• Title/Summary/Keyword: 방사선 투과도

Search Result 658, Processing Time 0.021 seconds

Affinity Membrane의 개발

  • Kim, Min
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.04a
    • /
    • pp.12-15
    • /
    • 1993
  • 방사선 graft 중합법을 이용하여, microfiltration hollow fiber(MF)에 affinity ligand로서 소수성 아미노산 (tryptophan)을 고정하였다. affinity막에 압력차를 주어 막의 안쪽으로 부터 바깥쪽으로 단백질 용액을 투과시키면서, 단백질의 흡착 성능을 알아보았다. affinity막이 확산이동 저항이 없는 우수한 분리 기능 재료인 것을 나타내었다.

  • PDF

Enact of Glutathione(GSH/GSSG) Contents of Fermented Ginseng on the ${\gamma}$-irradiated Liver of Mice (감마선을 조사한 생쥐 간에서 발효인삼이 Glutathione 함량에 미치는 영향)

  • Ko, In-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.29-34
    • /
    • 2006
  • Purpose: The radioprotective effects of white and fermented ginseng on liver damage induced by $^{60}Co\;{\gamma}$-ray were investigated. Materials and Methods: To one group of ICR male mice were given white(150 mg/kg/day for 7 days, orally) and fermented ginseng(150 mg/kg/day for 7 days, orally) before $^{60}Co\;{\gamma}$-ray irradiation. To another group were irradiated by 5 Gy(1.01 Gy/min) dose of $^{60}Co\;{\gamma}$-ray. Contrast group were given with saline(0.1 mL). The levels of reduced(GSH) and oxidized(GSSG) glutathione in liver tissue were measured. Results: In the fermented(150 mg/kg) and white ginseng(150 mg/kg) groups than irradiation group, the GSH levels were significantly increased, but the GSSG levels were significantly decreased. The ratio of GSSG/total GSH was significantly decreased in the fermented(150 mg/kg) and white ginseng(150 mg/kg) groups than irradiation group. Conclusion: In the fermented(150 mg/kg) groups than white ginseng(150 mg/kg) groups the GSH levels were significantly increased. The radioprotective effects of fermented(150 mg/kg) groups than white ginseng(150 mg/kg) groups were increased.

  • PDF

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds (배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교)

  • Yang, Jin-Wook;Cho, Kap-Ho;Nam, Mun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.585-594
    • /
    • 2022
  • The detector for digital radiography testing, which is currently mainly used, consists of a detector with a flat structure, making it impossible to fully adhere to the digital radiography testing of the test object with curvature. In this study, a curved panel detector capable of adhering to curvature was fabricated to improve the quality of the digital image during the digital radiography testing of piping welds at industrial sites, and digital radiography images using flat and curved panel detectors were obtained for 6in pipes with different nominal thickness. As a result of the experiment, it was confirmed that the flat panel detector does not fully adhere to the pipe, resulting in a gap between the outer part of the pipe and the detector, resulting in a difference in the unsharpness and diffusion of the digital image. On the other hand, it was confirmed that the curved panel detector minimizes the gap between the pipe outer part and the detector, so that digital image diffusion is less than that of the flat panel detector. The higher the confidence of the image, the lower the quality and error in reading, so it is believed that higher quality images can be obtained than conventional flat panel detectors when using detectors that can be closely attached to the inspection object.

Usefulness of Permeability Map by Perfusion MRI of Brain Tumor the Grade Assessment (뇌종양의 등급분류를 위한 관류 자기공명영상을 이용한 투과성영상(Permeability Map)의 유용성 평가)

