• Title/Summary/Keyword: 방사선 영향평가

Search Result 741, Processing Time 0.022 seconds

Differential Effects of Green Tea Polyphenol in the ${\gamma}-irradiation$ Induced Human Leukemic and Lymphoblastic Cell Damage (녹차 폴리페놀이 감마선조사에 의한 백혈병과 림프구모세포의 손상에 미치는 영향의 차이)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Min, Jung-Jun;Bom, Hee-Seung;Kim, Young-Ho;Jeong, Young-Do;Kim, Chang-Guhn
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.308-316
    • /
    • 2003
  • Purpose: The green tea polyphenol (GTPP) has been known to exert antioxidant activity as a radical scavenger as well as cancer preventive and cancer growth inhibition effect. The aim of this study was to identify whether GTPP not only potentiate the growth inhibition effect in ${\gamma}-irradiated$ human cancer cell but also exert protection action for irradiated human normal cell. Materials and Methods: GTPP (80% catechin including >45% EGCG) added in the HL60, human leukemia, and NC37, human lymphoblast, before irradiation. After establishing the amount of GTPP and the dose of radiation, the cells were treated with the GTPP for 6 hours and irradiated with the determined doses. Results: Viability when $10{\mu}g/ml$ GTPP added before ${\gamma}-irradiation$ with 1 Gy to NC37 cells was not different in comparison with control but it when was irradiated with 3 Gy significantly different (1 Gy;P=0.126, 3 Gy;P=0.010). $20{\mu}g/ml$ GTPP did not show significant difference in both NC37 cells irradiated with 1 Gy and 3 Gy (1 Gy;P=0.946, 3 Gy;P=0.096). Viabilities were significantly decreased with concentration of additional GTPP in HL60 with 1 or 3 Gy (1 Gy $69.0{\pm}1.7%\;vs\;42.4{\pm}1.3%,\;3\;Gy;\;66.9{\pm}3.9%\;vs\;44.2{\pm}1.6%$). Conclusion: In vitro study, we certified that when the cells were irradiated with dose below 3 Gy, GTPP provide not only anticancerous effect against cancer cells but also radioprotective effect in normal cells simultaneously. Theses results suggest the possibility that consumption of green tea could give the radioprotective effect and maximize the effect on internal radiation such as radioiodine therapy concomitantly.

A Basic Study on the Radiological Characteristics and Disposal Methods of NORM Wastes (공정부산물의 방사선적 특성과 처분방안에 관한 기본 연구)

  • Jeong, Jongtae;Baik, Min-Hoon;Park, Chung-Kyun;Park, Tae-Jin;Ko, Nak-Youl;Yoon, Ki Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.3
    • /
    • pp.217-233
    • /
    • 2014
  • Securing the radiological safety is a prerequisite for the safe management of the naturally occurring radioactive materials (NORM) which cannot be reused. This becomes a crucial focus of our R&D efforts upon the implementation of the Act on Protective Action Guidelines against Radiation in the Natural Environment. To secure the safety, the establishment of technical bases and procedures for securing radiological safety related to the disposal of NORM is required. Thus, it is necessary to analyze the characteristics, to collect the data, to have the radiological safety assessment methodologies and tools, to investigate disposal methods and facilities, and to study the effects of the input data on the safety for the NORM wastes. Here, we assess the environmental impact of the NORM waste disposal with respect to the major domestic and foreign NORM characteristics. The data associated with major industries are collected/analyzed and the status of disposal facilities and methodologies relevant to the NORM wastes is investigated. We also suggest the conceptual design concept of a landfill disposal facility and the management plan with respect to the major NORM wastes characteristics. The radionuclide pathways are identified for the atmospheric transport and leachate release and the environmental impact assessment methodology for the NORM waste disposal is established using a relevant code. The assessment and analysis on the exposure doses and excessive cancer risks for the NORM waste disposal are performed using the characteristics of the representative domestic NORM wastes including flying ash, phosphor gypsum, and redmud. The results show that the exposure dose and the excessive cancer risks are very low to consider any radiation effects. This study will contribute to development in the areas of the regulatory technology for securing radiological safety relevant to NORM waste disposal and to the implementation technology for the Act.

