• Title/Summary/Keyword: 방사선 영향평가

Search Result 741, Processing Time 0.028 seconds

Acridine Orange Stained Micronucleus Assay in Human B and T-lymphocytes after Low Dose ${\gamma}-irradiation$ (아크리딘 오렌지 형광염색법을 이용한 저선량 감마선 유도 말초혈액 B와 T-림프구 미소핵 분석)

  • Choi, Jeong-Mi;Kim, Hee-Sun;Yang, Kwang-Hee;Kim, Cha-Soon;Lim, Yong-Khi;Kim, Chong-Soon;Woon, Jae-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • Firstly, we compared the two staining techniques, Giemsa and Acridine orange, to determine micronuclei on samples of cultures of five healthy human peripheral blood lymphocytes after ${\gamma}-irradiation\;(^{137}Cs)$ in dose ranges of 0 to 800cGy. It was found that the Acridine orange staining method gives more reliable results than the usual Giemsa staining method in micronucleus tests. Moreover, the frequency of micronuclei in cytokinesis-blocked human B-lymphocytes was studied after in vitro irradiation in dose ranges of 0 to 50cGy. After setting and separating the B-lymphocytes, the frequency of radiation-induced micronuclei were observed as the end-point markers for the low-dose radiation dosimetry after staining with Giemsa and Acridine orange dyes. The micronuclei frequency in B-lymphocytes was significantly elevated from 10 to 30cGy ${\gamma}-irradiation$. The determination of micronuclei in B-lymphocytes after staining with Acridine orange was higher than that of Giemsa. The frequency of micronuclei in B-lymphocytes was observed to be at least two times higher than those of T-lymphocytes Giemsa in dose increasing. Therefore, the determination of low-dose radiation-induced micronuclei in B-lymphocytes after staining with Acridine orange is likely to have the greatest potential in the estimation of low dose radiation exposure.

Dose Evaluation of Childhood Leukemia in Total Body Irradiation (소아백혈병의 전신방사선조사시 선량평가)

  • Lee, Dongyeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Donghyun;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.259-264
    • /
    • 2013
  • Total body irradiation in the treatment of childhood leukemia, which is one of the pre-treatment with stem cell transplantation is being used, the current organization using compensators are treated. However, under the terms of the compensator organization long-term impact on the human body, it is difficult to assess directly. In this study, we use the mathematical simulation of radiation exposures body energy and the distance to the crew and the patient (source surface distance, SSD), and patients with tissue compensators change of the distance along the body of the organ doses were evaluated. As a result, the surface dose of energy 4 MV, SSD 280 cm, tissue compensators and the patient when the distance 30 cm 5.84 G / min showed the highest levels. In addition, patients with tissue compensators and the distance apart when 30 cm TBI represents the ideal dose distribution was found.

Regulation of Apoptosis and Cell Cycle in Irradiated Mouse Brain (마우스의 대뇌조직에서 방사선에 의한 아포토시스와 세포주기의 조절)

  • Oh, Won-Yong;Song, Mi-Hee;Chung, Eun-Ji;Seong, Jin-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.146-152
    • /
    • 2001
  • Purpose : To investigate the regulation of apoptosis and cell cycle in mouse brain irradiation. Materials and Methods : 8-week old male mice, C57B1/6J were given whole body $\gamma-radiation$ with a single dose of 25 Gy using Cobalt 60 irradiator. At different times 1, 2, 4, 8 and 24hr after irradiation, mice were killed and brain tissues were collected. Apoptotic cells were scored by TUNEL assay. Expression of p53, Bcl-2, and Bax and cell cycle regulating molecules; cyclins Bl, Dl, E and cdk2, cdk4, $p34^{cdc2}$ were analysed by Western blotting. Cell cycle was analysed by Flow cytometry. Results : The peak of radiation induced apoptosis is shown at 8 hour after radiation. With a single 25 Gy irradiation, the peak of apoptotic index in C57B1/6J is $24.0{\pm}0.25$ (p<0.05) at 8 hour after radiation. Radiation upregulated the expression of p53/tubulin, Bax/tubulin, and Bcl-2/tubulin with 1.3, 1.1 and 1.45 fold increase, respectively were shown at the peak level at 8 hour after radiation. The levels of cell cycle regulating molecules after radiation are not changed significantly except cyclin D1 with 1.3 fold increase. Fractions of Go-Gl, G2-M and S phase in the cell cycle does not specific changes by time. Conclusion : In mouse brain tissue, radiation induced apoptosis is particularly shown in a specific area, subependyma. These results and lack of radiation induced changes in cell cycle ofter better understanding of radiation response of noraml brain tissue.

