• 제목/요약/키워드: 방사선 이용통계

Search Result 572, Processing Time 0.029 seconds

Neutron dosimetry depending on the number of portals for prostate cancer IMRT(Intensity-Modulated Radiation Therapy) (전립선암의 세기조절 방사선치료 시 조사문수별 중성자선량 평가)

  • Lee, Joo-Ah;Son, Soon-Yong;Min, Jung-Whan;Choi, Kwan-Woo;Na, Sa-Ra;Jeong, Hoi-Woun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3734-3740
    • /
    • 2014
  • The aim of this study was provide basic information and establish the criteria in radiation therapy planning by measuring the absorbed neutron dose of normal tissues and lesions according to the number of portals. From September 2013 to January 2014, 20 patients who were diagnosed with prostate cancer and were previously treated with radiation therapy were replanned retrospectively to measure the absorbed neutron dose distribution according to the number of portals. The absorbed neutron dose was measured in each of the 5, 7 and 9 portals using a 15 MV energy, which meant a therapeutic dose of 220 cGy. The optical stimulation luminescence dosimeter was separated by 20cm and 60cm away from the center of the field of view. As a result, the average radiation dose in the abdomen appeared to have a positive relationship with the number of portals, which was statistically significant (p<.05). The average radiation dose was $4.34{\pm}1.08$. The average radiation dose in the thyroid was $2.71{\pm}.37$. Although it showed a positive relationship with the number of portals, it did not have statistical significance. The number of portals and the neutron dose depending on the position showed a significant positive relationship, particularly in the abdomen. As a result of linear regression analysis, as the number of the portal increased in steps, the average volume of the neutrons increased significantly (0.416 times). In conclusion, efficient selection of the number of portals is needed considering the difference in the absorbed neutron dose in the normal tissues depending on the number of the portals.

The Relationship between Coronary Risk Factors and Coronary Calcium Score Detected by Computed Tomography Coronary Angiography in Korean Middle Aged Men (다중절편 방사선단층촬영 결과에 기반한 한국 중년 남성에서의 관상동맥 석회화와 심혈관질환 위험인자와의 연관성)

  • Park, Seung-Hyun;Kim, Young-Wook;Chae, Chang-Ho;Kim, Ja-Hyun;Kang, Yune-Sik;Park, Yong Whi;Jeong, Baek Geun
    • Journal of agricultural medicine and community health
    • /
    • v.39 no.1
    • /
    • pp.25-36
    • /
    • 2014
  • Objectives: The objective of this study was to investigate the relationship between coronary artery calcification and risk factors of cardiovascular disease with multidetector computed tomography. Methods: Data were collected from 5,899 males between 30 and 59 years old by interview, survey, physical examination, blood test, and multidetector computed tomography in the university hospital from January 2010 to December 2011. We confirmed the coronary artery calcium scores of subjects by multidetector computed tomography and identified risk factors of cardiovascular disorders. We investigated the relationship between coronary artery calcification and risk factors of cardiovascular disorders. Results: Mean calcium score of the coronary arteries in 5,899 participants was 8.20, and 773 participants (13.1%) exhibited coronary artery calcification. The presence of coronary artery calcification was correlated to risk factors of cardiovascular disease (age, blood pressure, triglyceride, HDL cholesterol, LDL cholesterol, glucose, Apolipoprotein A-1, Apolipoprotein B, body mass index, waist circumference) and risk assessment tools of cardiovascular disorders. Significant predicted factors of coronary artery calcification had different patterns in each age group (30-39, 40-49, 50-59 years old). Conclusions: We confirmed the relationship between coronary artery calcification and either typical risk factors of cardiovascular disease or risk assessment tools of cardiovascular disease. In addition, we also observed that the pattern of these factors varied according to age. Therefore, age-related variation needs to be considered in management strategies to prevent cardiovascular disease.

