• Title/Summary/Keyword: 방사선 기술

Search Result 2,671, Processing Time 0.043 seconds

KCCH Medical Cyclotron Operation for Neutron Therapy and Isotope Production (1989) - A Technical Report - (중성자 치료와 동위원소 생산을 위한 KCCH 의학용 싸이클로트론의 운영 (1989))

  • Kim, Byung-Mun;Kim, Young-Sear;Bak, Joo-Shik;Lee, Jong-Du;Yoo, Seong-Yul;Koh, Kyung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 1990
  • After four years of planning, equipment acquisition, facility construction and beam testing, the KCCH cyclotron facility was put into operation in November1986. Now the KCCH cyclotron(MC-50) has been used for four years in neutron therapy and radioisotope production. Up to December 1989, 179(1852 sessions) patient have undergone neutron therapy. Radioisotope production for nuclear medicine use was started from March 1989 after extensive work to overcome target transport, target melting, beam diagnostic and chemical processing problems. This status report introduces the cyclotron facility, and the experiences of neutron therapy and isotope production with the MC-50 cyclotron. Besides, the operation results and the general troubles of the MC-50 during 1989 are summarized. Total operation time was 1252.5 hours. Four hundred hours were used for neutron therapy of 599 treatment sessions and 832.5 hours for radioisotope production. Total amount of produced raioisotope was 1695 mCi(Ga-67 : 1478mCi, Tl-201 : 107 mCi, I-123 : 25mCi, In-111 : 85mCi). Twenty hours were used for scheduled beam testing. In 1989, 882% of the planned operation were performed on schedule and this rats is improved remarkably compared to 71.0% in 1988.

  • PDF

The evaluation of image-guided catheter drainage in pleural effusion and empyema (흉수 및 농흉에서의 영상유도하 도관배액술의 유용성 평가)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.403-409
    • /
    • 1996
  • Background : Pleural fluid collections may pose a difficult therapeutic problem. Complete drainage of complicated effusions or empyemas and reexpansion of atelectatic lung are important in obtaining a satisfactory clinical outcome. The usual approach to the diagnosis and treatment of patients with pleural effusion and empyema has been with needle thoracentesis and chest tube drainage. With chest tube drainage, technical difficulties and failures may occur as a result of improper tube drainage, particularly when there is a loculation or multiple and inaccesible collections. Fluoroscopic or sonographic guidance facilitates the proper tube insertion and drainage. Method : Twenty eight patients were required for tube drainage due to pleural fluid collections between January 1994 to February 1996. The author compared the results of drainage under applying each different method between blind chest tube insertion and image guided catheter insertion. Results : The conventional blind chest tube group comprised 14 patients; 6 empyema, 6 tuberculous effusion, and 2 parapneumonic effusion. The image guided catheter group of smaller french were composed of 14 patients; 2 empyema, 6 tuberculous effusion, 5 parapneumonic effusion, and 1 effusion of undetermined origin. Radiologic improvement with successful drainage was noticed in 79% with the blind chest tube group, whereas in 93% with the image guided catheter group. The complication with the latter method was unremarkable. Conclusion : Image guided catheter drainage was safe and highly successful in treating patients, not only with complicated effusion also with loculated empyema. Image guided catheter drainage offers an alternative in patients in whom closed drainage is required as the initial treatment.

  • PDF

The High Cost of Fear (리포트 - 공포의 값비싼 대가)