  • PDF

Effect of Antioxidant and Irradiation Treatment under Freezing Temperature Conditions on Physicochemical and Sensory Properties of Tarakjuk (Milk Porridge) (항산화제 첨가 및 냉동 방사선 조사 병용처리가 타락죽의 이화학적 및 관능적 품질에 미치는 영향)

  • Han, In-Jun;Song, Beom-Seok;Kim, Jae-Hun;Park, Jong-Heum;Lee, Ju-Woon;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.12
    • /
    • pp.1750-1756
    • /
    • 2011
  • This study evaluated the effect of antioxidants treatment; (Vit. C and E) on the physicochemical and sensory properties of Tarakjuk treated with gamma-irradiation under two different temperature conditions, e.g. room and frozen temperatures. In samples of Tarakjuk irradiated at room temperature, Vit. C gradually decreased the pH level as the concentration increased (p<0.05), whereas Vit. E did not. Addition of both Vit. C and E to Tarakjuk decreased TBA (2-thiobarbituric acid) value while also increasing viscosity. However, these antioxidants did not cause any change in Hunter's color values. Sensory properties showed that Vit. C and E significantly improved the overall acceptability of Tarakjuk, and the addition of 0.1% each Vit. C and E was best treatment. In samples of Tarakjuk subjected to combined treatment with antioxidants and irradiation under frozen temperature conditions, Vit. C and E were effective in decreasing TBA value, improving viscosity, and maintaining sensory quality. Especially, co-treatment with 0.1% Vit. C and E augmented the observed effect (p<0.05). Therefore, combined treatment with antioxidants and irradiation under frozen temperature conditions could improve the final sensory quality of gamma-irradiated Tarakjuk.

A Study on the Food Consumption Rates for Off-site Radiological Dose Assessment around Korean Nuclear Power Plants (국내 원자력발전소 주변 주민의 방사선량 평가를 위한 음식물 섭취율 설정 연구)

  • Lee, Gab-Bock;Chung, Yang-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.183-196
    • /
    • 2008
  • The internal dose by food consumption mostly accounts for radiological dose of public around nuclear power plants (NPPs). But, food consumption rates applied to off-site dose calculation in Korea which are the result of field investigation around Kori NPP by the KAERI (Korea Atomic Energy Research Institute) in 1988, are not able to reflect the latest dietary characteristics of Korean. The food consumption rates to be used for radiological dose assessment in Korea are based on the maximum individual of US NRC (Nuclear Regulatory Commssion) Regulatory Guide 1.109. However, the representative individual of the critical group is considered in the recent ICRP (International Commission on Radiological Protection) recommendation and European nations' practice. Therefore, the study on the re-establishment of the food consumption rates for individual around nuclear power plant sites in Korea was carried out to reflect on the recent change of the Korean dietary characteristics and to apply the representative individual of critical group to domestic regulations. The Ministry of Health and Welfare Affairs has investigated the food and nutrition of nations every 3 years based on the Law of National Health Improvement. The statistical data such as mean, standard deviation, various percentile values about food consumption rates to be used for the representative individual of the critical group were analyzed by using the raw data of the national food consumption survey in $2001{\sim}2002$. Also, the food consumption rates for maximum individual are re-estimated.

