• Title/Summary/Keyword: 방사선 촬영

Search Result 2,076, Processing Time 0.024 seconds

Patient exposure doses from medical x-ray examinations in Korea (진단방사선검사에서 환자피폭선량에 관한 연구)

  • Kim, You-Hyun;Choi, Jong-Hak;Kim, Sung-Soo;Oh, Yuw-Han;Lee, Chan-Hyeup;Cho, Pyong-Kon;Kang, Dae-Hyun;Lee, Young-Bae;Kim, Hyung-Chul;Kim, Chel-Min
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2005
  • X-ray examinations represent the largest man-made source of radiation exposure for the population. The need for standardization of radiation exposures has been suggested and the guidance levels for various radiographic and radioisotope examinations has been proposed by the International Atomic Energy Aency(IAEA) as a safety standard. In many countries, the situation of medical radiographic exposures in each country should be researched before the appropriate guidance level is established. In this study, measurements of entrance surface dose, dose-area product(DAP), computed tomograghic dose index(CTDI) and mean glandular dose(MGD) were carried out in patients who underwent routine x-ray examinations, fluoroscopy, computed tomograghy and mamography in Korea. These measured quantities were compared with the results from the calculation method in previous study. And we suggested diagnostic reference levels in medical imaging in Korea.

  • PDF

A Study on the Chest Indirect Radiography (흉부X선 간접촬영의 촬영조건과 화질에 관한 조사연구)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2003
  • chest Indirect radiography were taken at 44 medical facilities in Seoul area. The results were as follows: 1. The average tube voltage was 98.2 kVp in case of 100 mm film and 91.3 kVp in case of 70 mm film. 2. The average tube current was 18.1 mAs in case of 100 mm film and 42.5 mAs in case of 70 mm film. 3. In the physical evaluation of chest Indirect radiographs, the density in case of 100 mm film was similar to that in case of 70 mm film. 4. In the visual evaluation of chest Indirect radiographs, the score of identification in case of 100 mm film was higher than that in case of 70 mm film. 5. The average dose of radiation into the skin was 1.38 mGy in case of 100mm film and 4.59 mGy in case of 70 mm film. In conclusion, the image quality of chests was excellent and the dose of radiation into the skin decreased in case of 100 mm film.

  • PDF

Optimization of Exposure Parameters in Brain Computed Tomography (두부 전산화단층촬영에서 노출 파라미터의 최적화)

  • Ko, Seong-Jin;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.355-362
    • /
    • 2010
  • This study determines a range of CT parameter values in Brain CT which are minimizing patient absorption dose without compromising the image quality and optimal exposure condition. We measured dose and image noise using conventional CT parameters in Brain CT. In additon, we evaluated dose, SNR and PSNR of head phantom images while changing kVp and rotation time. In this study, effectiveness of dose that was achieved from dose reproducible experiments in conventional head CT condition is determined by changing kVp and rotation time. Dose and PSNR is related to low dose-high resolution condition. In conclusion, we suggest that using proposed conditions is effective for imaging to compare with conditions proposed by the manufacturer.

A Study on Projection for Apophyseal Joints Diagnosis in X-ray Thoracic Bone Oblique Projection (X-ray 등뼈의 사위 촬영에서 돌기사이관절의 진단을 위한 촬영법 연구)

  • Jun-Heang Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.351-357
    • /
    • 2023
  • This Study Rreceived Subjective Evaluation ROC Evaluation from five projection. of projection. at a University Hospital to Obtain and Diagnose Sharp images of apophyseal joints and Vertral arch of Thoracic vertebrae from thoracic X-ray projection. In the Subjective evaluation, the highest Score was obtained by raising the phantom from Supine to LAO by 70° and scoring 20 points at 5° with the X-ray Tube facing the head. In addition, he scored the highest score of 19 points at 8° with the Prone Phantom standing 60° with RAO and the X-ray Tube facing the head. For Objective Evaluation, the Signal-to-noise ratio, was calculated. ROI was set at 1,564 mm2 to obtain the image signal average value (Mean value) and the Standard deviation (SD value). Objective Evaluation The signal-to-noise ratio, was the highest at 5° toward the head in the LPO 70° position of the phantom in the lying position of the Thoracic spine projection, and the Thoracic Spine was the highest at 8° toward the head of the RAO posture of 5,645.

X-ray Arcelin Projection Study for Diagnosing Mastoid Process and Petrous Ports (꼭지돌기와 바위부 진단을 위한 엑스선 Arcelin 촬영법 연구)

  • Jun-Haeng Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.301-307
    • /
    • 2024
  • The Study Evaluated Radiography Images using the Mastoid Process Axial Oblique Projection (Arcelin) imaging method for the Diagnosis of Pyramid Ridge, Mastoid Process, Mastoid Process air cells, Tympanum, Internal auditory and petrous in Supine Position. The subjective ROC (receiver operation characteristic) evaluation method was conducted on five Radiological technologists who have worked in the Image medical Department of University Hospitals for more than 8 years, and the Objective Evaluation, signal-to-noise Ratio (SNR), was evaluated and Analyzed. The Cronbach Alpha value was significantly higher at 0.816. In the Image ROC Evaluation Taken by Tilting the X-ray Tube 5°, 10°, 15° toward the leg by 10°, it Scored 34 points, and in the overall evaluation, the SNR scored high at 6,549. In Addition, In the Image Evaluation taken by Tilting the X-ray Tube 5°, 10°, and 15° toward the head, it Scored 32 points In the Image ROC Evaluation taken by tilting 5°, and in the Objective Evaluation, SNR received the highest score of 6,732.

Facial Exposure Dose Assessment During Intraoral Radiography by Radiological Technologists (구내 촬영시 방사선사의 안면부 피폭선량 측정)

  • Yu, Hwan;Yang, Hanjoon
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.195-201
    • /
    • 2014
  • The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60kVp, 10mA, 50msec) and for children (60kVp, 10mA, 20msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, and 40cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10cm under the adult conditions. The rate at the distance of 40cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

A Study on Radiation Beam Quality Set-up of Mammography Equipment and Average Glandular Dose (유방 촬영 장치의 국제 규격 Beam Quality 기준에 따른 평균 선량 평가에 관한 연구)

  • Park, Yoon-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Mammography using X-rays is currently the most used for early diagnosis of breast cancer. As the frequency of use of X-ray devices increases, interest in radiation hazards caused by mammography is increasing. Therefore, in this study, in order to measure the exposure dose of the mammary gland in X-ray mammography that requires high contrast and high resolution, the international Atomic Energy Agency (IAEA) stipulates the international standards presented by IEC 62220-1-2: 2015. Based on the beam quality criteria of the recommendation, we tried to present a guideline for evaluating the average mammary gland dose. As a result, the average streamline dose value of the 4.5 cm PMMA phantom was 2.3 mGy at the maximum within the 30 kV range, and was evaluated to be 1.19 mGy based on 28 kV.