• Title/Summary/Keyword: 방사선 투과도

Search Result 658, Processing Time 0.021 seconds

Study on the Image Quality Comparison between in Digital RT and Film RT (용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구)

  • Park, Sang-Ki;Ahn, Yean-Shik;Gil, Doo-Song
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.391-397
    • /
    • 2011
  • Conventional film radiographic test has been generally and widely used in the inspection on the weldment for quality assurance. On the other hand, since the analog RT is well known for typical time and cost consuming method with complex process of inspection, the industry has researched various ways how to improve radiographic test technology. In this study, we verified the fact that digital RT provides a lot more benefit in effectively detecting defects, ever film details, through digital processing of image enhancement, compared to film RT. As a result, we reached conclusion that digital RT is positively able to replace the film RT in industry in part or in whole.

RADIOPACITY OF CAD/CAM CERAMICS (CAD/CAM용 도재의 방사선 불투과성에 관한 연구)

  • Lee, Jong-Hyeok;Choi, Han-Seuk;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.357-365
    • /
    • 1998
  • 목적: 치과용 수복재료의 방사선 불투과성은 매우 다양하다. 따라서 다양한 수복재료의 방사선 불투과성을 인지하여 치질과 비교하면 이차우식의 진단에 도움이 될 수 있다. 도재의 방사선 불투과성에 따라 적절한 luting cement의 선택이 가농해진다. 수복재료의 방사선 불투과성은 알루미늄 step wedge 의 후경과 방사선 불투과성과의 상관관계 의해 측정된다. 본 연구의 목적은 CAD/CAM용 도재와 이틀의 접착에 쓰이는 접착재료의 방사선 불투과성을 조사해 적절한 재료의 선택과 이차우식 진단의 효율결정에 도움이 되게 하는데 있다. 방법: 본 실험에서는 CAD/CAM용 도재인 Vita MarkII, Dicor MGC와 이의 접착에 사용되는 Z-100, 그리고 luting cement인 Duo cement, Scotchbond resin cement를 사용해 방사선 불투과성을 측정하였다. 시편 제작을 위해 도재를 저속절단기로 두께 2mm, 3mm로 절단하였으며 Z-100과 cement시편은 두께 2mm와 3mm, 직경 7.0mm의 금속 주형을 제작한 후 재료를 양쪽 면에 유리판을 대고 조임쇠로 압접하였으며 광조사기를 사용하여 각 재료마다 두 가지 두께로 10개씩 100개의 시편을 제작하였다. 치질의 시편을 얻기 위해 교정 목적으로 최근에 발거된 정상적인 상악 소구치를 저속 절단기를 사용하여 협설측 교두정을 기준 삼아 2mm, 3mm 두께로 절단하였으며 방사선 불투과성의 기준을 위해 12개의 step으로 구성된 12mm두께의 aluminum step wedge를 사용하였다. Kodak E-Speed occlusal film에 aluminum step wedge와 시편들을 위치시킨 후 70kVp, 7mA, 2.16mm aluminum filtration으로 고정된 dental X-ray unit을 사용하여 target과 film 사이의 거리는 25cm, 노출시간은 0.2초로 하여 방사선 촬영을 한 다음, 현상된 방사선 사진상에 나타난 방사선 불투과성을 X-rite 301 densitometer를 이용하여 측정한 값들의 평균을 냈다. 얻어진 결과는 one-way ANOVA Duncan test(P<0.01)로 검증하였다. 결론: 1. Dicor MGC의 방사선 불투과성은 법랑질보다 약간 높게 나타났다.(P<0.01) 2. Vita Mark Il는 상아질보다 낮은 방사선 불투과성을 보였다.(P<0.01) 3. Z-100과 Luting cement들의 방사선 불투과성은 법랑질보다 높았다. Duo cement가 방사선 불투과성이 가장 높았고 그 다음이 Z-100, 그리고 Scotchbond resin cement 순이었다. 4. Z-100과 2종류의 방사선 불투과성 luting cement들은 Vita Mark II 와 같이 사용하면 2차우식 진단에 도움이 된다.

  • PDF

A STUDY ON THE RADIOPACITY OF ESTHETIC DENTAL MATERIALS USING IN THE PEDIATRIC DENTISTRY (소아용 심미수복재의 방사선 불투과성에 관한 연구)

  • Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.82-86
    • /
    • 2001
  • The aim of this study was to investigate the level of radiopacity of esthetic dental restorative materials and determine the optimum level of radiopacity in pediatric dentistry. Disks of 8 dental restorative material groups as the experimental group, 7mm in diameter and 2mm thick, were radiographed with intact human deciduous teeth and aluminum stepwedge standard. Radiopacity was evaluated with an image analysis program following the digitization of the radiographs using a flatbed scanner with transparency unit. All materials and tooth structure also the significant difference except FP, VB, VM. For the radiopacity of esthetic restorative dental materials to exceed that of enamel, it should be greater than 1.7mm of equivalent thickness of aluminum.

