피해를 최소화하기 위한 연구의 기초 단계로 실제 지하구내에 설치된 몰드 변압기를 실험 시편으로 선택하여 거리에 따른 연면 파괴 전압과 전류파형 등을 분석하였다. 분석결과 전극간 간격이 커질수록 연면방전전압이 증가하는 것으로 나타났으며, 방전전류의 피크치도 높아짐을 알 수 있다. 또한, 전극간의 간격이 커질수록 방전시간이 증가하였으며 방전시간의 증가로 인해 절연물의 손상도 증대되었을 것으로 생각된다.

  • PDF

Development of a DC Pulse Atmospheric Micro Plasma using a Voltage Doubled Capacitive Ballast

  • Ha, Chang-Seung;Cha, Ju-Hong;Kim, Dong-Hyeon;Lee, Hae-Jun;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.157.1-157.1
    • /
    • 2013
  • 외부 Ballast Capacitor를 이용한 Voltage Doubler 전원장치를 이용하여 Micro size의 대기압 플라즈마를 발생장치를 개발하였다. 2개의 외부 Capacitor를 병렬로 연결하여 충전한 다음 외부 Capacitor를 직렬로 연결하여 전압을 2배압 시킨 상태에서 방전이 일어나도록 하였다. Capacitor의 충 방전 제어는 Switch Device인 Insulated Gate Bipolar Transistor (IGBT)를 사용하였다. 개발된 대기압 플라즈마는 외부 Capacitor와 인가전압을 독립적으로 변화시킬 수 있기 때문에 방전 시 전류 전압을 독립적으로 제어할 수 있으며 용도에 따라 Glow 방전에서 Arc 방전까지 제어가 가능하다. 본 연구에서는 900 V의 1.22 nF 외부 Capacitor 방전과 400 V의 10 nF 외부 Capacitor 방전을 비교하였다. 방전 시 전압파형과 전류파형은 서로 다르지만 소비된 방전에너지는 340 ${\mu}J$로 동일하다. ICCD camera와 Spectrometer를 이용하여 비교 분석을 실시하였다. 방전 image 및 Optical Emission Spectroscopy 분석을 이용하여 플라즈마의 온도, 밀도 등을 시간적, 공간적으로 분석하였다.

  • PDF

Partial Discharge Sensor Characteristics for Distriminating Location in Power Cable (전력 케이블의 부분방전 위치 추정용 센서 특성 연구)

  • Nam, S.H.;Shin, D.S.;Kwon, Y.H.;Lee, S.J.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.326-328
    • /
    • 2002
  • 본 논문에서는 케이블 내전압 시험 및 부분 방전 측정 시험에 사용될 수 있는 전구 차단 장치의 차단 기준에 큰 영향을 미치는 케이블 부분방전 센서의 특성에 관한 연구를 수행하였다. 특히, 부분방전 발생시 부분방전 발생 위치를 보다 정확하게 판별할 수 있는 센서의 종류 및 구조를 주파수 특성과 시간 특성을 함께 측정한 결과를 보고한다.

  • PDF

A developments of inexpensive GIS partial discharge diagnostic system using the 9 Channel UHF sensors (9채널 UHF 센서를 적용한 염가형 GIS 부분방전 진단 시스템 개발)

  • Kim, Hong-Seok;Oh, Jae-Hun;Hong, Jung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2021-2022
    • /
    • 2008
  • UHF기법을 적용한 GIS 부분방전 진단 시스템은 가스절연 개폐장치(GIS: Gas Insulated Switchgear) 내부에서 발생하는 부분방전 신호를 측정하여 부분방전 원인을 진단한다. 이러한 부분방전 진단 시스템은 부분방전 신호를 UHF 대역의 고주파/위상 영역에서 분석하여 Digital 신호로 변환하기 때문에 고가의 분석 장비가 필요하므로 시스템의 설치 및 유지 보수비용이 많다. 따라서 부분방전 진단 시스템의 설치에 대하여 대중화하기 어려우며 GIS의 이상 상태가 발생하기 전에는 측정 데이터의 활용이 미비하다. 본 논문에서는 이러한 부분방전 시스템의 설치비용을 절감하고자 센서의 측정을 시간별로 변경하여 측정하는 염가형 부분방전 진단 시스템의 구성에 대하여 기술하며 대용량 데이터의 관리 방안에 대하여 기술한다.

  • PDF

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF

Spectroscopy of Visible Light Emitted from Plasma Occurred by Pulse Discharge (펄스형 방전플라스마에서 발생하는 가시광선의 분광특성 연구)

  • Choi, Woon Sang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 1998
  • We investigated visible light radiated from Plasma focus device by time-resolved analyzed method and time-integrated analyzed method. Plasma focus consisted of two coaxial electrodes is a device that translated from electric energy of maximum 40 kV/20 kJ in capacitor banks into visible light by electric discharge. Spectral analysis is using Monochromator(f =0.5m). Time-resolved spectrum is analyzed with a oscilloscope the light pulse of constant wavelength and time-integrated spectrum does with densitometer the film which developed a constant range of wavelength. The optimum condition of visible emission was that the discharging voltage was 17kV and the gas pressure 0.5 torr Ar.

  • PDF

A study of amplification for discharge excited KrF excimer laser (방전여기 KrF 엑사이머 레이저증폭)

  • 김수경
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.9-12
    • /
    • 1990
  • 본 연구는 KrF 엑사이머 레이저 증폭을 하기 위하여 먼저 능동매질을 N도 사용하여 발전기와 증폭기의 시간적인 동기회에 주 목적을 두었고 안정한 증폭기의 출력을 얻기 위해 방전관 에너지의 5%를 예비전리로 최적화 시켰으며 방전에 사용되는 Spark Gap Switch의 내부 인덕턴스를 고찰하였다.

  • PDF

Analysis of discharge characteristic by variations of discharge time and ambient temperature in AC-PDP (방전 시간과 주위 온도변화에 따른 AC-PDP의 방전 특성 변화 분석)

  • Sim, Choung-Hwan;Kim, Hyun-Gyu;Kim, Yun-Gi;Cho, Sung-Yong;Park, Cha-Soo;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1429_1430
    • /
    • 2009
  • 본 연구에서는 7인치 샘플패널의 가속 Aging 실험을 통해 Aging time(24hr~529hr)변화에 따른 오방전 발생 Mechanism을 분석하고자 했다. 상온에서 Aging time변화에 따른 정마진, 휘도, Vt close curve를 측정 하였고 시간과 온도(고온: $70^{\circ}C$, 상온: $25^{\circ}C$, 저온: $-20^{\circ}C$)에 따른 Discharge time lag의 변화양상을 측정하였다. 그리고 Sustain pulse수의 조절을 통해 패널의 Priming 조건을 제어하면서 오방전 발생 확률을 수치적으로 측정하였다. 실험을 통해, 패널의 Aging time이 늘어남에 따라서 상판의 MgO층에서 Sputtering현상이 발생하여 MgO 잔재들이 하판의 형광체 표면을 덮는 등 방전 개시 전압의 변화가 오방전 발생에 주요한 원인임을 알 수 있었다.

  • PDF

Studies on High Speed Addressing Driving Scheme using the Priming Effect in Plasma Display Panel (하전 입자 효과를 이용한 Plasma Display Panel의 고속 구동 파형에 관한 연구)

  • Shin, Bhum-Jae;Park, Sang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.45-52
    • /
    • 2009
  • This study is related to the realization of high speed address driving method for Full-HD PDP. The new self-priming addressing(SPA) driving scheme was proposed to improve an address discharge time lag, which utilizes the priming effect maintaining the priming discharge during an address period. In this study, the basic characteristics of the priming ramp discharge were investigated and optimize the reset pulse and priming pulse. It is noted that the address discharge time lag is significantly improved from 1.2[${\mu}s$] to 0.8[${\mu}s$] when the slope of the priming ramp pulse is below 0.1[$V/{\mu}s$].