• Title/Summary/Keyword: 방사선 이용통계

Search Result 565, Processing Time 0.021 seconds

협회소식

  • Korea Radioisotope Association
    • 동위원소뉴스
    • /
    • no.5 s.41
    • /
    • pp.1-1
    • /
    • 2000
  • PDF

The Development of On-Line Statistics Program for Radiation Oncology (방사선종양학과 On-line 통계처리프로그램의 개발)

  • Kim Yoon-Jong;Lee Dong-Hoon;Ji Young-Hoon;Lee Dong-Han;Jo Chul-Ku;Kim Mi-Sook;Ru Sung-Rul;Hong Seung-Hong
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.369-380
    • /
    • 2001
  • Purpose : By developing on-line statistics program to record the information of radiation oncology to share the information with internet. It is possible to supply basic reference data for administrative plans to improve radiation oncology. Materials and methods : The information of radiation oncology statistics had been collected by paper forms about 52 hospitals in the past. Now, we can input the data by internet web browsers. The statistics program used windows NT 4.0 operation system, Internal Information Server 4.0 (IIS4.0) as a web server and the Microsoft Access MDB. We used Structured Query Language (SQL), Visual Basic, VBScript and JAVAScript to display the statistics according to years and hospitals. Results : This program shows present conditions about man power, research, therapy machines, technics, brachytherapy, clinic statistics, radiation safety management, institution, quality assurance and radioisotopes in radiation oncology department. The database consists of 38 inputs and 6 outputs windows. Statistical output windows can be increased continuously according to user's need. Conclusion : We have developed statistics program to process all of the data in department of radiation oncology for reference information. Users easily could input the data by internet web browsers and share the information.

  • PDF

An Analysis and Development of the Measurement on General Knowledge Related to the Safety of Living Radiation (생활방사선안전 관련 일반지식 측정도구 개발 및 실태분석)

  • Choi, Kyoungho;Seo, Hye-Young
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.4
    • /
    • pp.205-211
    • /
    • 2022
  • Various radioactive materials exist around us. In recent years, as interest in health has increased along with the improvement of the quality of life, examinations using radiation are also increasing. This research defined aforementioned radiation as a living radiation and developed a measurement to measure general knowledge people have on it. Eighteen reliable items were developed; current status on general knowledge regarding the safety of living radiation was analyzed using the items. As a result, a group with radiation-related education got statistically higher score than a group without such education. Correlation analysis and regression analysis showed that higher attention on usual safety leads into the greater knowledge on safety of living radiation. Therefore, this research shed lights on the necessity of radiation safety-related education in current educational course in schools.

3차원 치료계획용 전산화단층촬영에서 영상증강을 위한 최적의 프로토콜에 관한 연구

  • 이상규;이석;김주호;백종걸;조정희;신동봉;박재일
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • 1. 목적 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 조영제 주입율에 따른 CT 값(hounsfield unit, H.U) 변화를 정량적으로 평가하여 최적의 영상증강효과 및 방사선치료계획을 위한 기초 프로토콜을 제시하고자 한다. 2. 대상 및 방법: 연세암센터 방사선종양학과에서 3차원 치료계획용 전산화단층촬영을 시행한 상복부(폐암)환자 20명을 대상으로 하였다. 조영제 양(130mL)은 일정하게 고정하였고, 조영제주입율을 1.2, 1.5, 2.0 mL/sec로 변화시켜가며 조영제를 주입하면서 3차원 방사선치료계획영상에 적합한 조영제주입율(contrast flow rate)과 지연시간(delay time)을 도출하였고, CT 값을 측정하여 정량적 평가를 시행하였다. 관심부위는 폐동맥과 폐정맥으로 하였다. 그리고, 환자 기본정보, 조영제주입율, H.U 등 영상증강에 영향을 미치는 인자들을 통계처리 프로그램인 SPSS를 이용하여 최적의 영상을 획득할 수 있는 기초 프로토콜을 작성하였다. 3. 결과 : 폐암환자의 전산화단층촬영영상 획득 시 3차원 방사선치료계획에 적합한 영상을 얻을 수 있는 조건중 조영제주입율은 1.5 mL/sec 이었고, 지연시간은 $60{\sim}70$초이었다. 통계처리를 수행한 결과 환자의 기본정보 및 조영제주입율 등이 영상증강에 영향을 미치는 인자임을 알 수 있었다. 본 연구에서 작성한 기초 프로토콜을 이용하여 3차원 방사선치료계획 시 정확한 종양 및 정상조직 설정이 용이하게 되어 방사선치료 효율을 극대화 할 수 있었다. 4. 결론 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 사용할 수 있는 기초적인 영상획득 프로토콜을 도출하였고, 향후 더 많은 임상경험과 정량적 평가가 수반된다면 임상에 적극 사용할 수 있을 것이라 사료된다.