  • PDF

임상가를 위한 특집 2 - 구강악안면영역에서 양성 종양의 영상진단

  • Kim, Gyeong-A
    • The Journal of the Korean dental association
    • /
    • v.47 no.10
    • /
    • pp.637-646
    • /
    • 2009
  • 양성 종양(benign tumor)을 언급하기에 앞서 과오종(hamartoma) 및 과다 형성(hyperplasia)과의 차이를 구분할 필요가 있다. 양성 종양은 기원조직과 유사한 조직이 이상 증식하는 것으로 서서히 성장하지만 일반적으로 치료하기 전까지 이상 증식을 지속하는 진성 신생물을 일컫는다. 이에 비해 과오종은 정상 조직이 무질서하게 과증식하는 것으로 일정기간 후에는 성장을 멈추기 때문에 진성 신생물로 간주하지 않는다. 그러나 일부 과오종이 양성 종양에 포함되기도 하는데, 예를 들어 치아종은 정상적인 치성 조직의 성장이 완료되는 시기와 거의 동일한 시기에 성장을 멈추지만 양성 종양으로 분류된다. 과다 형성은 조직의 세포가 정상적인 배열 양상을 보이면서 세포의 수가 증가하는 것으로 지속적인 성장 양상을 보이지만 그 성장이 제한적이므로 양성 종양과는 구별된다. 양성 종양은 일반적으로 무통성으로 서서히 성장하기 때문에 종양의 크기가 증가하여 안면 종창이나 동통 등을 유발하는 경우에 발견될 수 있으며, 방사선검사에서 우연히 발견되기도 한다. 방사선검사는 병소의 위치, 범위, 특징 및 병소와 인접 해부학적 구조와의 관계 등 많은 방사선학적 진단 정보를 제공한다. 일부 종양은 방사선사진에서 매우 특징적인 소견을 나타내기 때문에 방사선학적 소견으로 예비 진단을 할 수 있을 정도의 진단정보를 제공하기도 하는 반면 어떤 종양들은 방사선사진에서 관찰되는 소견이 매우 유사하여 진단에 어려움을 주기도 한다. 따라서 종양의 확진을 위해서는 생검이 필수적이며, 방사선검사는 반드시 생검에 앞서 진행되어야만 정확한 방사선학적 진단을 할 수 있다. 양성 종양은 각각의 특징적인 방사선학적인 소견을 나타내지만 일반적으로 관찰되는 양성 종양의 특징이 존재하므로 이러한 일반적인 특징을 관찰하여 병소가 양성인지 악성인지를 감별할 수 있다. 첫째, 양성 종양은 대개 호발하는 부위가 있으므로 종양의 발생부위는 감별 진단을 하는 데 매우 중요하다. 일반적으로 치성 병소는 치아가 형성되는 하악관 상방의 치조돌기에서, 혈관성 및 신경성 병소는 하악관 내에서, 연골성 종양은 하악과두와 같이 연골세포가 잔존되어 있는 부위에서 발생하는 경우가 많다. 둘째, 양성 종양은 대체로 명확한 경계와 피질골성 변연을 보이며, 종종 병소가 결체조직으로 둘러싸여 있어 병소 주위에 방사선투과성 띠가 관찰되기도 한다. 셋째, 양성 종양은 일반적으로 인접 주위 조직에 압력을 가하면서 서서히 성장하기 때문에 인접 치아의 변위 또는 흡수, 피질골의 비박, 팽융 등의 소견을 보이며 피질골의 천공은 드물다. 방사선학적으로 양성 종양의 병소 내부는 방사선투과상으로 관찰되거나, 방사선불투과상으로 관찰되거나, 방사선투과상과 방사선불투과상이 혼재된 상으로 관찰된다. 저자는 이 지면에서 이러한 방사선학적 특징을 기초로 하여 구강악안면영역에 발생하는 양성 종양을 분류하고 각각의 특징에 대해 살펴보고자 한다.

  • PDF

방사선투과사진에 의한 결함깊이 및 높이의 평가

  • 심언덕;이진우;이수경;강계명
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.249-256
    • /
    • 2002
  • 구조물의 안전성 평가와 수명예측은 구조물 내 결함에 관한 정확한 정보 즉, 결함의 종류, 크기, 위치, 형상으로 평가하고 있다 이들 결함의 분석과 해석 방법으로 실시간 평가가 가능하고, 구조물에 손상을 주지 않는 비파괴 결함 평가 방법이 널리 활용되고 있다. 특히 방사선투과시험에 의한 결함 해석과 평가는 투과사진 상에 나타나는 결함의 상으로부터 결함 형상과 결함 길이는 직접 확인할 수 있으며, 결함 깊이와 결함 높이의 해석에는 입체방사선투과검사법(Stereo-radiography)과 parallax법 등으로 현재 결함 깊이와 높이를 해석하고 있으나, 이러한 방법은 결함 검출을 위하여 조사방향을 여러방향으로 하여 방사선 투과사진을 다수 촬영하여야 하고, 촬영된 결함의 분석과 해석에도 숙련된 평가 기법이 요구되는 등 많은 문제점을 내포하고 있다.(중략)