Limited Lateral Retinacular Release for Treatment of Painful Bipartite Patella (통증이 있는 이분슬개골의 제한적인 외측 지대 유리술 치료)

  • Yi Seung Rim;Hahn Sung Ho;Yang Bo Kyu;Chung Shun Wook;Ha Jung Hyun;Ahn Young Joon;Chung Byung June;Jeon Do Hwan;Bin Sung Woo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.60-65
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the results of limited vastus lateralis release for treatment of painful bipartite patella. Materials and Methods: From Jan. 1995 to Jun. 2002, we performed limited lateral retinacular release in 14 patients(16 cases) for treatment of painful bipartite patella. All patients were men and mean age was 22.3 years old. The opeative techique was that insertion of the vastus lateralis to the painful patellar fragment is detached subperiosteally. We evaluated the clinical results by degree of pain and level of activity. Also we analyzed the radiologic findings by measuring fragment tilting angle and gap between fragments. The mean follow up period was 14 months. Results: At final follow up, all of the patients showed pain relief and can be returned to more than recreational sports activity after the operation. On radiologic findings, fragment tilting angle and gap between fragments were reduced at statistically significant level. Conclusion: The limited lateral retinacular release for treatment of painful bipartite patella is one of good methods which is less invasive and shows good results in clinical and radiologic findings.

  • PDF

Effects of The Sub ROI Changes on Exposure Index (Sub ROI 변화가 노출지수에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1149-1155
    • /
    • 2023
  • This study aims to investigate the effect of changes in the Sub ROI on exposure index(EI) and to present indicators of changes in EI values that may occur when changing Sub ROI in clinical practice. This study was conducted on a subject of 20 cm of acrylic for a setting similar to abdominal radiography, and the specifications of one acrylic sheet is 20 × 20 × 5 cm. The survey conditions were the same as 80 kVp , 320 mA, 25 ms, SID 110 cm and the Sub ROI obtained 30 images for each type using five types provided by the equipment company. The EI value provided by the equipment and entrance skin exposure(ESE) were compared and analyzed. The mean value of EI according to the change in Sub ROI was 101.18±0.27 for LS, 106.57±0.31 for AEC, 107.74±0.39 for VR, 107.90±0.38 for HR, and 109.72±0.32 for SS (p<0.01). The average value of ESE by sub ROI type (LS, AEC, VR, HR, SS) was measured to be 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, and 477.14±1.46 μGy, with statistically significant differences (p<0.01). As a result of this study, the EI according to the sub ROI type is based on LS(109.72), which represents the minimum value. AEC increased 5.3%, VR increased 6.4%, HR increased 6.6%, SS increased 8.4%, and overall, increased by about 5.3%. As for the average value of ESE, HR(475.61 μGy)type showed the minimum value, and based on this, AEC increased 0.27%, VR increased 0.11%, LS increased 0.17%, SS increased 0.32%, and overall, increased by about 0.17%.

High Energy Resolution Alpha Spectrometer Using a Cryogenic Detector (저온검출기를 이용한 에너지 고 분해능 알파분광 구현)

  • Kim, M.S.;Lee, S.H.;Yoon, W.S.;Jang, Y.S.;Lee, S.J.;Kim, Y.H.;Lee, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.132-137
    • /
    • 2013
  • Cryogenic particle detectors have recently been adopted in radiation detection and measurement because of their high energy resolution. Many of these detectors have demonstrated energy resolutions better than the theoretical limit of semiconductor detectors. We report the development of alpha spectrometer using a micro-fabricated magnetic calorimeter coupled to a large-area particle absorber. A piece of gold foil of $2{\times}2{\times}0.05mm^3$ was glued to the paramagnetic temperature sensor made of sputtered Au:Er film to serve as an absorber for incident alpha particles. We performed experiments with 241Am source at cryogen free adiabatic demagnetization refrigerator (CF-ADR). A high energy resolution of 6.8 keV in FWHM was obtained for 5.5 MeV alpha particles.