Usefulness Evaluation of Mammographic Image (유방촬영 영상의 유용성 평가)

  • Kang, Se-Ssik
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.49-54
    • /
    • 2004
  • Purpose : To valuate the usefulness of mammographic image by using phantom 1,2 to controls the enhancement of image quality. Procedure : Set up same equipments for experiment (all the qualification must be the same). Control group and 4 other experiment the developing mammographys by using the image system with film/intensifying screen and distribute marks on each test objects of phantom 1, 2. Result : The results of the experiment using phantom 1, 2 on control group and 4 others are : 1. phantom 1's valuation with 3 items. - control group received 29 out of 32 - group A received 25 - group B received 16 - group C received 11.5 - group D received 28.5 The evaluation shows that the system has proved to display excellent image quality except group B and C. 2. Phantom 2's valuation with 4 items. - control group received 38 out of 38 - group A received 30 - group B received 16 - group C received 12.5 - group D received 38 Even with phantom 2, group B and C has displayed poor image quality. Conclusion : Both experiments using phantom 1 and 2 have shown that the most strong factor that control and influence the image quality are the filming equipments. Especially, the developing system has most powerful influence above all.

  • PDF

Radiation resistant Characteristics of Fiber Bragg Grating Sensors made with 800-nm femtosecond laser (800nm급 펨토초 레이저로 제작된 FBG 센서의 내방사선 특성)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Sohn, Ik-Bu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.711-713
    • /
    • 2017
  • Fiber Brag grating sensors were written in standard Ge-doped telecom optical fiber (Corning SMF-28) using an 800nm femtosecond laser and a phase mask. It were exposed to gamma-radiation up to a dose of 100 kGy to evaluate the radiation effect. The fs-FBG-2 sensor showed incomplete optical characteristics during irradiation, but the fs-FBG-1 sensor showed excellent radiation resistance with Bragg wavelength shift(BWS) of less than 10pm at a dose of 100 kGy.

  • PDF

A Study on the Evaluation of Radiological Effects on Workers from Air Contamination in Radioactive Waste Treatment Facilities (방사성 액체폐기물 처리 시설 내 공기오염에 의한 작업종사자 방사선학적 영향 평가에 대한 연구)

  • Min-Ho Lee;Woo-Beom Ha;Sang-Heon Lee;Jong-Soon Song
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.147-153
    • /
    • 2024
  • Radioactive liquid waste generated during operation and overhaul is collected and reused through the radioactive liquid waste treatment system and continuous monitoring system in the nuclear power plant or discharged to the outside if it satisfies the limit within the control and monitoring. However, there are concerns about boric acid management, which controls the power output of nuclear power plants in radioactive liquid waste. Due to the behavior of boric acid, it is difficult to remove it in the existing liquid radwaste system, and the concentration of boric acid water discharged tends to be higher than the natural state of 5 ppm, so additional facilities should be considered. Therefore, this study aims to evaluate the radiological effects of radioactive waste treatment facilities that are under development and use them as a basis for managing worker exposure and evaluating the safety of facilities in the future.

Radiation Dose Evaluation for Metallization Process Facility of Spent Fuel (사용후핵연료 금속전환공정시설의 방사선환경영향평가)

  • 국동학;정원명;구정회;조일제;이은표;유길성
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.596-600
    • /
    • 2003
  • The Advanced spent fuel Conditioning Process(ACP) is under development for the effective management of spent fuel which had been generated in nuclear plants. The ACP needs a hot cell where most operations will be peformed. To give priority to the environment safety, radiation doses evaluation for the radioactive nuclides were preliminarily peformed in both normal operation and accident case. The evaluation result shows a safe margin for regulation limits and SAR limit of IMEF where this facility will be constructed.

  • PDF

Evaluation of Breast Dose in Mammography for Breast Implant Patient using a Monte Carlo Simulation (몬테칼로 모의모사를 이용한 유방성형술 환자의 유방선량평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.253-259
    • /
    • 2020
  • Mammography has the advantage of being economical, simple and effective in detecting microcalcification, but breast is a highly sensitive organ and is accompanied by the risk of an over-exposure. While accurate dose assessments are important to prevent this, current breast dose assessments are limited to breast implant patients. This purpose of this study was to identify dose variations due to tube voltages by forming a mock-up with breast implants for an accurate dosimetric assessment on breast implant patients. As a result, doses from the presence of breast implants were smaller than those from the absence of the mammal. As the result of the change of the voltage to 26, 28, 30, and 32 kV, the imcreased tube voltage included larger dose regardless of the presence of Breast implant. Therefore, it is believed that diagnosis recommendations for breast implants will be possible if further studies on internal and external bioretical imaging and quality assessment are carried out as the basis for this study.