  • Bae, Sung-Jin;Lee, Joo-Young;Chang, Hyuk-Won
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.325-334
    • /
    • 2009
  • Purpose : This study was conducted to assess how effective the permeability ratio and relative cerebral blood volume ratio are to tumor through perfusion MRI by measuring and reflecting the grade assessment and differential diagnosis and the permeability and relative cerebral blood volume of contrast media plunged from blood vessel into organ due to breakdown of blood-brain barrier in cerebral. Subject and Method : Subject of study was 29 patients whose diagnosis were confirmed by biopsy after surgery and 550 (11 slice$\times$50 image) perfusion MRI were used to make image of relative cerebral blood volume with the program furnished on instrument. The other method was to transmit to private computer and the image analysis was made additionally by making image of relative cerebral blood volume-reformulated singular value decomposition, rCBV-rSVD and permeability using IDL.6.2. In addition, Kruskal-wallis test tonggyein non numerical average by a comparative analysis of brain tumors Results : The rCBV ratio (Functool PF; GE Medical Systems and IDL 6.2 program by analysis) and permeability ratio of tumors were as follows; high grade glioma(n=4), (14.75, 19.25) 13.13. low grade astrocytoma(n=5) (14.80, 15.90) 11.60, glioblastoma(n=5) (10.90, 18.60), 22.00, metastasis(n=6) (11.00, 15.08). 22.33. meningioma(n=6) (18.58, 7.67), 5.58. oliogodendroglioma(n=3) (23.33, 16.33, 15.67. Conclusion : It was not easy to classify the grade with the relative cerebral blood volume ratio measured by using the relative cerebral blood image by type of tumors, however, permeability ratio measured by permeability image revealed that the higher the grade of tumor, the higher the measured permeability ratio, showing the assessment of tumor grade is more effective to differential diagnosis.

  • PDF

Development of the Algorithm for On-line Dosimetry System for High Energy Radiation Treatment (고에너지 방사선치료용 on-line 선량측정시스템을 위한 알고리즘의 개발)

  • Wu, Hong-Hyun;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.207-218
    • /
    • 1997
  • Purpose: The objective of this study is to develop an algorithm for estimation of tumor dose using measured transmission dose as a part of the development of on-line dosimetry system. Materials and Methods: Data of transmission dose were measured under various FS, Tp and PCD with a special water phantom for 6 MV and 10 MV X-ray. SCD (source-chamber distance) was set to 150 cm. Measurements were conducted with a 0.125 cc ion chamber. Results: Using measured data and regression analysis, two algorithms were developed for estimation of expected reading for measured data. Algorithm 1 consisted of the quadratic function of PCD and the tertiary function of AlP (area-perimeter ratio). Algorithm 2 consisted of the tertiary function of log(A/P)and the tertiary function of PCD. Algorithm 2 required less data set and was more accurate in comparing expected and observed dose. Conclusion: Using the algorithm developed, transmission dose can be estimated for any exposure condition, i.e. any given Tp, PCD and FS with high accuracy. To complete this algorithm, further developments are needed regarding the beam modifying device, the tissue inhomogeneity and the irregular body surface.

  • PDF

How does Gamma - Radiation Disappear within a Matter (감마선은 어떻게 소멸하게 되는가\ulcorner)

  • 주승환;제원목
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.1
    • /
    • pp.5-15
    • /
    • 1997
  • 방사선들 중에서 감마선은 우리의 몸 속을 깊숙이 침투할 수 있다. 그런 감마선이 우리 몸을 투과할 때, 체세표를 이룬 원자들의 궤도전자들과 충돌하면서 소멸된다. 우리는 그런 현상들을 물질과의 상호작용 이라 부른다. 방사선과 물질과의 상호작용은 원자의 단위에서 일어난다. 감마선이 물질과의 상호작용들은 물리적으로는 광전자 산란 효과, 컴프턴 산란 효과 그리고 전자쌍 생성효과 등으로 구분하여 설명된다. 방사선이 우리의 몸 속에서 체세포의 원자와 충돌하여 생기는 자유전자들은 몸 속에 남게 되고, 그들은 몸 속을 상당 기간 동안 배회하면서 인체의 생명 현상을 유지시킬 생화학 작용의 기능들을 약화시키기도 하고, 악성인 암세포들을 만들어내기도 하므로 건강 유지에 불리하게 작용한다. 따라서 감마선에 쪼여 생긴 자유전자들은 우리의 정상적인 건강 조건들을 해치는 주된 요소가 된다.

  • PDF

THE FLORID OSSEOUS DYSPLASIA OF THE JAWS (악골에 발생한 Florid Osseous Dysplasia의 방사선학적 연구)

  • Park Tae Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.19-22
    • /
    • 1989
  • Three cases of florid osseous dysplasia of the jaw were investigated. Radiographs showed sclerotic. globular and ground glass opacities throughout the jaws. Two cases were asymptomatic but one case failed to heal following extraction of the mandibular molar and infection complicated the disease. These cases appear to represent the most exuberant manifestations of this reactive benign fibro-osseous lesion of the jaws.