• Title/Summary/Keyword: 방사선 투과율

Search Result 75, Processing Time 0.027 seconds

Study on electrical properties of photoconductors for radiation detector application based on liquid crystal (액정 기반 방사선 검출기 적용을 위한 광도전체의 전기적 특성 연구)

  • Kang, Sang-Sik;Choi, Young-Zoon;Lee, Mi-Hyun;Kim, Hyun-Hee;No, Si-Chul;Cho, Kyu-Suck;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.27-30
    • /
    • 2010
  • A X-ray optical modulator measures x-ray dose using optical transmissivity ratio change of the liquid crystal cell. To apply in this optical modulator, we made photoconductor films and compared electrical properties of this films in this study. Photoconductors are deposited on ITO glass with $200{\mu}m$ using the percipitation method and print method. I-V test was conducted to alalyze electrical properties of this films and measured darkcurrent and SNR was acquired using the measured dark current and sensitivity. As a result of this measurements, $HgI_2$ film made by precipitation method is lower(about 40%) darkcurrent than $HgI_2$ films made by precipitation method and sensitivity is two times greater than print method. And we knew that $HgI_2$ films were also 10~25 times greater SNR at $1v/{\mu}m$ than $PbI_2$, PbO, CdTe film made by precipitation method. This results suggest that $HgI_2$ films made by precipitation method has improved characteristics of x-ray dose meter by applying in x-ray optical modulator.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

The Measurement of $^{99m}Tc-DTPA$ Pulmonary Clearance in Normals, Asymptomatic Smokers and Diabetic Patients (정상 성인, 무증상 흡연자, 당뇨병 환자에서 $^{99m}Tc-DTPA$ 폐제거율의 측정)

  • Kim, In-Ju;Kim, Seong-Jang;Kim, Yong-Ki;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.266-275
    • /
    • 1998
  • Purpose: We measured pulmonary epithelial permeability by $^{99m}Tc-DTPA$ radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate $^{99m}Tc-DTPA$ radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. Materials and Methods: We performed $^{99m}Tc-DTPA$ radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) was calculated, then compared with the result of chest radiography and pulmonary function test. Results: Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiopathy were significantly older (p<0.05). The $T_{1/2}$ of normal subjects and asymptomatic smokers were significantly different ($65.2{\pm}23.7min$ vs $39.6{\pm}9.8min$, p<0.05). For diabetic patients with microangiopathy, the $T_{1/2}$ was $90.5{\pm}46.5min$ and significantly delayed when compared with those of normals and asymptomatic smokers (p<0.05). However, the $T_{1/2}$ of diabetic patients without microangiopathy, $70.0{\pm}12.7min$, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the $T_{1/2}$ and spirometric parameters including DLco, FVC, $FEV_1,\;FEV_1/FVC$ (%) and $FEF_{25-75%}$ in all subjects, and between the $T_{1/2}$ and duration of diabetes ;in diabetic patients. Conclusion: Eventhough the influence of age can't be excluded, delayed $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy.

  • PDF

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

옥수수 전분 추출공정 및 물성개선을 위한 방사선의 이용연구

  • 강일준;이수정
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 1994.07a
    • /
    • pp.15-16
    • /
    • 1994
  • 옥수수 전분의 추출공정 개선 연구의 일환으로 메 밀 찰옥수수에 0-10 kGy범위의 감마선을 조사한 후 전분 추출시험과 추출전분의 이화학적 특성을 펴가하였다. 적정선량 범위의 감마선조사는 전분추출을 위한 침지시간을 기존 50시간에서 40시간으로 단축 시킬 수 있었으며, 환경기준 물질인 옥수수침지액(아황산용액)의 농도를 기존 0.8-1.2% 에서 0.2%로 크게 감소시킬 수 있었다. 또한 옥수수전분 추출액에 있어서 감마선 조사된 메옥수수와 찰옥수수는 비조사군에 비해 10-30% 이상의 추출율 증대효과를 나타내었다. 추 전분의 이화학적 특성시험에있어서는 두 시료 모두 감마선조사에 의해 alkaili number와 광투과도가 크게 증가 하였으며, 물 결합능력 및 swelling power는 다소 감소하는 경향이었다.전분의 색도는 조사군과 비조사군 사이에 유의적인 차이가 없었다. 효소반응 시험에서는 감마선 조사량이 증가함에 따라 효소반응 생성물인 포도당과 환원당 함량이 크게 증가하였다. Amylograph에 의한 물성시험에서는 감마선조사에 의해 전분호화액의 점도는 감소되었고, 그 경향은 메옥수수보다 찰옥수수에서 더욱 현저하였다. 또한 감마선의 이용은 옥수수 전분의 breakdown ratio 및 setback ratio를 향상시킬 수 있어 식품가공에서 전분의 고존도 사입 가능성을 시사하였다. 시사하였다.

