• Title/Summary/Keyword: 방사성

Search Result 10,156, Processing Time 0.038 seconds

Photocatalytic Oxidation of Arsenite Using Goethite and UV LED (침철석과 자외선 LED를 이용한 아비산염의 광촉매 산화)

  • Jeon, Ji-Hun;Kim, Seong-Hee;Lee, Sang-Woo;Kim, Soon-Oh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Arsenic (As) has been considered as the most toxic one among various hazardous materials and As contamination can be caused naturally and anthropogenically. Major forms of arsenic in groundwater are arsenite [(As(III)] and/or arsenate [(As(V)], depending on redox condition: arsenite and arsenate are predominant in reduced and oxidized environments, respectively. Because arsenite is much more toxic and mobile than arsenate, there have been a number of studies on the reduction of its toxicity through oxidation of As(III) to As(V). This study was initiated to develop photocatalytic oxidation process for treatment of groundwater contaminated with arsenite. The performance of two types of light sources (UV lamp and UV LED) was compared and the feasibility of goethite as a photocatalyst was evaluated. The highest removal efficiency of the process was achieved at a goethite dose of 0.05 g/L. Based on the comparison of oxidation efficiencies of arsenite between two light sources, the apparent performance of UV LED was inferior to that of UV lamp. However, when the results were appraised on the basis of their emitting UV irradiation, the higher performance was achieved by UV LED than by UV lamp. This study demonstrates that environmentally friendly process of goethite-catalytic photo-oxidation without any addition of foreign catalyst is feasible for the reduction of arsenite in groundwater containing naturally-occurring goethite. In addition, this study confirms that UV LED can be used in the photo-oxidation of arsenite as an alternative light source of UV lamp to remedy the drawbacks of UV lamp, such as long stabilization time, high electrical power consumption, short lifespan, and high heat output requiring large cooling facilities.

Home Range Size and Habitat Environment Related to the Parturition of Roe Deer at Warm-Temperate Forest in Jeju Island Using GPS-CDMA Based Wildlife Tracking System (GPS와 CDMA를 이용한 난대림의 출산 전후 암노루 행동권 및 서식환경 조사)

  • Kim, Eun-Mi;Kwon, Jin-O;Kang, Chang-Wan;Song, Kuk-Man;Min, Dong-Won
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.2
    • /
    • pp.65-74
    • /
    • 2013
  • A research program for the roe deer (Capreolus pygargus) has been set up at the Jeju Experimental Forest of Warm-temperate and Subtropical Forest Research Center in Jeju Island. To explore the home range size and habitat environment, 3 males and 3 females have been captured and released with GPS-CDMA based telemetry since 24th April 2012. Among them 2 females were captured at Hannam Forest of Seoguipo, were pregnant and monitored by the tracking system. There are significantly different patterns in behavior around the parturition. After parturition they show recurrence behavior toward one point in the forest, while they have irregular patterns in moving before. To calculate the home range size, the MCP (minimum convex polygon) and Kernel Method are applied through the extension of ESRI ArcView GIS 3.2a. The pregnant female captured 9th May 2012 has the size of MCP=67ha and Kernel 95%=0.5ha and the pregnant female captured 12th July 2012 has the size of MCP=82ha and Kernel 95%=0.9ha. Although a fawn could move immediately just after the birth likely others to avoid any risks, they stay at very narrow space significantly, and the size become wider when more time goes by. Furthermore, they mainly have a home range away from human activity area such as forest tracking roads. The habitat environment for the parturition is summarized as 40years old cryptomeria forests with new sprouting shrubs for foods, which are the controlled forest through the thinning and removing shrubs 2 years ago. This means that forest works could cause positive results for the parturition and survival of young. The period of parturition is earlier than highland in Jeju Island, the size of home range is narrower than other countries, and the habitat environment of the shelter for a fawn is similar to previous research in other countries.

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.