  • PDF

Separation Permeation Characteristics of N2-O2 Gas in Air at Cell Membrane Model of Skin which Irradiated by High Energy Electron (고에너지 전자선을 조사한 피부의 세포막모델에서 공기 중의 O2-N2 혼합기체의 분리투과 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.261-270
    • /
    • 2019
  • The separation permeation characteristics of $N_2-O_2$ gas in air at cell membrane model of skin which irradiated by high energy electron(linac 6 MeV) were investigated. The cell membrane model of skin used in this experiment was a sulfonated polydimethyl siloxane(PDMS) non-porous membrane. The pressure range of $N_2$ and $O_2$ gas were appeared from $1kg_f/cm^2$ to $6kg_f/cm^2$. In this experiment(temperature $36.5^{\circ}C$), the permeation change of $N_2$ and $O_2$ gas in non-porous membrane by non-irradiation were found to be $1.19{\times}10^{-4}-2.43{\times}10^{-4}$, $1.72{\times}10^{-4}-2.6{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. That of $N_2$ and $O_2$ gas in non-porous membrane by irradiation were found to be $0.19{\times}10^{-4}-0.56{\times}10^{-4}$, $0.41{\times}10^{-4}-0.76{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. The irradiated membrane was significantly decreased about 4-10 times than membrane which was not irradiated. And ideal separation factor of $N_2$ and $O_2$ gas by non-irradiation was found to be from 1.32 to 0.42 and that of $N_2$ and $O_2$ gas by irradiation was found to be from 0.237 to 0.125. The irradiated membrane was significantly decreased about 4-5 times than membrane which was not irradiated. When the operation change(cut) and pressure ratio(Pr) by non-irradiation were about 0, One was increased to the oxygen enrichment and the other was decreased to the oxygen enrichment. The irradiated membrane was significantly decreased about 4-19 times than membrane which was not irradiated. As the pressure of $N_2$ and $O_2$ gas was increased, the selectivity was decreased. As separation permeation characteristics of $N_2-O_2$ gas in cell membrane model of skin were abnormal, cell damages were appeared at cell.

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.

Interpretation for Band-Type Indication on Radiography of 9% Ni Steel Welds for LNG Storage Tanks (액화천연가스 저장탱크 9% 니켈강 용접부의 방사선투과시험 필름에 나타나는 밴드형상의 지시 해석)

  • Lee, Seung-Hyun;Lee, Seung-Rim;Lee, Young-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.479-483
    • /
    • 2010
  • 9% nickel alloy steels used for LNG, cryogenic liquid, storage tank are welded with dissimilar Inconel or Hastelloy welding rod and the weldment shows similar characteristic with the dissimilar metal weld of low carbon steel and austenitic stainless steel. Band type indications are sometimes shown on the film during radiography test of the weldments. Thus this study identified whether the indications are non-relevant indications through material, radiographic test, ultrasonic test, liquid penetrant test and microstructure analysis and also proposed radiography film interpretation and cause of band type indications.

Broad Beam Transmission Properties of some Shielding Materials for Use in Diagnostic Radiology (진단영역 넓은 선속 X선 에너지에 대한 차폐물질의 투과 특성)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Lin, Song-Shei
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.23-29
    • /
    • 2004
  • The application of analytical model(Archer et al. 1983) to shielding calculations in diagnostic radiology combined with measurements of the broad beam transmission properties of lead, steel, concrete, and plate glass for x-ray tube potential of 60-140 kVp using an x-ray inverter generator and total initial beam filtration sufficient to provide half-valve layer representative of those found in common practice and required by regulatory agencies. Our transmission measurements and numerical fits to the mathematical model of broad beam transmission(Archer et al. 1983) will assist medical or health physicist faced with the task of designing protective barriers for medical diagnostic x-ray facilities.

  • PDF

Automated Ultrasonic Testing of Offshore Structure (플랜트 해양구조물의 자동 초음파탐상검사)

  • Jyung, D.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.1
    • /
    • pp.42-45
    • /
    • 1998
  • 원유 또는 가스 생산을 위해 해상에 설치되는 플랜트 해양설비는 크게 jacket과 module로 나눌 수 있다. Jacket은 module을 지지하기 위한 구조물로써 jacket 본체와 pile로 구성되어 있으며, 미국용접학회(AWS)의 규정에 의해 대부분의 맞대기 완전용접 이음부(full penetration butt welds)에 대해 100% 방사선투과검사를 실시하게 되어 있다. 그러나 지금까지 방사선투과검사를 실시해 온 경험으로 미루어 볼 때 방사성에 대한 안전성, 생산공정의 영향(검사지연) 등 방사선투과검사는 많은 문제점을 가지고 있었다. 이에 대한 문제점을 해소하고, 국내의 비파괴검사 기술 향상을 위해 자동 초음파탐상 system을 개발, 방사선투과검사를 자동 초음파탐상검사로 대체하여 적용한 사례를 간략하게 기술하였다. 또한, 적용 확대를 위해 개방중인 system을 소개하고 아울러 자동 초음파탐상기술에 대한 앞으로의 방향을 제시하였다.

  • PDF