  • PDF

Design of Double Layer Shielding Structure using Eco-friendly Shielding Materials (친환경 차폐물질을 이용한 이중구조 차폐체의 설계)

  • Park, Ji Koon;Choi, Il Hong;Park, Hyung Hoo;Yang, Sung Woo;Kim, Kyo Tae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.559-563
    • /
    • 2016
  • Recently, a barium(Ba) and an iodine(I) being studied as a conventional lead(Pb) alternatives of shielding material has excellent shieding rate, but the characteristic x-ray photons in the energy range near 30 keV line is released. In this study, with bismuth oxide(BiO) coupled barium sulfate($BaSO_4$) double layer, transmitted spectra, shieding rates and relative weighting rates were evaluated to validate the applicability of eco-friendly double layer shieding structure using monte carlo simulations as a prior study. From the evaluation results, in 0.4mm and 0.5mm thickness of BiO layers coupled with top 0.1mm-$BaSO_4$ layer, the shieding rate showed 1.9% and 3.9% higher than 0.6mm thickness of Pb single layer, respectively. In addition, the relative weight also 28% and 34.5% lower than 0.6mm-Pb in 0.4mm and 0.5mm thickness of BiO layers coupled with top 0.1mm-$BaSO_4$ layer.

Development of Liquid Crystal Optic Modulation Based X-ray Dosimeter by Using CdS Sensor (CdS 센서를 이용한 액정 광변조 X-선 검출 시스템 개발)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Kim, Hyun-Hee;Cho, Chang-Hoon;Park, Jun-Hong;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.357-361
    • /
    • 2011
  • In this study, the liquid-crystal optical modulation X-ray detection system using a CdS which is a family of II-IV compound semiconductor was proposed. The system consist of the detector, the signal processing part, the liquid-crystal driving parts, microcontroller, and I/O parts, and was designed to be suitable for miniaturization and portable. In addition, the system can measure a wide range X-ray by using the detecting range selection. In order to evaluate the performance of the proposed system, the CdS sensor's output characteristics were confirmed in accordance with changes of dose, and excellent correlation was determined. And also, the optical penetration ratio was discussed in accordance with changes of the applied voltage by measuring the change of the liquid-crystal in accordance with changes of the applied voltage. Through these results, the characteristics of the liquid-crystal optical modulation system such as the excellent reproducibility and the noise immunity were confirmed. And we considered that the CdS cell-based liquid-crystal optical modulated portable X-ray detection system could be applied to compact, low-cost, portable system.

Spatial Distribution of Macropore Development on a Hillslope (소유역의 사면에서의 대공극발달의 공간적 분포)