  • Shellenberger, Michael
    • Nuclear industry
    • /
    • v.37 no.9
    • /
    • pp.58-90
    • /
    • 2017
  • '공포의 값비싼 대가(The High Cost of Fear)'는 공개된 자료 중 동료 평가를 마친 최신의 자료와 간단한 계산 방법을 통해 한국의 탈원전 정책이 가져올 경제적, 환경적 영향을 분석한 보고서이다. 우리는 탈원전 정책이 다음과 같은 영향을 미칠 것으로 예측한다. ${\cdot}$천연가스 구매에만 최소 매년 100억 달러의 비용이 들 것이다. 이는 한국 평균임금인 연소득 29,125달러를 받는 일자리 343,000개에 해당하는 금액이다. ${\cdot}$비용의 대부분은 연료 수입에 사용될 것이며, 한국의 무역 수지가 악화될 것이다. ${\cdot}$한국의 부족한 재생에너지 자원을 고려할 때, 상당한 양의 화석 연료를 추가로 사용하게 될 것이다. ${\cdot}$LNG 발전소가 석탄 발전소를 대체하지 못하고 원자력발전소를 대체하면서 대기 오염으로 인한 조기 사망자 수가 증가할 것이다. ${\cdot}$한국의 전도유망한 원전 수출 산업이 아예 붕괴되거나 큰 타격을 입을 것이다. ${\cdot}$평균적 미국 자동차의 연간 주행거리를 기준으로 150만대에서 270만대의 미국 자동차가 배출하는 배기가스의 양만큼 연간 탄소 배출이 증가할 것이고, 한국은 파리기후협정에서 약속한 탄소 배출 감축 목표를 달성할 수 없게 된다. 본 보고서는 현재 계획된 탈원전 정책의 역사적 사회적 배경을 분석하여 다음과 같은 결론을 도출하였다. ${\cdot}$'그린피스(Greenpeace)', '지구의 친구들(Friends for the Earth)' 등 막대한 자금 지원을 받는 해외 환경단체들은 탈원전 거짓 정보의 근원이며, 이들은 저렴하고 풍부한 에너지라는 개념을 반대한다. ${\cdot}$후쿠시마 원전 사고와 그 여파의 주된 원인은 일본 원자력산업계의 오만과 원자력에 대한 과장된 집단 공포이다. ${\cdot}$반핵 진영의 논리에는 산업계와 정부에 대한 불신과 원자력, 방사선에 대한 몰이해가 반영되어 있다. ${\cdot}$반핵 진영은 후쿠시마 사고를 2014년 한수원 납품 비리 사태의 심각성을 과장하는 데 사용하고 있다. 2014년의 비리 사태는 한국 원자력 규제기관의 독립성을 증명했으며, 2016년의 경주 지진은 2011년 후쿠시마에서 쓰나미와 노심 용융을 초래한 동일본 대지진의 1/350,000의 크기밖에 되지 않는다. 본 보고서는 한국과 타국가의 반핵 운동이 주는 교훈을 다음과 같이 정리하였다. ${\cdot}$어떠한 국가도 에너지 자원 최빈국인 프랑스나 한국 같은 국가조차도 탈원전 '전쟁'에서 자유롭지 않으며, 이는 전 세계적으로 원자력산업이 쇠퇴하는 원인이다. ${\cdot}$원자력산업계, 정부, IAEA 등은 한국과 세계 여러 국가에서- 문화적, 제도적, 재정적 원인으로 원자력산업의 보호와 확대라는 목표를 달성할 수 없다. ${\cdot}$원자력산업을 구하기 위해서는 새로운 비전과 새로운 제도, 그리고 새로운 리더십이 필요하다. ${\cdot}$원자력의 근원적이고 혁신적인 비전 원자력 인본주의(atomic humanism)에 대한 재조명이 필요하다. ${\cdot}$원자력을 지키고 대중과 소통하기 위해 과학 연구단체, 대학교, 사단법인, NGO 등의 새로운 기관들을 후원해야 한다. ${\cdot}$공포를 조장하는 반원전 세력에 맞서 공포를 극복해야 하고, 대중의 공포를 극복해왔던 다른 기술들의 사례에서 교훈을 얻어야 한다.

  • PDF

Hematologic Studies of Peripheral Blood and Bone Marrow in Miliary Tuberculosis (속립성결핵환자에서 말초혈액 및 골수의 혈액학적 소견에 대한 연구)

