• Title/Summary/Keyword: 방사성

Search Result 10,211, Processing Time 0.045 seconds

Distribution and Mobility of Herbicide $^{14}C$-Molinate in a Rice-Paddy-Soil Lysimeter (벼 재배 Lysimeter 환경에서 제초제 $^{14}C$-molinate의 분포 및 이동성 평가)

  • Park, Byung-Jun;Kim, Chan-Sub;Park, Kyung-Hun;Park, Hyeon-Ju;Im, Geon-Jae;Choi, Ju-Hyeon;Shim, Jae-Han;Ryu, Gab-Hee
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.3
    • /
    • pp.172-182
    • /
    • 2006
  • This study was designed to assess molinate fate in the lysimeter by measuring the total radioactivity in the leachate, evolved $^{14}CO_2$, and $^{14}C$-residues in soil and rice plant. The amounts of applied $^{14}C$ in the leachate from the lysimeter for 20 weeks were 1.05% in 2.31 pore volume (217,465 mL) at the first and 0.34% in the second year, respectively. The amount of $^{14}CO_2$ evolved from the lysimeter accounted for 6.47% and 0.03% of applied $^{14}C$ in the first and second year. The $^{14}C$-activities in the soil layer of the lysimeter were distributed 18.0% (1st) and 13.3%(2nd) in the depth of 0 to 10 cm, 4.3 (1st) and 1.1% (2nd) in the depth of 10 to 20 cm. Most of the applied $^{14}C$ was detected in the top 20 cm soil layer. Total $^{14}C$ in rice plants grown at lysimeter were detected 11.46% of applied $^{14}C$. 11.11% in straw, 0.24% in brown rice grain, 0.08% in chaff and 0.03% in ears were distributed in the first year. Consequently, environmental fate of molinate using lysimeter simulating a paddy rice field were investigated 25.24% in soil, 11.64% in rice plant, 1.05% in leachate, 6.74% in evolved $^{14}CO_2$ and 0.02% in volatilized organic chemicals in the first year.

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

The Outcome of Conventional External Beam Radiotherapy for Patients with Squamous Cell Carcinoma of the Esophagus (식도의 편평상피세포암 환자에서 외부방사선치료의 결과)

  • Jang, Ji-Young
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: The best treatment for advanced esophageal cancer is chemoradiotherapy followed by surgery. In spite of the advance of multimodality therapy, most patients with esophageal cancer are treated with radiation therapy alone. This study reports the outcome of the use of conventional external beam radiotherapy alone for the treatment of esophageal cancer. Materials and Methods: Between January 1998 and December 2005, 30 patients with squamous cell carcinoma of the esophagus were treated with external beam radiotherapy using a total dose exceeding 40 Gy. Radiotherapy was delivered with a total dose of 44-60 Gy(median dose, 57.2 Gy) over $36{\sim}115$ days(median time, 45 days). Thirteen patients(43.3%) had a history of disorders such as diabetes, hypertension, tuberculosis, lye stricture, asthma, cerebral infarct, and cancers. Four patients metachronously had double primary cancers. The most common location of a tumor was the mid-thoracic portion of the esophagus(56.7%). Tumor lengths ranged from 2 cm to 11 cm, with a median length of 6 cm. For AJCC staging, stage III was the most common (63.3%). Five patients had metastases at diagnosis. Results: The median overall survival was 8.3 months. The survival rates at 1-year and 2-years were 33.3% and 18.7%, respectively. The complete response rate $1{\sim}3$ months after radiotherapy was 20%(6/30) and the partial response rate was 70%(21/30). Sixteen patients(53.3%) had an improved symptom of dysphagia. Significant prognostic factors were age, tumor length, stage, degree of dysphagia at the time of diagnosis and tumor response. Cox regression analysis revealed the aim of treatment, clinical tumor response and tumor length as independent prognostic factors for overall survival. Twenty-eight patients had local failure and another four patients had metastases. Three patients were detected with double primary cancers in this analysis. A complication of esophageal stricture was observed in three patients(10%), and radiation pneumonitis occurred in two patients(6.7%). Conclusion: The prognosis of esophageal cancer remains poor, in spite of advances in radiotherapy techniques. Radiotherapy is one of the main treatment modalities for the relief of dysphagia and treatment related complications are minimal. It is expected that the addition of chemotherapy or another systemic modality to radiotherapy will improve tumor control and increase the survival rate in advanced esophageal cancer.

