• Title/Summary/Keyword: 방사선학적 정보

Search Result 128, Processing Time 0.025 seconds

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals (CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구)

  • Jeong, Cheon-Soo;Mo, Eun-Hee;Lee, Gee-Heun;Han, Beom-Hee;Kim, Seung-Chul;Kim, Jung-Sam;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.369-375
    • /
    • 2011
  • In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

A Radionuclides Suite Selection for Site Characterization and Final Status Survey in the U.S. NPPs (미국의 원전 해체관련 부지특성 및 최종상태 조사를 위한 방사성 오염 핵종 결정 방법에 대한 분석)

  • Zhao, Pengfei;Jeon, Yeo Ryeong;Kim, Yongmin;Lee, Jong Seh;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.267-277
    • /
    • 2016
  • For the decommissioning of a nuclear power plant, a site characterization and final status survey require a site-specific suite of radionuclides that could potentially still be present in the site during or after the decontamination processes. The United States Nuclear Regulatory Commission (U.S. NRC) requires a Decommissioning Technical Base Document (DTBD) along with a Site Characterization and Historical Site Assessment (HSA) from the utility for decommissioning to proceed. Both the DTBD and HSA are preliminary components of the Radiological Site Survey investigation process and should be included in the final License Termination Plan (LTP) for site release and reuse consideration from the U.S. NRC and the utility company. This study reviews the United States Nuclear Power Plants (U.S. NPPs) decommissioning cases and is especially focused on the methodologies used for determining a site-specific suite of radionuclides before and during the site characterization and final status surveys. In 2017, Kori-1 will be ready for decommissioning and related preparations are ongoing, this review will help Korea to prepare regulatory guidelines and give technical background for the safe and successful decommissioning of NPPs.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

Measurement of Space Dose Distribution during Exposure Micro Computed Tomography (μ-CT) for Scattering Rays (Micro-CT 촬영 시 발생되는 산란선에 관한 공간선량률 측정)

  • Jung, Hongmoon;Won, Doyeon;Kwon, Taegeon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Non-invasive technique CT, called automated computed tomography, is used to detect lesion of a patient when diagnosing human body. Information obtained from CT plays an important role in assembling 3 dimensional images. Recently, new equipment, operated by CT, is required which can be appliable to physical and biological research. In accordance to this quest, micro-CT is invented that produce more detail and concrete information. Images supplied by CT are even more detailed and concrete, so it contributes much to the development of biology and polymer material engineering field. However, there has been little reliable reports regarding measuring information of space dose distribution about exposure dose limit of users operating micro-CT. In addition, little reports regarding space dose distribution of exposure has been known about unwanted diffraction light produced by usage of micro-CT. The exterior of micro-CT is covered by lead, which is for removing exposure of diffraction light. Thus, even if it is good enough to prevent exposure of diffraction light, consistent management of equipment will be required as time goes by and equipment are getting old as well. We measured space dose distribution regarding exposure of diffraction light of users operating micro-CT directly. Therefore, we suggest that proper management should be necessary for users operating micro-CT not to be exposed by unwanted diffraction light.

A Study of the Internal and External Morphology in the Mandibular first Premolar of the Middle-Aged Korean Using a Microcomputed Tomography (미세단층촬영기를 이용한 중년 한국인 하악 제1소구치의 내 외부 형태학 연구)

  • Chun, K.J.;Lee, H.J.;Lee, Jong-Yeop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.254-261
    • /
    • 2005
  • Dental statistics for Koreans are far from complete and the majority of previous researches have adopted techniques such as radiological analysis and sectioning of teeth for morphological information, which are time-consuming, less accurate and destructive. Thus, a new nondestructive method is necessary to get precise dental standardization data for Koreans. For the above purpose, each of the first premolars was scanned by a micro-CT (SkyScan, Belgium) with a resolution of $21.31{\mu}m$ at an interval of 0.022mm along the plane horizontally parallel to an occlusion plane. Internal and external morphological sections were measured and compared to the values in the average tooth size table for permanent teeth presented by G. V Black.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

The Knowledge, Attitude and Behavior on the Radiation Safety Management for Dental Hygiene Major Students (치위생(학)과 학생의 방사선안전관리에 대한 지식, 태도 및 행위)

  • Jeon, Yeo Ryeong;Cho, Pyong Kon;Han, Eun Ok;Jang, Hyon Chul;Ko, Jong Kyung;Kim, Yong Min
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.411-420
    • /
    • 2015
  • Objectives : This study tries to find the educational basis based on the radiation safety knowledge, attitudes and behaviors to check the level of radiation safety behavior in domestic students who study dental hygiene. Methods : The students of 3rd and 4th grades in 83 universities which have registered on the Korean University Education Council were involved, and they were given a questionnaire for this study. The questionnaire was provided via visit with 20 copies to each university (total 1660 copies), mail by post and e-mail. Among them, we analyzed only 723 copies that we can trust. The data were analyzed with frequency, percentage, mean, standard deviation and Pearson's correlation using the SPSS/WIN 15.0. Results : As a result, there are correlations in the students' knowledge, attitudes and behaviors regarding the radiation safety management. It means that the education which can improve the knowledge and attitudes should be applied to increase the action level of the radiation safety. In addition, the physical environment is the most closely correlated with the individual behavior, so it will be limited to improve the behavioral levels of the radiation safety if the physical environment is not prepared. Therefore, the physical environment should be supported to enhance the level of the radiation safety activity, and to increase the individual attitude level of radiation safety. Conclusions : The knowledge level of the radiation safety management is relatively lower than the attitudes level, and the behavior level is the lowest. Therefore, the education policy of the safety behavior must be enhanced. For domestic students, the educational intervention is necessary to improve their behavioral level of radiation safety management because they will be able to reduce the amount of radiation exposure of their patients in dental care after getting a job.

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.

Grid Noise Removal in Computed Radiography Images Using the Combined Wavelet Packet-Fourier Method (CR영상에서 웨이블릿 패킷-푸리에 방법을 이용한 그리드 잡음 제거)

  • Lee, A Young;Kim, Dong Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.175-182
    • /
    • 2012
  • The scattered radiation always occurs when X-ray strikes the object. To absorb the scattered X-rays, the antiscatter grids are used, however these grids images are superimposed in the projection radiography images. When those images are displayed on the monitor, moir$\acute{e}$ patterns are overlapped over the images and disturb the anatomical informations. Most of the researches performed to date removed the grid noises by calculating or observing those frequencies in one dimensional frequency domain, two dimensional wavelet transform or Fourier transform. Those methods filtered not only the grid noises but also diagnostic informations. In this paper, we proposed the combined wavelet packet-Fourier method to remove the grid artifact in CR images. For the phantom image, the proposed method achieved from 5.2 to 7.4 dB better than others in SNR and for CR images by rejecting the grid noise bands effectively while leaving the remaining bands unchanged, the loss of images could get minimal results.