  • Jeong, Jae-Man;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.654-659
    • /
    • 1995
  • Background: Tuberculosis has commonly been associated with various hematologic changes. A difference between the changes found in pulmonary tuberculosis and those found in miliary tuberculosis has been discussed. Up to now some worker were investigated hematological changes associated with pulmonary tuberculosis but was not investigated those associated with miliary tuberculosis in korea. Therefore we examimed the peripheral blood and bone marrow findings in miliary tuberculosis patients to determine hematologic changes. Methods: We performed blood sample at admission and bone marrow biopsy within 7days after admission. For evaluation of the hematologic findings, full blood counts and marrow differential counts were defined by the criteria outlined by Dacie and Lewis. Results: 1) Peripheral blood findings: Pancytopenia in 10% of patients, anemia in all patients, leukocytosis in 10% of patients, leukopenia in 20% of patients, thrombocytopenia in 30% of patients, lymphocytopenia in 90% of patients, monocytosis in 40% of patients and neutrophilia in 10% of patients were found at peripheral blood. 2) Bone marrow findings: Lymphocytopenia in 30% of patients, lymphocytosis in 20% of patients, plasmacytosis in 40% of patients, monocytosis in 100% of patients, and hypocellularity in 30% of patients were found at bone marrow. Erythropoiesis was decreased in 30% of patients. Granulopoiesis was decreased in 20% of patients and increased in 20% of patients. Bone morrow granuloma occured in 25% of patients. Conclusion: Hematologic changes of miliary tuberculosis were seen tendency of cytopenic pattern but monocyte was increased at peripheral blood and bone morrow. This findings would provide additional information for the differential diagnosis of miliary tuberculosis.

  • PDF

Determination of Design Basis for a Storage System for Spent Fuel in Korea (국내 사용후핵연료 저장시스템의 설계기준 설정 인자 고찰)

  • Yoon, Jeong-Hyoun;Lee, Eun-Yong;Woo, Sang-In;Kim, Tae-Man
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • Safe operation and maintenance of engineered dry storage systems for spent fuel from nuclear power plants basically depends on adequately adopted design requirements. The most important design target of the system are those which provide the necessary assurances that spent fuel can be received, handled, stored and retrieved without undue risk to health and safety of workers and the public. To achieve these objectives, the design of the system incorporates features to remove spent fuel residual heat, to provide for radiation protection, and to maintain containment over the lifespan of the system as specified in the design specifications. The features also provide for all possible anticipated operational occurrences and design basis events in accordance with the design basis as guided by the designated regulations. The general performance requirements of a projected storage system are introduced in this paper. The storage system is designed to store fuel assemblies in associated with designated regulatory requirements. Small increases/decreases in maximum burnup can be adjusted with cooling time. These variations are compensated for by a corresponding small site-specific increase/decrease in the design basis-cooling period, as long as the maximum heat load and radioactivity of loaded fuel assemblies are met. Generic design basis events considered for the storage system are summarized. Shielding and radiological requirements along with mechanical and structural are derived in this study.

U.S. Policy and Current Practices for Blending Low-Level Radioactive Waste for Disposal (저준위 방사성폐기물의 혼합 관련 미국의 정책과 실제 적용)

  • Kessel, David S.;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.235-243
    • /
    • 2016
  • In the near future, many countries, including the Republic of Korea, will face a significant increase in low level radioactive waste (LLW) from nuclear power plant decommissioning. The purpose of this paper is to look at blending as a method for enhancing disposal options for low-level radioactive waste from the decommissioning of nuclear reactors. The 2007 U.S. Nuclear Regulatory Commission strategic assessment of the status of the U.S. LLW program identified the need to move to a risk-informed and performance-based regulatory approach for managing LLW. The strategic assessment identified blending waste of varying radionuclide concentrations as a potential means of enhancing options for LLW disposal. The NRC's position is that concentration averaging or blending can be performed in a way that does not diminish the overall safety of LLW disposal. The revised regulatory requirements for blending LLW are presented in the revised NRC Branch Technical Position for Concentration Averaging and Encapsulation (CA BTP 2015). The changes to the CA BTP that are the most significant for NPP operation, maintenance and decommissioning are reviewed in this paper and a potential application is identified for decommissioning waste in Korea. By far the largest volume of LLW from NPPs will come from decommissioning rather than operation. The large volumes in decommissioning present an opportunity for significant gains in disposal efficiency from blending and concentration averaging. The application of concentration averaging waste from a reactor bio-shield is also presented.