Difference in Isoproterenol-Stimulated Cyclic AMP Levels of Lymphocytes between the Subgroups of Depressive Disorders (우울장애 아형간에 Isoproterenol 자극후 임파구 Cyclic AMP Levels의 차이)

  • Bahk, Won-Myong;Jeon, Yang-Whan;Kim, Kwang-Soo;Sung, Yang-Sook
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.46-50
    • /
    • 1996
  • This study was designed to examine the basal cyclic AMP levels and the $10^{-5}mol/L$ isoproterenol-stimulated cyclic AMP levels of lymphocytes, by which ${\beta}$-adrenoceptor function was shown, between to normal controls and 17 drug free patients(8 major depresive patients and 9 dysthymic patients), who were diagnosed by DSM-III-R. The severity of depression was assessed by Hamilton Rating Scale for Depression (HDRS). Cyclic AMP levels were measured by radioimmunoassay(double antibody). The results were as follows ; 1) HDRS score was significantly higher in major depressive patients($41.8{\pm}4.6$) than in dysthymic patients($24.0{\pm}4.2$)(p<005). 2) There was no Significant difference in basal cyclic AMP levels among normal controls($3.9{\pm}1.7pmol/10^6cells/10min$), major depressive patients($2.1{\pm}0.5pmol/10^6cells/10min$), and dysthymic patients($3.9{\pm}1.8pmol/10^6cells/10min$). 3) There was significant difference in net cyclic AMP levels($10^{-5}mol/L$ isoproterenol-stimulated cyclic AMP levels minus basal cyclic AMP levels) among normal controls($16.5{\pm}6.0pmol/10^6cells/10min$), major depressive patients($3.0{\pm}1.4pmol/10^6cells/10min$), dysthymic patients($10.9{\pm}4.4pmol/10^6cells/10min$)(p <005). 4) The net cyclic AMP levels were significantly correlated with HDRS scores in major depressive patients(${\gamma}=-0.8^6$, p<0.05), but not in dysthymic patients(${\gamma}=0.43$, p=0.25). In conclusion, we suggested that the dysthymic disorder might differ from the molar depressive disorder not only in the severity of depressive symptoms but also in ${\beta}$-adrenergic responsiveness of lymphocytes, which was regarded as a biological marker of depressive disorder.

  • PDF

Radiotherapy Incidents Analysis Based on ROSIS: Tendency and Frequency (ROSIS 자료 기반 방사선 사고 사례 분석 : 경향과 빈도)

  • Koo, Jihye;Yoon, MyongGeun;Chung, Won Kuu;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.298-303
    • /
    • 2014
  • In this study, we examine the trends and types of incidents frequently occur during radiation therapy by using the data from the radiation oncology safety information system (ROSIS), according to discovery method explores the development direction of future research accident cause factor control method. This study was carried out analysis of incident data in ROSIS nearly 1163 cases in last 11 years from 2003 to 2013. We categorized into treatment methods, found the time, discoverer of occupations and finding ways to analyze the data. Then, we calculate the percentage and the classification for each item. About 1163 cases of incident cases including the near miss cases, external radiation therapy, brachytherapy and other were 97%, 2% and 1%. In the case was improperly planned dose delivery was 44% (497 cases) which 429 cases (86%) was found before 3 fractions and 13 cases were found after 11 fractions. The investigation was found to be distributed in various a found times. Approximately 42% of found time was during treatment and 29% of patients were found the problem during inspection chart. Occupation to discover the most radiation accidents was the radiation therapist (53%) who works in treatment room. Among 1163 incidence cases, 24% cases were found the accident before the treatment, therefore most of accident were found after of during the treatment (70%, 813 cases). This trend is acquired through ROSIS analysis, is expected to be not significantly different in the case of Korea, so it is necessary more diverse and systematic research for the prevention and early detection by using the ROSIS data.

Methodologies for Enhancing Immersiveness in AR-based Product Design (증강현실 기반 제품 디자인의 몰입감 향상 기법)

  • Ha, Tae-Jin;Kim, Yeong-Mi;Ryu, Je-Ha;Woo, Woon-Tack
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.2 s.314
    • /
    • pp.37-46
    • /
    • 2007
  • In this paper, we propose technologies for enhancing the immersive realization of virtual objects in AR-based product design. Generally, multimodal senses such as visual/auditory/tactile feedback are well known as a method for enhancing the immersion in case of interaction with virtual objects. By adapting tangible objects we can provide touch sensation to users. A 3D model of the same scale overlays the whole area of the tangible object so the marker area is invisible. This contributes to enhancing immersion. Also, the hand occlusion problem when the virtual objects overlay the user's hands is partially solved, providing more immersive and natural images to users. Finally, multimodal feedback also creates better immersion. In our work, both vibrotactile feedback through page motors, pneumatic tactile feedback, and sound feedback are considered. In our scenario, a game-phone model is selected, by way of proposed augmented vibrotactile feedback, hands occlusion-reduced visual effects and sound feedback are provided to users. These proposed methodologies will contribute to a better immersive realization of the conventional AR system.