The Influence of gender or culture on determining esthetic facial profile (심미적 측모 판단에 미치는 성별과 문화의 영향력)

  • Ko, Su-Jin;Kim, Hyun-Soon;Kim, Young-Jin
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.301-309
    • /
    • 2001
  • Because many of patients seeking orthodontic treatment worry about the facial appearance and their chief motivation for orthodontic treatment is facial esthetics, it is critical to understand the influence of gender or culture on the evaluation of profile esthetics. The purpose of this study was to find out any influence of gender or culture on judging good facial profile. 4 different groups were asked to evaluate 133 facial profiles to test the influence of gender or culture on judging good facial profiles. Those 4 groups consisted of 10 Korean males, 10 Korean females, 10 Korean American males, and 10 Korean American females. 2 evaluation systems were introduced, absolute and relative. Soft tissues of selected good profile group were analyzed and statistic analysis was performed. Conclusions were as follows 1. Inter-evaluator difference for judging good facial profile was statistically significant, even if there was general agreement for the best profile among 40 raters. 2. Gender difference under the same cultural environment was not significant statistically. 3. The same ethnic groups with different cultural background showed statistically different preference on judging good Profile. 4. Good facial profile group had their own characteristics compared to remaining group in several soft tissue measurements which were vertical facial ratio, soft tissue facial convexity, and antero-posterior relative lip position.

  • PDF

Comparative Validation of the Mixed and Permanent Dentition at Web-Based Artificial Intelligence Cephalometric Analysis (혼합치열과 영구치열 환자를 대상으로 한 웹 기반 인공지능 두부 계측 분석에서의 비교 검증)

  • Shin, Sunhahn;Kim, Donghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.85-94
    • /
    • 2022
  • This retrospective study aimed to evaluate the difference in measurement between conventional orthodontic analysis and artificial intelligence orthodontic analysis in pediatric and adolescent patients aged 7 - 15 with the mixed and permanent dentition. A total of 60 pediatric and adolescent patients (30 mixed dentition, 30 permanent dentition) who underwent lateral cephalometric radiograph for orthodontic diagnosis were randomly selected. Seventeen cephalometric landmarks were identified, and 22 measurements were calculated by 1 examiner, using both conventional analysis method and deep learning-based analysis method. Errors due to repeated measurements were assessed by Pearson's correlation coefficient. For the mixed dentition group and the permanent dentition group, respectively, a paired t-test was used to evaluate the difference between the 2 methods. The difference between the 2 methods for 8 measurements were statistically significant in mixed dentition group: APDI, SNA, SNB, Mandibular plane angle, LAFH (p < 0.001), Facial ratio (p = 0.001), U1 to SN (p = 0.012), and U1 to A-Pg (p = 0.021). In the permanent dentition group, 4 measurements showed a statistically significant difference between the 2 methods: ODI (p = 0.020), Wits appraisal (p = 0.025), Facial ratio (p = 0.026), and U1 to A-Pg (p = 0.001). Compared with the time-consuming conventional orthodontic analysis, the deep learning-based cephalometric system can be clinically acceptable in terms of reliability and validity. However, it is essential to understand the limitations of the deep learning-based programs for orthodontic analysis of pediatric and adolescent patients and use these programs with the proper assessment.

Evaluation of the Usefulness of Restricted Respiratory Period at the Time of Radiotherapy for Non-Small Cell Lung Cancer Patient (비소세포성 폐암 환자의 방사선 치료 시 제한 호흡 주기의 유용성 평가)