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

Detection of HCV-RNA by Reverse Transcription Polymerase Chain Reaction Using Biotinylated and Radioiodinated Primers (역전사 중합효소 연쇄반응(RT-PCR)에 의한 HCV-RNA의 검출 : Biotin 및 방사성옥소 표지 Primer로 구성된 Kit의 이용)

  • Ryu, Jin-Sook;Moon, Dae-Hyuk;Cheon, Jun-Hong;Chung, Yoon-Young;Park, Hung-Dong;Chung, Young-Hwa;Lee, Young-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.220-226
    • /
    • 1994
  • This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.

  • PDF

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Isolation and Identification of Microorganisms Producing the Soy Protein-Hydrolyzing Enzyme from Traditional Mejus (전통메주로부터 대두단백질 가수분해효소 생산성 미생물의 분리 및 동정)

  • Kang, Min-Jung;Kim, Seong-Ho;Joo, Hyun-Kyu;Lee, Gap-Sang;Yim, Moo-Hyun
    • Applied Biological Chemistry
    • /
    • v.43 no.2
    • /
    • pp.86-94
    • /
    • 2000
  • In order to develop the enzymatic hydrolysis system concerned with taste and flavor, strains having the high hydrolyzing activity on the soy protein were selected from some traditional Mejus. Two molds and one bacterium producing enzymes which were different in character of hydrolysis were isolated and identified. Leucine and azodye enzyme activities of both M4 and M5 were relatively high among in the isolated molds. And, leucine enzyme activity of B16 was the lowest in the isolated bacteria. These strains were isolated as microorganisms having a dissimilar hydrolysis pattern on the soy protein by enzymatic reactions. Mold M4 on the culture solid media was mycelium colors of white and its sclerotia colors were changed from white to black. According to the result of slide culture, radial conidial head, subclavate vesicle, conidia of subglobose, stipes of uncolored with smooth walls and metula and phialides were existed. Because M4 was taxonomically similar to the characteristics of Aspergillus oryzae (ahlburg) species, M4 was identified and named as Aspergillus oryzae M4.Mold M5 showed white and black mycelium on the MEA medium. Mold M5 colony exhibited grayish-green color and have long(7 mm) sporangiophores at slide culture. Sporangia became brownish-gray and the wall of larger sporangia was broken to form small collars, and smaller sporangia were fomed continually from large basal membrane. Columella is globose and hyaline, and sporangiospores are ellipsoidal of small diameter$(80\;{\mu}m)$. Because M5 was taxonomically similar to the Mucor circinelloides of zygomycetes, M5 was was identified and named as Mucor circinelloides M5. Bacteria B16 colony was opaque white, circular and lobate, and had rod shaped endospore. B16 was found positive in stain, catalase, ${\beta}-glucosidse$ and V-P tests. B16 was found to utilize D-fructose, ${\alpha}-D-glucose$, maltose, D-mannose, D-raffinose, stachyose and sucrose. By the morphological and physiological results, the characteristics of B16 was thought to correspond to that of Bacillus megaterium. However, fatty acid composition was similar to Paenibacillus marcerans, requiring further study for the definite identification. Accordingly, Bacteria B16 was provisionally classified and named as Bacillus megaterium B16.

  • PDF

Applications of "High Definition Digital Climate Maps" in Restructuring of Korean Agriculture (한국농업의 구조조정과 전자기후도의 역할)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2007
  • The use of information on natural resources is indispensable to most agricultural activities to avoid disasters, to improve input efficiency, and to increase lam income. Most information is prepared and managed at a spatial scale called the "Hydrologic Unit" (HU), which means watershed or small river basin, because virtually every environmental problem can be handled best within a single HU. South Korea consists of 840 such watersheds and, while other watershed-specific information is routinely managed by government organizations, there are none responsible for agricultural weather and climate. A joint research team of Kyung Hee University and the Agriculture, forestry and Fisheries Information Service has begun a 4-year project funded by the Ministry of Agriculture and forestry to establish a watershed-specific agricultural weather information service based on "high definition" digital climate maps (HD-DCMs) utilizing the state of the art geospatial climatological technology. For example, a daily minimum temperature model simulating the thermodynamic nature of cold air with the aid of raster GIS and microwave temperature profiling will quantify effects of cold air drainage on local temperature. By using these techniques and 30-year (1971-2000) synoptic observations, gridded climate data including temperature, solar irradiance, and precipitation will be prepared for each watershed at a 30m spacing. Together with the climatological normals, there will be 3-hourly near-real time meterological mapping using the Korea Meteorological Administration's digital forecasting products which are prepared at a 5 km by 5 km resolution. Resulting HD-DCM database and operational technology will be transferred to local governments, and they will be responsible for routine operations and applications in their region. This paper describes the project in detail and demonstrates some of the interim results.