Evaluation on Management of Unified Health Subcenters (통합보건지소 운영 평가)

  • Kang, Pock-Soo;Lee, Kyeong-Soo;Hwang, Tae-Yoon;Kim, Chang-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • Objectives: This study is designed to suggest the health service goals necessary for providing the more efficient services relevant to the requests of the community, through the evaluation on the operating status of the unified health subcenters. Methods: We visited total 5 unified health subcenters comprising 3 ones located in Gyeongsangbuk-do and 2 ones located in Gyeongsangnam-do from December 2000 to January 2001, and interviewed about the pre- and post-unified status related to manpower, facilities, equipment, medical service and health service quality, and the problems and improvement plans of the unified management. Results: According to the evaluation on the manpower before and after the unification of the health subcenters, the total employees increased by 2.8 persons on average from 6.8 to 9.6 persons in the investigated subjects. The numbers of doctors, dentists and nurses were almost the same as before. There were no clinical pathologic technician and radiological technician before but they were appointed to duty in 3 unified health subcenters later. The unification of the health subcenters has produced slight increases in the frequency of the medical service and dental treatment and considerable increases in that of the physical therapy and laboratory tests. In relating to the changes of the health service, the cases of visiting health care and ambulatory medical service, and the total number of health education participants were greatly increased after the unification. The number of cases undergoing the vaccination and cervical cancer screening was similar to that of the pre-unification while the patient number of the registration to hypertension or diabetes showed a tendency to increase a little. Since the unification of the health subcenters, the frequency of laboratory tests has been increased, but the quality of health service has not been improved yet. Nevertheless, the unification seems to be positive according to the result of the great improvement in visiting health care, ambulatory medical service and health education service. The problems of the unification of the health subcenters were indicated in indefiniteness of the service details between the workers; excessively large building hard to be effectively managed; insufficient medical instruments, inappropriation of working expenses, lack of professional training for the health education, etc. Conclusions: For further active functions of the unified health subcenters, the minimal allocation basis to appoint doctors, nurses and administrative workers to do the duty should be differentiated from the basis for a health subcenter, and the fundamental instruments needs to be expanded to improve the quality of the medical service and visiting health care service. Moreover, the unified health subcenter needs to have definite service details between the workers, and should improve the working efficiency through the development of service-related guidelines.

  • PDF

Differences in Thrombolytic Effects in Accordance with Dosing-regimens of Tissue-type Plasminogen Activator in Experimental Pulmonary Embolism (실험적 폐색전증에서 조직형플라스미노겐활성체의 투여방법에 따른 혈전용해효과의 차이)

  • Chung, Hee-Soon;Kim, Ho-Jung;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.123-134
    • /
    • 1993
  • Background: Tissue-type plasminogen activator is a physiologic activator, which has high affinity for fibrin and is activated by fibrin. Because of these properties, t-PA has the potential to induce effective thrombolysis without producing a systemic lytic state. In practice, however, therapeutically efficacious doses of t-PA has been associated with the development of a systemic lytic state. As experience with t-PA has accumulated, it has suggested that the fibrin selectivity is influenced by the dose and duration of t-PA infusion, and many studies have performed in an attempt to optimize the duration of t-PA regimen. Methods: This study was designed to assess the thrombolytic efficacy of t-PA and the differences of two dosing regimens of t-PA (infusion of 1 mg/kg t-PA over 15 or 180 minutes) in a canine model of pulmonary embolism, induced by injection of radioactive autologous blood clots. By continuously counting over both lung fields with a external gamma counter, we correlated rate and extent of pulmonary thrombolysis with corresponding pulmonary hemodynamics in addition to the gas analyses of arterial and mixed venous blood. Results: 1) While total clot lysis was similar ($36.2{\pm}3.3%$ and $39.6{\pm}2.3%$ respectively, p>0.05) when t-PA was infused over 15 or 180 minutes, the rate of lysis during infusion was markedly increased with the shorter infusion ($81.4{\pm}16.8%/hr$ vs $37.3{\pm}2.4%/hr$, p<0.05). 2) The duration of thrombolysis was $63.3{\pm}22.2$ minutes although t-PA was administered over 15 minutes, and it was only $148.5{\pm}14.0$ minutes in case of the infusion over 180 minutes (p<0.05). 3) The increased rate of thrombolysis with the shorter infusion was accompanied by a faster amelioration of cardiopulmonary impairment from pulmonary embolism (p<0.05). Conclusion: It is concluded that the shorter (15 minutes) infusion of t-PA is superior to the longer (180 minutes) infusion when the dose is equal, in consideration of the faster improvement in cardiopulmonary impairment from pulmonary embolism.