  • Park, So-Yeon;Ahn, Jong-Ho;Suh, Jung-Min;Kim, Yung-Il;Kim, Jin-Man;Choi, Byung-Ki;Pyo, Hong-Ryul;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2012
  • Purpose: It is essential to minimize the movement of tumor due to respiratory movement at the time of respiration controlled radiotherapy of non-small cell lung cancer patient. Accordingly, this Study aims to evaluate the usefulness of restricted respiratory period by comparing and analyzing the treatment plans that apply free and restricted respiration period respectively. Materials and Methods: After having conducted training on 9 non-small cell lung cancer patients (tumor n=10) from April to December 2011 by using 'signal monitored-breathing (guided- breathing)' method for the 'free respiratory period' measured on the basis of the regular respiratory period of the patents and 'restricted respiratory period' that was intentionally reduced, total of 10 CT images for each of the respiration phases were acquired by carrying out 4D CT for treatment planning purpose by using RPM and 4-dimensional computed tomography simulator. Visual gross tumor volume (GTV) and internal target volume (ITV) that each of the observer 1 and observer 2 has set were measured and compared on the CT image of each respiratory interval. Moreover, the amplitude of movement of tumor was measured by measuring the center of mass (COM) at the phase of 0% which is the end-inspiration (EI) and at the phase of 50% which is the end-exhalation (EE). In addition, both observers established treatment plan that applied the 2 respiratory periods, and mean dose to normal lung (MDTNL) was compared and analyzed through dose-volume histogram (DVH). Moreover, normal tissue complication probability (NTCP) of the normal lung volume was compared by using dose-volume histogram analysis program (DVH analyzer v.1) and statistical analysis was performed in order to carry out quantitative evaluation of the measured data. Results: As the result of the analysis of the treatment plan that applied the 'restricted respiratory period' of the observer 1 and observer 2, there was reduction rate of 38.75% in the 3-dimensional direction movement of the tumor in comparison to the 'free respiratory period' in the case of the observer 1, while there reduction rate was 41.10% in the case of the observer 2. The results of measurement and comparison of the volumes, GTV and ITV, there was reduction rate of $14.96{\pm}9.44%$ for observer 1 and $19.86{\pm}10.62%$ for observer 2 in the case of GTV, while there was reduction rate of $8.91{\pm}5.91%$ for observer 1 and $15.52{\pm}9.01%$ for observer 2 in the case of ITV. The results of analysis and comparison of MDTNL and NTCP illustrated the reduction rate of MDTNL $3.98{\pm}5.62%$ for observer 1 and $7.62{\pm}10.29%$ for observer 2 in the case of MDTNL, while there was reduction rate of $21.70{\pm}28.27%$ for observer 1 and $37.83{\pm}49.93%$ for observer 2 in the case of NTCP. In addition, the results of analysis of correlation between the resultant values of the 2 observers, while there was significant difference between the observers for the 'free respiratory period', there was no significantly different reduction rates between the observers for 'restricted respiratory period. Conclusion: It was possible to verify the usefulness and appropriateness of 'restricted respiratory period' at the time of respiration controlled radiotherapy on non-small cell lung cancer patient as the treatment plan that applied 'restricted respiratory period' illustrated relative reduction in the evaluation factors in comparison to the 'free respiratory period.

  • PDF

Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan (CT 외래환자의 만족도 향상을 위한 업무개선 연구)

  • Han, Man-Seok;Lee, Seung-Youl;Lee, Myeong-Goo;Jeon, Min-Cheol;Cho, Jae-Hwan;Kim, Tae-Hyung
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • Nowadays, most of the hospital serves "one stop service" for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the wating time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

Spectrophotometric Analysis of Crown Discoloration Induced by Various MTA Based Materials (분광분석법을 이용한 수종 MTA의 치관변색 평가)

  • Lim, Yuran;Choi, Namki;Kim, Jaehwan;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.28-37
    • /
    • 2017
  • Mineral trioxide aggregate have been used for many years as a pulp therapy material. The most widely used product, Proroot white $MTA^{(R)}$ has a major drawback that it causes tooth discoloration. This study assessed discoloration of crown when various MTA-based materials were placed in the coronal aspect of the root canal. Seventy-five single-rooted, unrestored premolar teeth were selected. The teeth were randomly assigned to four experimental groups, each of $Biodentine^{(R)}$, Proroot $wMTA^{(R)}$, $Endocem^{(R)}$, $RetroMTA^{(R)}$ and one negative control groups. Color measurements were utilized by the Commission International de I'Eclairage's L*a*b* system with spectrophotometer. The color was assessed eight times : initial, 1 day, 1 week, 2 weeks, 4 weeks, 8 weeks, 12 weeks, and 16 weeks after the placement. Statistical analysis was performed using the 2-way repeated analysis of variance and Bonferroni's method with p < 0.05. Proroot $wMTA^{(R)}$ induced significant decreases in $L^*$ values during experiment period. Tooth samples from the $Endocem^{(R)}$ group presented indistinct grayish color changes. The $Biodentine^{(R)}$ and $RetroMTA^{(R)}$ showed color stability. Consequently, while Proroot $wMTA^{(R)}$ and $Endocem^{(R)}$ that contain bismuth oxide as a radiopacifier showed tooth discoloration, displayed no sign of discoloration $Biodentine^{(R)}$ and $RetroMTA^{(R)}$ that contain zirconium oxide as a radiopacifier.