• Title/Summary/Keyword: 방사선 신호처리

Search Result 71, Processing Time 0.027 seconds

Application of Wiener filter to Chest CR images (흉부 CR영상에 대한 위너필터의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.519-524
    • /
    • 2018
  • Chest examinations and mass chest examinations using the CR(computed radiography) System are frequently used clinically. a factor that degrades image quality in the acquisition process is the use of unused IPs long times. this paper addresses the estimation of winer filter and improved wiener filter to restoration of Chest CR images Experimental results show that the proposed method can reduce noise. in low noise variation image wiener method was excellent than improved method and the result was the opposite at high noise varience. the application of algorithms to chest CR images effectively eliminates noise. the classic Wiener filter was better than the improved method. Multiple patients examined during the process without any erase IP(image plate) process, The proposed algorithm determines that the images can be restored to a good quality and will help to read the images.

A Study on Maximizing the Matching Ratio of Scintillation Pixels and Photosensors of PET Detector using a Small Number of Photosensors (적은 수의 광센서를 사용한 PET 검출기의 섬광 픽셀과 광센서 매칭 비율의 최대화 연구)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.749-754
    • /
    • 2021
  • In order to maximize the matching ratio between the scintillation pixel and the photosensor of the PET detector using a small number of photosensor, various arrays of scintillation pixels and four photosensors were used. The array of scintillation pixels consisted of six cases from 6 × 6 to 11 × 11. The distance between the photosensors was applied equally to all scintillation pixels, and the arrangement was expanded by reducing the size of scintillation pixel. DETECT2000 capable of light simulation was used to acquire flood images of the designed PET detectors. At the center of each scintillation pixel array, light generated through the interaction between extinction radiation and scintillation pixels was generated, and the light was detected through for four photosensors, and then a flood image was reconstructed. Through the reconstructed flood image, we found the largest arrangement in which all the scintillation pixels can be distinguished. As a result, it was possible to distinguish all the scintillation pixels in the flood image of 8 × 8 scintillation pixel array, and from the 9 × 9 scintillation pixel flood image, the two edge scintillation pixels overlapped and appeared in the image. At this time, the matching ratio between the scintillation pixel and the photosensor was 16:1. When a PET system is constructed using this detector, the number of photosensors used is reduced and the cost of the oveall system is expected to be reduced through the simplification of the signal processing circuit.

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images (X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법)

  • Kim, Hyunggue;Jung, Joongeun;Lee, Jihyun;Park, Joonhyuk;Seo, Jisu;Kim, Hojoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.4
    • /
    • pp.171-178
    • /
    • 2019
  • The use of anti-scatter grids in radiographic imaging has the advantage of preventing the image distortion caused by scattered radiation. However, it carries the side effect of leaving artifacts in the X-ray image. In this paper, we propose a grid line suppression technique using discrete cosine transform(DCT). In X-ray images, the grid lines have different characteristics depending on the shape of the object and the area of the image. To solve this problem, we adopt the DCT transform based on a dynamic segmentation, and propose a filter transfer function for each individual segment. An algorithm for detecting the band of grid lines in frequency domain and a band stop filter(BSF) with a filter transfer function of a combination of Kaiser window and Butterworth filter have been proposed. To solve the blocking effects, we present a method to determine the pixel values using multiple structured images. The validity of the proposed theory has been evaluated from the experimental results using 140 X-ray images.