  • PDF

Radiographic Evaluation of Adenoidal Size and Assessment of Impedance Audiometry in Children (소아 인두편도의 방사선적 고찰 및 Impedance 청력검사 소견)

  • 김주일;김철우;이병희;천경두
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.2-41
    • /
    • 1981
  • Tonsillectomy and adenoidectomy are the most common operations in the ENT field. Recent emphasis on careful selection of patients for these procedures derives from concern for complications of surgery, as well as the immunologic and anatomic functions of tonsils and adenoids. Adenoidectomy can relieve nasopharyngeal airway obstruction caused by enlarge adenoids, and can prevent complications such as heart failure and recurrent or chronic otitis media. We researched 117 cases of tonsilloadenoidectomy patients and 266 patients having routine examination from March, 1979 to February, 1981, and described the A/N ratio derived from linear measurements of lateral radiographs of the nasopharynx. The results of Impedance Audiometry and X-ray films from 117 cases of T&A patients were compared: 1) The average A/N ratio by age groups for 266 cases of normal children showed: 0.508 for age group, 0 to 3 years old, 0.533 for age group, 4 to 6 years old, 0.524 for age group, 7 to 9 years old, 0.519 for age group, 10 to 12 years old, 0.507 for age group, 13 to 15 years old, 0.481 for age group over 15 years old. The peak value lies in the age group of 4 to 6 years old. The sex difference of A/N ratio was not significant. 2) The average A/N ratio by age groups from 117 cases of T&A patients showed: 0.709 for age group, 0 to 3 years old, 0.733 for age group, 4 to 6 years old, 0.693 for age group, 7 to 9 years old, 0.707 for age group, 10 to 12 years old, 0.620 for age group, 13 to 15 years old, 0.756 for age group over 15 years old. 3) Among the 117 cases of T&A patients, the average A/N ratio for 57 cases in normal tympanogram was 0.688 and the average A/N ratio for 60 cases in abnormal tympanogram was 0.705. 4) Among 57 cases in abnormal tympanogram: 6 cases (10.5%) showed 0.40-0.59 of A/N ratio, 44 cases (77.2%) showed 0.60-0.79 of A/N ratio, and 7 cases (12.3%) showed 0.80-0.99 of A/N ratio. 5) Among 117 cases of T&A patients, 3 of 15 cases showing A/N ratio under 0.6, and 67 of 102 cases showing A/N ratio over 0.6, had paranasal sinusitis.

  • PDF

Development of Program for Renal Function Study with Quantification Analysis of Nuclear Medicine Image (핵의학 영상의 정량적 분석을 통한 신장기능 평가 프로그램 개발)

  • Song, Ju-Young;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shinn, Kyung-Sub;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.89-99
    • /
    • 2001
  • Purpose: In this study, we developed a new software tool for the analysis of renal scintigraphy which can be modified more easily by a user who needs to study new clinical applications, and the appropriateness of the results from our program was studied. Materials and Methods: The analysis tool was programmed with IDL5.2 and designed for use on a personal computer running Windows. For testing the developed tool and studying the appropriateness of the calculated glomerular filtration rate (GFR), $^{99m}Tc$-DTPA was administered to 10 adults in normal condition. In order to study the appropriateness of the calculated mean transit time (MTT), $^{99m}Tc-DTPA\;and\;^{99m}Tc-MAG3$ were administered to 11 adults in normal condition and 22 kidneys were analyzed. All the images were acquired with ORBITOR. the Siemens gamma camera. Results: With the developed tool, we could show dynamic renal images and time activity curve (TAC) in each ROI and calculate clinical parameters of renal function. The results calculated by the developed tool were not different statistically from the results obtained by the Siemens application program (Tmax: p=0.68, Relative Renal Function: p:1.0, GFR: p=0.25) and the developed program proved reasonable. The MTT calculation tool proved to be reasonable by the evaluation of the influence of hydration status on MTT. Conclusion: We have obtained reasonable clinical parameters for the evaluation of renal function with the software tool developed in this study. The developed tool could prove more practical than conventional, commercial programs.

  • PDF