재래닭 생산물의 소비형태에 관한 조사연구

  • 한성욱
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 1998.04a
    • /
    • pp.51-86
    • /
    • 1998
  • $\bigcirc$ 재래닭 생산물의 소비 및 구매형태 등에 대한 조사에서 종합적인 결론은 최종 소비자의 응답자는 총 2,250명이었으며 연령, 성별, 직업, 거주지, 주거형태, 가족수, 소득분포등이 비교적 다양하게 분포되어 있다. 판매업소의 특성은 지역별, 매장면적, 업주연령, 성별, 경력등에서 매장위치는 약 60%가 농촌이고 관광지 21.3%, 도시 19.0%순이였으며 매장 면적은 10-30평이 66.9%, 경력은 3년이하 27.4%, 3-5년 22.7%, 5-10년 22.2%였다. $\bigcirc$ 재래닭고기의 소비형태에서 육류선호도는 쇠고기, 돼지고기, 닭고기 순이였으며 재래닭고기의 소비형태에서 전체 응답자의 64.4%가 먹어본 경험이 있었다. 주로 섭취시기는 74.5%가 여름철에 식구들과 같이 회식할 때 식사대용이나 부식용으로 섭취하였다. 소비자가 재래닭고기를 좋아하는 이유는 고기가 쫄깃쫄깃하여 씹는맛과 지방이 적으며 단백한 맛 때문에 독특해서 좋아한다고 하였으며, 싫어하는 이유는 너무 질기고 고기의 양이 너무 적다는 의견이 많았다. 선호하는 요리방법은 백숙, 삼계탕이었고 좋아하는 부위는 역시 다리부위였다. 재래닭고기의 섭취량에 대하여는 1회에 2인이 1마리를 먹는다가 36.4%, 3인이 1마리 31.8%로서 68.2%가 2-3인이 1마리를 먹는다고 하였으며, 가족구성원 중에는 가장이 제일 선호하는 것으로 나타났다. $\bigcirc$ 음식점에서 판매되는 요리한 재래닭의 1마리 가격에 대한 의견은 84.5%가 20,000원정도면 부담이 없이 먹겠다고 하였다. $\bigcirc$ 재래닭의 구입행동에서 구입주체는 주부였으며, 구입장소는 농.축협의 슈퍼와 정육점이었고 백화점과 재래닭 사육장에서 직접구입도 하고 있었다. 구입 동기는 가족들이 좋아하고 영양가를 생각한다가 62%였으며 구입정보는 주위사람의 권유로 구입하고 있었다. $\bigcirc$ 구입할 때 중점적으로 살펴보는 사항은 신선도와 순수재래종 여부, 위생상태였다. 한편 소비자가 언제나 구입할 수 없다는 의견이 85.2%나 되어 원활한 공급과 시장조성이 아직 정착되지 않고 있었다. $\bigcirc$ 현재 유통되고 있는 재래종닭은 소비자 대부분이 잡종으로 인식하고 있었으며, 재래종과 일반육계와의 구별은 깃털색, 피부색, 정강이색등 외관상으로 구별하고 있었다. 체중에 대한 반응은 너무 작다는 의견이었고, 식품으로의 인식도는 비교적 고급식품으로 인식하고 있다. $\bigcirc$ 재래종닭고기의 브랜드화에 대한 견해는 젊고 소득이 높은 계층에서 브랜드화의 필요성을 강조하고 있다. $\bigcirc$ 재래종달걀의 소비형태는 대부분의 소비자가 좋아하였으나 아직 먹어보지 못한 응답자가 많았다. 재래종달걀의 맛에 대해서는 고소하고 독특하여 차별성을 느끼고 있었다. $\bigcirc$ 재래종달걀의 구입장소는 계란판매점(축협.농협), 슈퍼, 백화점, 재래닭 사육 농장등 다양하였으며 포장단위는 10개를 가장 선호하였고, 포장재료는 종이, 플라스틱, 짚의 순으로 좋아하였다. $\bigcirc$ 달걀의 가격은 200원정도를 적정하다고 하였으며, 크기는 (평균 52g)는 가장 적당하다고 인식하고 있으며, 난각색은 대부분의 응답자가 갈색을 선호하였다. $\bigcirc$ 재래종달걀의 구입시 애로사항은 믿을수 없고, 구입장소를 몰라서, 값이 싸다 등이었고, 앞으로 신뢰할 수 있고 위생적인 생산 및 유통체계가 확립될 경우 더 많이 소비하겠다는 의견이었다. $\bigcirc$ 재래닭 판매업소(식당)의 판매형태는 66.7%인 대부분의 업소가 잡종과 개량종 유색닭을 판매하고 있었으며, 1개 업소에서 1일 판매수수는 5-10수의 영세한 판매형태였고, 계절적으로는 여름철에 대부분을 판매하였다. $\bigcirc$ 식당에서 판매하는 재래닭고기의 요리 종류는 주로 백숙이었고, 삼계탕, 닭볶음도 있었으며, 요리된 재래닭 1마리 가격은 20,000원 이상이었으며, 20,000원이하로 판매하는 잡종이 많았다. $\bigcirc$ 재래닭 판매업소에서 재래닭을 구입하는 방법은 재래닭 사육농장에서 1회에 수십마리 구입하여 판매업소의 간이 사육장에서 기르면서 판매하는 업소가 49.6%, 도계된 재래닭을 구입하여 판매하는 업소 26.9%, 직접 재래닭을 사육하면서도 도계하여 판매하는 업소가 21.7%였다. 판매업소에서의 재래닭 사육기간은 90일 이상이었으며 대부분의 업주는 야산에서 방사한 것을 좋게 생각하고 있었다.

