• Title/Summary/Keyword: 방사선 영향평가

Search Result 741, Processing Time 0.023 seconds

Effects of Low-Dose Fractionated Total Body Irradiation on Murine Immune System (마우스에서 전신 저선량 분할 방사선 조사에 의한 면역학적 변화 평가)

  • Kim, Mi-Hyoung;Rhu, Sang-Young;Lim, Dae-Seog;Song, Jie-Young
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • Along with the wide use of radiotherapy in cancer treatment, there is growing interest in beneficial effect of low-dose irradiation (LDI) in cancer therapy. Therefore, we investigate how LDI affects immune responses in mice model. Total body irradiation (TBI) on C57BL/6 mice was given at low-dose rate of $1mGy{\cdot}min^{-1}$ using $^{137}Cs$ source at three times for consecutive three days. Hematological examination, total cell numbers of spleen, populations and characteristics of splenocytes were determined. Total numbers of RBC or platelet in irradiated mice showed no significant changes. WBC counts were decreased in a dose-dependent manner 2 days after TBI, however, these differences are gradually waned until 28 days. Dose-dependent decrease in the number of splenocytes of TBI mice at day 2 was also improved as time progressed. While the level of Foxp3 mRNA was decreased, the frequency of $CD4^+$ T cells and $CD69^+$ cells in spleen was increased at day 2 and 14. Fractionated low-dose TBI on mice exhibited normal body weight with no distinguishable behavior during whole experimental periods. These results suggest that some parameters of immune system could be altered and evaluated by fractionated low-dose TBI and be used to broaden boundary of low dose radiation research.

A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital (방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.249-255
    • /
    • 2023
  • In this study, radiation exposure doses were measured in the course of clinical practice of radiation workers, radiological technologists in the radiation-related worker group, and preliminary-radiological technologists who were classified as frequent visitors. Radiological technologists who worked in the radiation area of C University Hospital in Incheon for a year from January 2021 and 121 students who completed clinical practice at the same medical institution from July 1 to August 31 were the subjects of the study. The nominal risk factor based on ICRP 103 was used to evaluate the probability of side effects due to the exposure dose to the lungs, which are organs at risk of damage due to radiation exposure dose. During the clinical practice period, radiology students, who were classified as frequent visitors, had a surface dose of 0.98 ± 0.14 mSv and a deep dose of 0.93 ± 0.14 mSv. In other words, 6.7 per 1,000,000 for shallow dose and 6.4 per 1,000,000 for deep dose were found to have side effects due to exposure to the lungs. This is a value in terms of exposure dose in one year. Considering that the radiation (science) education course is 3 or 4 years, systematic management and attention to prospective radiation workers who are going to clinical practice are required, and the stochastic effect of radiation In relation to this, it is considered that it will be used as basic data for radiation safety management.

Assessment of Body Condition in Amphibians Using Radiography: Relationship between Bone Mineral Density and Food Resource Availability (방사선 촬영 기법을 이용한 양서류 신체상태 평가: 골밀도와 먹이 자원 가용성 간의 상관 관계)

  • Park, Jun Kyu;Do, Yuno
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.4
    • /
    • pp.358-365
    • /
    • 2019
  • We measured the body composition, including bone mineral density (BMD) and food resource availability using dual energy X-ray absorptiometry and the carbon and nitrogen stable isotope ratios of body condition of 4 anuran species(Hyla japonica, Glandirana rugosa, Pelophylax nigromaculatus, Lithobates catesbeianus) in South Korea. Additionally, the carbon and nitrogen stable isotope ratios were employed to determine the food resource availability of anurans. We figured out the relationship between the body composition, including BMDs and food resource availability. The body composition and BMDs did not differ between male and female while there was difference among the species. Food resource availability and BMDs were the highest in L. catesbeianus, the lowest in H. japonica. BMDs tended to increase with higher food resource availability. Body composition and BMDs, which represent the body condition of an individual, can be used as an ecological indicator to assess the stability of the habitat of anurans.

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

Assessment of Relative Importance to the Early Effect of Released Radionuclides During Nuclear Power Plant Accident (원전 사고시 방출핵종의 조기 영향에 대한 상대적 중요도 평가)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.78-87
    • /
    • 1988
  • This article suggests the radionuclides which should be considered more important to the offsite consequence assesment during a nuclear power plant accident. For this purpose, the relative importance to the early health effects of released radionuclides on the major organs during the accident is estimated under the assumption of the same release fraction. The inventories of the 25 elements, 54 nuclides selected in the Reactor Safety Study are calculated by ORIGEN 2 code. The organs of interest in the estimation are G. I. track, bone marrow, thyroid and lung. The result shows the relative potential importance of radionuclides as follows: For G.I. track, Np, Ce, Ru, Y, and Zr are of importance in sequence, Np, I, La, Sr, Ba for bone marrow, I and Te for thyroid, Cm, Ce, Ru, Pu, Zr for lung. In addition to iodine and noble gases, therefore, the potential contribution of those nuclides listed above to the offsite consequences should not be overlooked for some accidents of particular sequence.