Development of PET Detector Module Measuring DOI using Multiple Reflectors (여러 반사체를 사용한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Kim, Neung Gyun;Kim, Gu;Kwak, Jong Hyeok;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.825-830
    • /
    • 2019
  • A detector module measuring a depth of interaction was developed using silicon photomultiplier (SiPM) and two layers of scintillation crystal array treated with multiple reflectors. When reconstructing an image based on a signal obtained by using different types of reflector of each layer, the interaction positions of scintillation pixels and gamma rays could be tracked by utilizing the feature that all scintillation pixels were recorded at different positions. The bottom layer uses a specular reflector, and the top layer uses a diffuse reflector to differently process the size of the signal obtained from the SiPM. The optical grease was used to recude the sharp refractive index change between the layers of scintillator and the SiPM. The signals obtained from the 16 SiPMs were reduced to four signals using the Anger equations, and the images were reconstructed using them. All the scintillation pixels composed of the two layers appeared in the reconstructed image, which distinguished the layer where the scintillation pixels and gamma rays interacted. If the detectors, which measure the interaction depth of two layers using different reflectors, will be applied to preclinical positron emission tomography, the degradation of spatial resolution appearing outside the field of interest could be solved.

A Parametric Study of Pulsed Gamma-ray Detectors Based on Si Epi-Wafer (실리콘 에피-웨이퍼 기반의 펄스감마선 검출센서 최적화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol;Cho, Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1777-1783
    • /
    • 2014
  • In this paper, we designed and fabricated a high-speed semiconductor sensor for use in power control devices and analyzed the characteristics with pulsed radiation tests. At first, radiation sensitive circular Si PIN diodes with various diameters(0.1 mm ~5.0 mm) were designed and fabricated using Si epitaxial wafer, which has a $42{\mu}m$ thick intrinsic layer. The reverse leakage current of the diode with a radius of 2 mm at a reverse bias of 30 V was about 20.4 nA. To investigate the characteristic responses of the developed diodes, the pulsed gamma-radiation tests were performed with the intensity of 4.88E8 rad(Si)/sec. From the test results showing that the output currents and the rising speeds have a linear relationship with the area of the sensors, we decided that the optimal condition took place at a 2 mm diameter. Next, for the selected 2 mm diodes, dose rate tests with a range of 2.47E8 rad(Si)/sec to 6.21E8 rad(Si)/sec were performed. From the results, which showed linear characteristics with the radiation intensity, a large amount of photocurrent over 60mA, and a high speed response under 350ns without saturation, we can conclude that the our developed PIN diode can be a good candidate for the sensor of power control devices.

Photovoltaic Generation System Control Using Space Vector PWM Method (공간벡터 PWM 방식을 이용한 태양광 발전 시스템 제어)

  • Cho, Moon-Taek;Choi, Hae-Gill;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.31-37
    • /
    • 2010
  • In this paper, a photovoltaic system is designed with PWM(Pulse Width Modulation) voltage source inverter. Proposed synchronous signal and control signal was processed by 56F8323 microprocessor for stable modulation. The PWM voltage source inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power, from 10 to 20[%]. The PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In addition, I connected extra power to the system through operation the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and PWM voltage inverter can be synchronized. In the system of this research showed good results after being controlled in order to provide stable power to the load and the system through maintaining and low output power of harmonics.

Photovoltaic Generation System Design for Controlling the Temperature and Humidity of Hospital (병원내 온도와 습도조절을 위한 태양광 발전 시스템 설계)

  • Cho, Moon-Taek;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.127-134
    • /
    • 2011
  • In this paper we propose an improved PV generation systems. Improved systems for temperature and humidity controlled heating and air conditioning offers a pleasant environment within the building, set up chopper and consists of a PWM voltage type inverter. The proposed system is stable modulation for a one-chip microprocessor using the synchronous signal and control signals was treated. The proposed system is a PWM voltage type inverter and phase of the synchronous to the grid voltage to detect the system voltage and inverter output to drive the statue, so surplus power to connection was able to, certain buildings such as buildings or hospitals, temperature and humidity sensor is applied to the good dynamic characteristic could be obtained. In addition, the system was applied to the high power factor and low-frequency harmonics by maintaining the output load and grid to power to be supplied to a stable control could get a good result.

Artifacts in Digital Radiography (디지털 방사선 시스템에서 발생하는 Artifact)

  • Min, Jung-Whan;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.375-381
    • /
    • 2015
  • Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient's health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user didn't have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.