  • PDF

Usefulness of $^{18}F$-FDG PET/CT in Locoregional Recurrence of Differentiated Thyroid Cancer: Comparison PET/CT to PET and Neck Ultrasonography for Biopsy-proven Lesions (갑상선유두암 재발 진단에서 $^{18}F$-FDG PET/CT와 경부초음파검사 병용의 유용성: PET, 경부초음파검사 그리고 혈청 티로글로불린 (thyroglobulin)의 비교)

  • Kim, Kun-Ho;Shong, Min-Ho;Seo, Young-Duk;Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.411-420
    • /
    • 2009
  • Purpose: The aim of this study was to investigate the usefulness of $^{18}F$-FDG PET/CT with neck ultrasonography (neck US) in patients with recurrent, papillary thyroid cancer. Material and methods: This retrospective study (December 2006 to April 2008) enrolled sixty-one patients (ninety-one lesions) who underwent high-dose $^{131}I$-ablation therapy after total thyroidectomy, and evaluated recurred papillary thyroid cancer. All lesions were confirmed by histopathology and compared histopathologic findings to PET, PET/CT, and neck US findings. Results: In sixty-one patients (57 women, 4 men; age range, 24-81 years, mean 49 years; 61 papillary carcinomas), the sensitivity, specificity, accuracy of $^{18}F$-FDG PET/CT was 87.2%, 64.0%, 78.1% on a patient basis and 92.3%, 66.7%, 80.9% on a lesion basis, respectively. The sensitivity, specificity, accuracy of $^{18}F$-FDG PET was 71.8% (p=0.03), 59.0% (p=1.00), 67.2% (p=0.03) on a patient basis and 78.8% (p<0.01), 64.1% (p=1.00), 72.5% (p=0.02) on a lesion basis, respectively. The sensitivity, specificity, accuracy of neck US was 71.1% (p=0.07), 52.2% (p=0.75), 63.9% (p=0.05) on a patient basis and 71.2% (p<0.01), 61.5% (p=1.00), 67.0% (p=0.06) on a lesion basis, respectively. Combined $^{18}F$-FDG PET/CT with neck US improved the sensitivity, specificity, accuracy to 94.7% (p=0.50), 82.6% (p=0.13), 90.2% (p=0.03) on a patient basis and 96.2% (p=0.50), 89.7% (p<0.01), 93.4% (p<0.01) on a lesion basis, respectively. Conclusion: $^{18}F$-FDG PET/CT demonstrated significantly higher sensitivity than neck US for the detection of recurred papillary thyroid cancer lesions. Furthermore, combined $^{18}F$-FDG PET/CT with neck US showed more improved sensitivity, specificity, accuracy for diagnosis of recurrent papillary thyroid cancer.