  • PDF

Radiotherapy for the Low-grade Astrocytomas (양성 성상세포종의 방사선치료)

  • Kim, Dae-Yong;Kim, Il-Han;Chi, Je-Geun
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Purpose : To evaluate the efficacy of radiotherapy for the low-grade astrocy-tomas and confirm the variables influencing treatment results. Materials and Methods : Forty-six patients with low-grade astrocytoma received radiotherapy after surgical removal (36 patients) or biopsy (10 patients) from 1979 to 1990. Twenty patients had grade I histology and 26 had grade II. External radiotherapy was done by conventional schedule with the total dose of 45 to 60 Gy (median: 54 Gy). The median follow-up period was 5 years. Results : The 2- and 5-year survival rates were $80\%$ and $72\%$, respectively and the 2- and 5-year progression-free survival was $75\%$ and $63\%$, respectively. The survival was influenced significantly by the histologic grade, the histologic type, and performance status. Major complication was not found. Conclusion: In spite of good survival, the local failure was still the major problem. Age and the extent of surgery as well as three favorable factors should be considered in the future treatments.

  • PDF

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Practical Radiation Safety Control: (II) Application of Numerical Guidance for the Discharges of Radioactive Gaseous and Liquid Effluents (방사선안전관리 실무: (II) 배기중 및 배수중 배출관리기준의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.61-64
    • /
    • 2014
  • Radioactive materials are in use and have many applications from the generation of electricity to the purposes of research, industry and medicine such as diagnosis and therapy. In the course of their use some of radioactive substances may be discharged into the environment from facilities using the unsealed radioactive materials, which are main artificial sources occurring the public exposure. Discharges are in the form of gases, particles or liquids. This paper provides procedures to estimate the level of the public exposure based on the conservative assumptions and simple calculations in the facility using unsealed liquid sources. They consist of two processes; (1) to calculate maximum concentration of gaseous effluents discharged through the exhaust pipe and average concentration of liquid effluents discharged through the drain of the storage tank, (2) to compare each of them to numerical guidances for the discharges of radioactive gaseous and liquid effluents mentioned in the related notification. For this purpose followings are assumed properly; daily usage, form and dispersion rate of radionuclides, daily amount of radioactive liquid waste and exhaust and drainage equipment. The procedures are readily applicable to evaluate environmental effects by planned effluent discharges from facilities using the unsealed radioactive materials. In addition they may be utilized to obtain practical requirements for radiation safety control necessary for the reductions of the public exposure.

Assessment of Nucleus-DNA Damage in Red Pepper Cells Treated with γ-Radiation through Comet Assay (Comet 분석을 통한 방사선처리 고추세포의 핵 DNA 손상평가)

  • An, Jung-Hee;Back, Myung-Hwa;Kim, Jae-Sung;Jeong, Jeong-Hag;Kwon, Soon-Tae
    • Journal of Plant Biotechnology
    • /
    • v.31 no.3
    • /
    • pp.225-230
    • /
    • 2004
  • We employed single cell gel electrophoresis method (comet assay) to analyze the degree of nucleus-DNA damage in the leaves of red pepper (Capsicum annuum L.) seedlings exposed to $^{60}$ CO v-radiation stress. Nucleus-DNA damage was measured as the ratio of tail length (T) to head length (H) in individual comet image isolated from pepper leaf cell. The T/H ratio of control-cells and treated-cells at 50 or 100 Gy were 1.28 and 3.54 or 3.39, respectively, suggesting that nuclei of pepper cells were severely damaged in the integrity of DNA strand by the treatment of enhanced v-radiation. The percentage of head-DNA in control-cells was 76.8%, whereas those of 50 and 100 Gy treated-cells were 55.9% and 59.9%, respectively. Pretreatment of low dose (4 to 20 Gy) radiation to seeds decreased DNA-damage in the leaves of seedlings treated with high dose radiation at 50 or 100 Gy. In this experiment, we developed a sensitive, reliable and rapid method for evaluating genotoxic effect in the nuclei of plant cells by employing comet assay.

Application of Total Variation Algorithm in X-ray Phantom Image with Various Added Filter Thickness : GATE Simulation Study (다양한 두께의 부가 여과판을 적용한 X-선 영상에서의 Total Variation 알고리즘 적용 : GATE 시뮬레이션 연구)

  • Park, Taeil;Jang, Sujong;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.773-778
    • /
    • 2019
  • Images using X-rays are essential to diagnosis, but noise is inevitable in the image. To compensate for this, a total variation (TV) algorithm was presented to reduce the patient's exposure dose while increasing the quality of the images. The purpose of this study is to verify the effect on the image quality in radiographic imaging according to the thickness of the additional filtration plate through simulation, and to evaluate the usefulness of the TV algorithm. By using the Geant4 Application for Tomographic Emissions (GATE) simulation image, the actual size, shape and material of the Polymethylmethacrylate (PMMA) phantom were identical, the contrast to noise ratio (CNR) and coefficient of variation (COV) were compared. The results showed that the CNR value was the highest and the COV the lowest when applying the TV algorithm. In addition, we can acquire superior CNR and COV results with 0 mm Al in all algorithm cases.