  • Kwak, Yong-Seok;Kim, Sang-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.825-830
    • /
    • 2007
  • 사면에서 발생되는 강우유출과정에 기여하는 대공극의 영향은 그 중요성에도 불구하고 잘 알려져 있지 않다. 특히 대공극의 공간적분포특상에 대한 현장측정은 이뤄지지 않았다. 본 연구의 실험지역은 경기도 포천시 광릉수목원에 있는 작은 소유역이다. 이 지역의 정밀한 측량을 하여 수치고도모형(DEM)을 얻었다. 이 수치고도모형을 바탕으로 수치지형분석을 통해 흐름선을 파악하여 총 20지점을 선정하였다. 각 지점에서의 대공극을 통한 수직적인 유동들은 장력침투계를 사용하여 지표면아래 깊이 10cm에서 측정하였다. 공간적 토양의 특성분포를 파악하기 위해 각 지점에서의 체적밀도와 점토함량을 조사하였다. 토양수분의 공간적 분포 특성은 TDR(Time Domain Reflectometry)방식인 TRASE를 이용하여 토양수분 값을 얻었다. 이러한 다양한 공간적 특성들은 대공극발달의 공간적 분포특성을 파악하는 중요자료가 된다. 소유역을 크게 기여사면 면적을 기준으로 상부, 중부, 하부로 나누어 대공극의 유효 공극율과 대공극흐름율을 계산하였다. 상부에서의 유효 대공극율의 평균값과 변동계수는 각각 4.3%, 42.1%이고, 대공극흐름율의 평균값과 변동계수는 각각 45.0%, 26.6%이다. 중부에서는 유효 대공극율의 평균값과 변동계수는 6.8%, 37.3%이고, 대공극흐름율의 평균값과 변동계수는 56.2%, 14.4% 이다. 그리고 하부에서의 유효공극율의 평균값과 변동계수는 12.5%, 58.3% 이고 대공극흐름율의 평균값과 변동계수는 64.5%, 24%이다. 이는 유효 대공극율과 대공극흐름율의 비율은 기여사면 면적이 증가할수록 증가하였다. 이는 대공극을 통한 물 이송 능력이 원두부로 갈수록 증가한다는 것을 보여주고 있다.e, taurine, methionine, phenylalanine은 함량(含量)이 적었다. 5. 일건(日乾)중 총유리아미노산의 변화(變化)는 생시료(生試料)의 경우 2,041.2 mg%였으나 1일(日) 건조(乾燥) 후는 1,784.0 mg%로 감소(減少)하다가 그 이후 계속 증가(增加)하여 20일(日) 건조(乾燥) 후는 5,277.0 mg%였다. 6. 일건(日乾)중 leucine, isoleucine, valine은 대체로 증가(增加)하는 경향(傾向)을 나타내었으나 aspartic acid, proline, taurine은 대체로 감소(減少)하는 경향(傾向)을 나타내었다. 436.59mg%로 가장 많았고 군유산(軍有山) 차엽(茶葉)이 146.94mg%로 가장 적었으며 일반차엽(一般茶葉)의 평균치(平均値)는 264.59mg%, 용장(龍欌) 차엽(茶葉)이 223.10mg%, Yabukita 차엽(茶葉)이 256.49mg%였다. 7) 이상(以上)의 결과(結果)를 종합(綜合)할 때 용장(龍欌) 차엽(茶葉)은 일반차엽(一般茶葉)과 형질(形質) 뿐만 아니라, 성분(成分)도 다르므로 품종(品種)이 다른 수종(樹種)으로 추정(推定)되며 와운(臥雲) 차엽(茶葉)은 일반차엽(一般茶葉)과 형질(形質)은 다르나 성분상(成分上)의 비슷한 점으로 보아 동일계통(同一系統)의 변이(變異)된 대엽종(大葉種)으로 추정(推定)된다.5(${\pm}0.77$0.77) % 의 오차로 크게 감소하였다. 결론: 방사선이 통과하는 경로에 불균질조직인 폐가 존재할 경우에도 불균질조직에 대하여 조직의 밀도를 이용하여 보정하는 방법을 사용하여 투과선량으로부터 종양선량을 계산할 수 있음을 알 수 있었다.X>로 평균$43.26{\m

  • PDF

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

Comparative Evaluation of the Survival Rates of Zirconia Crown and Stainless Steel Crown for Proximal Caries in Primary Molars: a Retrospective Study (유구치 인접면 우식증 수복 시 지르코니아 전장관과 기성금속관의 생존율 비교 평가: 후향적 연구)

  • Gahui Jeong;Nanyoung Lee;Hyewon Shin;Suhyun Park;Myeongkwan Jih
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.3
    • /
    • pp.307-317
    • /
    • 2023
  • Due to increasing demand for aesthetics, zirconia crowns have become a popular choice for treating primary molars. However, there is limited literature available comparing the survival rates of zirconia crowns with those of other restorative materials. The objective of this study was to compare the 36-month survival rates of zirconia crowns and stainless steel crowns for proximal caries, as well as to analyze failure types associated with each crown type. Electronic medical records and radiographs of 1,061 primary molars from 498 patients treated with 2 types of prefabricated crowns at Chosun University Dental Hospital and 2 private dental clinics between 2017 and 2019 were collected and analyzed. The survival rate of zirconia crowns was found to be lower compared to that of stainless steel crowns. Regarding the groups without pulp treatment, the survival rate of stainless steel crowns was significantly higher than that of zirconia crowns. However, in the groups that received pulp therapy, no significant difference in the survival rates was observed between the two preformed crowns. Notably, abnormal root resorption or periapical lesions were identified as the primary cause of restorative failure in stainless steel crowns, whereas loss of restoration was the predominant cause in zirconia crowns. This study holds valuable implications for clinicians when selecting preformed crowns for primary molars.