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Association of Left Ventricular Diastolic Dysfunction and Epicardial Adipose Tissue (좌심실의 이완기장애와 심장외막지방두께와의 연관성 연구)

  • Kim, Sun-Hwa;Kang, se-sik;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.511-519
    • /
    • 2016
  • Left ventricular diastolic dysfunction is mostly observed in patients with cardiac disease, such as myocardial ischemia or LVH, but linking is usually observed in healthy people without heart disease. Evaluation of left ventricular diastolic failure in normal cardiac output(systolic function) conditions can affect the progress and prognosis of heart failure. The direct relevance to the epicardial adipose tissue metabolism in cardiovascular engine for generating a bioactive moleculer, which leads to dysfunction of the later had a direct effect on myocardial heart. The purpose of this study is to measure the thickness of the epicardial adipose tissue was to study the relevance of the assessment of diastolic dysfunction in systolic function in normal conditions. Results epicardial adipose tissue thickness and diastolic dysfunction was analyzed to have a high correlation in a statistically significant level. In particular, the epicardial adipose tissue thickness measured at the measuring section EAT2 and diastolic function evaluation E' was found to have a high correlation. Thus epicardial adipose tissue thickness variation is believed can be used as a predictor to evaluate the left ventricular diastolic dysfunction.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.301-305
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelfth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.391-394
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelveth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

Imaging Study of Fine Pixel Scintillator Block using Reflector on the Side of Light Guide (광가이드 측면 반사체 사용을 통한 미세 픽셀 섬광체 블록의 영상화 연구)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.671-677
    • /
    • 2023
  • When a scintillator block is constructed using fine scintillator pixels, the scintillator block located at the edge of the scintillator block results in overlapping images. To solve this problem, a light guide was inserted between the scintillator block and the photosensor, and images of all scintillation pixels were separated and acquired. However, loss of light may occur through the light guide, which eventually affects the quality of the image due to a decrease in energy resolution. Therefore, in this study, a detector was designed that can separate scintilltion pixels better by using a reflector on the side of the light guide and can secre excellent energy resolution by minimizing light loss. For comparative evaluation with previous studies, flood images were obtained through DETECT2000 capable of light simulation, and the degree of separation and light collection rate were evaluated. When a reflector was used on the side of the light guide, all materials showed excellent separation regardless of the material of the light guide, which showed better separation results than previous studies. In addition, the light collection rate was more that five times better when the reflector was applied than when it wa not. If this detector is applied to a small animal positron emission tomography, it will be possilbe to secre excellent image quality through excellent spatial resolution and energy resolution.

Results of Coventional Radiotherapy for Carcinomas of the Tonsillar Region (편도암의 방사선 치료 성적)

  • Nah Byung Sik;Nam Taek Keun;Ahn Sung Ja;Chung Woong Ki
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 1997
  • of $PLC-\gamma$ 1 activity. Results : In the immunohistochemistry, the expression of $PLC-\beta$ was negative for all grnups. The expression of $PLC-\gamma$ 1 was highest in the group III followed by group II in the proliferative zone of mucosa. The expression of PKC-01 was strong1y positive in group I followed by group II in the damaged surface epithelium. The above findings were also confirmed in the immunoblotting study. In the irnrnunoblotting study, the expressions of $PLC-\beta,\;PLC-\gamma\;1,\;and\;PLC-\delta$ were the same as the results of immunohistochemistry The expression of ras oncoprotein was weakly Positive in groups II, III and IV. The of EGFR was the highest in the group II, III, followed by group W and the expression of PKC was weakly positive in the group II and III. Conclusion : $PLC-\gamma$ 1 mediated signal transduction including ras oncoprotein, EGFR, and PKC play a significant role irL mucosal regeneration after irradiation. $PLC-\delta$ 1 mediated signal transduction might have an important role in mucosal damage after irradiation. Further studies will be necessary to confirm the signal transduction mediating the $PLC-\delta$ 1.

  • PDF

Evaluation of the Effect of Solvent on the Preparation of PVBC-g-ETFE Film by a Pre-irradiation Method (전조사법에 의한 PVBC-g-ETFE 필름 제조 시 용매의 영향 평가)

  • Lee, Sun-Young;Song, Ju-Myung;Sohn, Joon-Yong;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.610-614
    • /
    • 2011
  • In this study, the effect of solvent on the pre-irradiation grafting of VBC(vinylbenzyl chloride) onto a ETFE(polyethylene-co-tetrafluoroethylene) was evaluated. ETFE film was irradiated to generate radical species onto its backbone chain. Each irradiated film was immersed into VBC monomer mixtures diluted with various solvents such as toluene, heptane, and isopropanol etc. for grafting process and then the degree of grafting of each film was measured. FTIR analysis confirmed that the VBC-g-ETFE film was successful prepared. For the films prepared in the various solvents, the mechanical strength and the distribution pattern of the graft polymer over the cross-section of the films were measured and the effect of solvent was evaluated.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.