  • PDF

Factors that affect the Behavior on the Radiation Safety Management for Dental Hygienists (치과위생사들의 방사선 안전관리행위에 영향을 미치는 요인)

  • Jeong, Young-Hee;Kwon, Yang-Ok;Lee, Ji-Young;Heo, Seong-Eun;Yoon, Young-Suk
    • Journal of dental hygiene science
    • /
    • v.11 no.6
    • /
    • pp.471-479
    • /
    • 2011
  • This research, which was conducted for dental hygienists, intended to check out what factors have an influence on their behaviors by measuring the level of self-efficacy and consciousness on the use of radiation, knowledge and attitude on radiation safety management(RSM). The subjects were 235 of the dental hygienists and this study performed a survey 8 May to 17 June, 2011. The survey results were as follows. 1. As a result of comparing the average of the self-efficacy according to the general characteristics, a statistically meaningful difference(p<0.05) was found according to health condition, protection facilities condition. 2. As a result of comparing the average of consciousness about radiation use according to the general characteristics, a statistically meaningful difference(p<0.05) was found according to medical institute type, protection facilities conditions. 3. As a result of comparing the average of the behaviors for RSM according to the general characteristics, a statistically meaningful difference(p<0.05) was found according to monthly income, medical institute type, whether or not education on radiation was conducted, the number of education, education type, and protection facilities condition. 4. As a result of analyzing what factors have an influence on the behaviors for RSM by employing the points of those behaviors as a dependent variable and self-efficacy, consciousness, knowledge and attitude as an independent variable in order to investigate those factors, it turned out that the factors which had a relatively larger influence on the point of behaviors were attitude and self-efficacy by that order(p<0.05). In conclusion, we believe that a variety of programs should be offered to provide knowledge on RSM as a prerequisite for improving the level of RSM behaviors by dental hygienists.

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

Estimation for Economic Scale of Radioactive Usage in Korea using Input-Output Table 2005 (2005년 산업연관표를 이용한 우리나라의 방사선 이용의 경제규모에 대한 추정 연구)

  • Kim, Yoon-Kyung
    • Journal of Korea Technology Innovation Society
    • /
    • v.13 no.4
    • /
    • pp.772-793
    • /
    • 2010
  • In this paper, author estimated economic scale of radiation usage in Korea using Input-Output table 2005 and other micro data published. This estimation focused all kind of radiation usage in whole economic activity. Estimation of economic scale is quantitative analysis for how much radiation usage increase productivity and welfare. Economic scale estimation of radiation usage in Korea 2005 is 6,297 Billion Won and it occupies 0.74% of GDP. It is smaller level compared with that of US and Japan. It is 1.5% of GDP in US (1997) and 1.2% of GDP in Japan (2005). Radiation usage in industrial sector is 5,775 Billion Won and it is 0.68% of GDP. Radiation usage in agriculture sector is 171 Billion Won and it is 0.02% of GDP. Radiation usage in medical sector is 351 Billion Won and it is 0.04% of GDP. This implied that radiation usage in industrial sector is larger than other sector. Use of medical radiology may be enlarge in the future due to population structure. The result that radiation usage occupied 0.74% of GDP arouse contribution of radiation usage in daily life. It helps people to have more understanding and public acceptance for radiation.

  • PDF

국내 원자력시설 주변의 환경방사능 분포에 관한 연구

  • Kim Ju-Yelol;Lee Byeong-Cheol
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.107-110
    • /
    • 2006
  • 국가 환경방사선/능 자동감시망과 원전주변의 환경방사선/능 감시를 통해서 연속적으로 측정 기록된 대량의 환경방사선/능 정보들이 효과적으로 활용되고 있지 않는 상황에서 환경방사선/능 정보에 내재되어 있는 공간정보 속성들을 정량적으로 해석하고 시공간적으로 예측할 필요성이 있다. 지구통계기법을 활용하면 환경방사선 감시설비가 비록 설치되어 있지 않은 지점일지라도 환경방사선/능 정보에 대한 예측이 가능하므로 향후 추가적인 감시기의 설치와 시료분석에 소요되는 시간과 비용을 절감할 수 있다. 본 연구에서는 고리, 월성, 영광, 울진 원자력발전소와 대전 한국원자력연구소 등 국내 원자력이용시설 주변 토양중의 환경방사능 분포를 감마동위원소인 $^{137}Cs$$^{40}K$을 중심으로 파악하였다.

  • PDF

A Survey of Patient Satisfaction with the use of Aloe Vera Mist for Skin Care during Radiation Therapy for Breast Cancer (유방암 방사선치료 중 피부 관리를 위한 알로에 베라 미스트 사용에 대한 환자 만족도 조사)

  • Han-A Yun;Hyo-Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.231-242
    • /
    • 2023
  • This study aims to provide basic data to reduce the incidence of radiation dermatitis and improve patient satisfaction by investigating the management status and satisfaction level of radiation dermatitis in patients undergoing radiation therapy. From October 28, 2022, to April 4, 2023, a survey was conducted on 137 breast cancer patients who received radiation therapy at G Hospital in Busan. The Radiation Therapy Oncology Group (RTOG) cutaneous acute radiotherapy toxicity score was used as the standard for measuring skin reactions, and the association between cancer stage and RTOG was analyzed. SPSS program (ver. 18.0) was used for statistical analysis. The frequency of radiation dermatitis occurrence was relatively low, with 73% in the RTOG 0-1 group and 27% in the 2-3 group. Patient satisfaction after radiation therapy varied significantly depending on the RTOG group, with lower levels of dermatitis resulting in higher satisfaction and higher levels resulting in dissatisfaction (p=0.001). Although there was no statistically significant difference in RTOG group and skin satisfaction depending on the frequency of aloe mist use (p=0.065), the group that used it 1-2 times a day (69.3%) showed a higher satisfaction level. The perceived effects of aloe mist use were statistically significant for decreasing heat sensation (p=0.001), pain (p=0.033), itching (p=0.001), and psychological stability (p=0.027), especially in the higher RTOG groups. Additionally, as cancer stage increased, the severity of radiation dermatitis also increased, which was statistically significant (p=0.001). In conclusion, radiation dermatitis is the most common side effect of radiation therapy, and it can appear in various forms depending on individual skin sensitivity and external factors during treatment. Adequate education before treatment and the use of MD Cream and aloe vera mist are recommended to reduce the incidence and manage radiation dermatitis effectively.