Ultrasound-Guided Injections in the Lumbar and Sacral Spine (요추 및 천추부에 대한 초음파 유도하 중재 시술)

  • Ko, Kwang Pyo;Song, Jae Hwang;Kim, Whoan Jeang;Kim, Sang Bum;Min, Young Ki
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.185-195
    • /
    • 2018
  • Study Design: Literature review. Objective: Ultrasound-guided injections are a common clinical treatment for lower lumbosacral pain that are usually performed before surgical treatment if conservative treatment fails. The aim of this article was to review ultrasound-guided injections in the lumbar and sacral spine. Summary of Literature Review: Ultrasound-guided injections, unlike conventional interventions using computed tomography or C-arm fluoroscopy, can be performed under simultaneous observation of muscles, ligaments, vessels, and nerves. Additionally, they have no radiation exposure and do not require a large space for the installation of equipment, so they are increasingly selected as an alternative method. Materials and Methods: We searched for and reviewed studies related to the use of ultrasound-guided injections in the lumbar and sacral spine. Results: In order to perform accurate ultrasound-guided injections, it is necessary to understand the patient's posture during the intervention, the relevant anatomy, and normal and abnormal ultrasonographic findings. Facet joint intra-articular injections, medial branch block, epidural block, selective nerve root block, and sacroiliac joint injections can be effectively performed under ultrasound guidance. Conclusions: Ultrasound-guided injections in the lumbar and sacral spine are an efficient method for treating lumbosacral pain.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Application of Incidence Angle on Lumbar Spine Anteroposterior General Radiography Image according to Measured Intervertebral Disc Angle (방사선 일반 정면검사에서 허리뼈 추간판 계측 값에 따른 입사각 적용)

  • Moon, Seul-Ji-A;Kim, Gyeong-Rip;Cho, Hee-Jung;Sung, Soon-Ki;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.6
    • /
    • pp.471-480
    • /
    • 2019
  • L-spine 3~4, L-spine 4~5, and L-spine 5~Sacrum 1 intervertebral disc(IVD) angle according to gender, age, body mass index(BMI), lumbar lordosis angle(LLA) were compared and analyzed. The anteriorposterior incidence angle of L-spine 3 ~ 4, L-spine 4 ~ 5 and L-spine 5~Sacrum 1 in body mass index were 5.66, 13.23 and 29.13 degrees in the head direction and L-spine 3 4, L-spine 4 ~ 5, L-spine 5~Sacrum 1 had 6.32 degrees, 16.09 degrees and 35.36 degrees in the head direction. The distortion area ratio comparison was performed with the phantom image using the proposed incidence angle. There was a significant difference in L-spine 4~5 and L-spine 5~Sacrum 1 IVD angle relative to body mass index and LLA(p<0.05), IVD angle and LLA were positively correlated(p<0.05).As a result of evaluating the usefulness of the image by applying the incidence angles of the disc angles according to the phantom angle of deviation to the head direction as 11 degrees for L4 and 26 degrees for L5, the distortion ratio area decreased from 14.90% to 12.11% in L4, And from 15.25% to 13.72% in L5. In anteriorposterior image of the Lumbar spine applying the incidence angle according to the measured disc angle, it is possible to reduce the distortion to purpose L4, L5. And improved the quality and diagnostic information of the target site.

Establishment of Integrated Design Bases Management System of APR1400 Using BIM based Algorithm (BIM기반 Algorithm을 활용한 APR1400 설계기준 통합관리 체계 구축)

  • Shin, Jaeseop;Choi, Jaepil
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.5
    • /
    • pp.52-60
    • /
    • 2019
  • The APR1400 is a 1400MWe nuclear power plant developed through national technology development project over a period about 10years. Approximately 65,000 design drawings are produced for APR1400 construction. In order to maintain consistency among numerous drawings, the highest level of design bases drawings (DBDs) are created according to design bases and this is used in the subsequent design. However, DBDs are produced and managed on a document basis and they are managed various field, it was difficult to accurately reflect the design bases information in the subsequent design. Therefore, this study recognizes limitations of the document based DBDs and develops a system that can accurately reflect the design bases information to subsequent design by adopting BIM based design bases integrated information system. Especially, by introducing DBIL(Design Bases Information Layer) concept, DBIL was created and analyzed based on five design bases(Physical protection, Fire protection, Internal missile protection, Internal flood protection, Radiation protection) applied to APR1400. In the final result DBIL set and Datasheet are integrated of room, design bases information, building data(wall, slab, door, window, penetrations). So it can be used for subsequent design automation and design verification. Furthermore, it is expected that APR1400 DBILs data can be used extensively in constructability and design economics analysis through comparison with next generation nuclear power plant.