Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Radioactivation Analysis of Concrete Shielding Wall of Cyclotron Room Using Monte Carlo Simulation (PET 사이클로트론 가동에 따른 콘크리트 차폐벽의 방사화)

  • Jang, Donggun;Lee, Dongyeon;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.335-341
    • /
    • 2017
  • Cyclotron is a device that accelerates positrons or neutrons, and is used as a facility for making radioactive drugs having short half-lives. Such radioactive drugs are used for positron emission tomography (PET), which is a medical apparatus. In order to make radioactive drugs from a cyclotron, a nuclear reaction must occur between accelerated positrons and a target. After the reaction, unncessary neutrons are produced. In the present study, radioactivation generated from the collisions between the concrete shielding wall and the positrons and neutrons produced from the cyclotron is investigated. We tracked radioactivated radioactive isotopes by conducting experiments using FLUKA, a type of Monte Carlo simulation. The properties of the concrete shielding wall were comparatively analyzed using materials containing impurities at ppm level and materials that do not contain impurities. The generated radioactivated nuclear species were comparatively analyzed based on the exposure dose affecting human body as a criterion, through RESRAD-Build. The results of experiments showed that the material containing impurities produced a total of 14 radioactive isotopes, and $^{60}Co$(72.50%), $^{134}Cs$(16.75%), $^{54}Mn$(5.60%), $^{152}Eu$(4.08%), $^{154}Eu$(1.07%) accounted for 99.9% of the total dose according to the analysis having the exposure dose affecting human body as criterion. The $^{60}Co$ nuclear species showed the greatest risk of radiation exposure. The material that did not contain impurities produced a total of five nuclear species. Among the five nuclear species, 54Mn accounted for 99.9% of the exposure dose. There is a possibility that Cobalt can be generated by inducive nuclear reaction of positrons through the radioactivation process of $^{56}Fe$ instead of impurities. However, there was no radioactivation because only few positrons reached the concrete wall. The results of comparative analysis on exposure dose with respect to the presence of impurities indicated that the presence of impurities caused approximately 98% higher exposure dose. From this result, the main cause of radioactivation was identified as the small ppm-level amount of impurities.

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging (텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가)

  • Min, Jung-Whan;Son, Jin-Hyun;Kim, Ki-Won;Lee, Jung-Woo;Son, Soon-Yong;Back, Geum-Mun;Kim, Jung-Min;Kim, Yeon-Rae;Jung, Jae-Yong;Kim, Sang-Young;Lee, Do-Wan;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.154-161
    • /
    • 2012
  • Digital Radiography (DR) has rapidly developed in megavoltage X-ray imaging (MVI). Thus, a very simple and general quality assurance (QA) method is required. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) for MVI using general QA method and computed radiography (CR) device. We used tungsten edge block with $19{\times}10{\times}1cm^3$ thickness and 6MV energy. For detector, CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen) were used and pre-sampling MTF was calculated. The MTF of CR-IP-front showed the highest value with 1.10 lp/mm although the CR-IP showed the only 0.70 lp/mm. The best NPS was observed in CR-IP front screen. According to the increase in spatial frequency, our results showed that DQE was approximately 1.0 cycles/mm. The present study demonstrates that the QA method with our home-made edge block can be used to evaluate MTF, NPS and DQE for MVI.

Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom (자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가)

  • Lee, Ji-Eun;Kim, Jae-Won;Kang, Dong-Yoon;Choi, Jae-Hyeok;Yeom, Du-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.115-121
    • /
    • 2012
  • Purpose: The process of the proton treatment is done by comparing the DRR and DIPS anatomic structure to find the correction factor and use the PPS to use this factor in the treatment. For the accuracy of the patient set up, the PPS uses a 6 axis system to move. Therefore, there needs to be an evaluation for the accuracy between the PPS moving materialization and DIPS correction factor. In order to do this, we will use a self made PPS QA Phantom to measure the accuracy of the PPS. Materials and Methods: We set up a PPS QA Phantom at the center to which a lead marker is attached, which will act instead of the patient anatomic structure. We will use random values to create the 6 axis motions and move the PPS QA Phantom. Then we attain a DIPS image and compare with the DRR image in order to evaluate the accuracy of the correction factor. Results: The average correction factor, after moving the PPS QA Phantom's X, Y, Z axis coordinates together from 1~5 cm, 1 cm at a time, and coming back to the center, are 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$ on the PPS 6 axis. The average correction rate when moving the 6way movement coordinates all from 1 to 2 were 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$ when moved 1 and 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$ when moved 2. Conclusion: After evaluating the correction rates when they come back to the center, we could tell that the Lateral, Longitudinal, Vertical were all in the acceptable scope of 0.5 cm and Rotation, Pitch, Roll were all in the acceptable scope of $1^{\circ}$. Still, for a more accurate proton therapy treatment, we must try to further enhance the image of the DIPS matching system, and exercise regular QA on the equipment to reduce the current rate of mechanical errors.

  • PDF

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF