• Title/Summary/Keyword: 방사선피폭자

Search Result 213, Processing Time 0.023 seconds

Radiological Impact Assessment for the Domestic On-road Transportation of Radioactive Isotope Wastes (방사성동위원소 폐기물의 국내육상운반에 관한 방사선영향 평가)

  • Seo, Myunghwan;Hong, Sung-Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.279-287
    • /
    • 2016
  • Korea Radioactive Waste Agency (KORAD) began to operate the low and intermediate level radioactive waste disposal facility in Gyeongju and to transport the radioactive waste containing radioactive isotopes from Daejeon to the disposal facility for the first time at 2015. For this radioactive waste transportation, in this study, radiological impact assessment is carried out for workers and public. The dose rate to workers and public during the transportation is estimated with consideration of the transportation scenarios and is compared with the Korean regulatory limit. The sensitivity analysis is carried out by considering both the variation of release ratios of the radioactive isotopes from the waste and the variation of the distances between the radioactive waste drum and worker during loading and unloading of radioactive waste. As for all the transportation scenarios, radiological impacts for workers and public have met the regulatory limits.

공기정화필터 프레임 재사용과 그에 따른 효과 고찰

  • 윤철종;송대원;장동철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.194-195
    • /
    • 2005
  • 방사선관리구역 내에서 발생되는 많은 양(발전소별 연간 약$100{\sim}700$개 정도)의 사용 후 공기정화 필터는 고체 폐기물 드럼의 단면적 보다 넓어 별도로 필터를 압축하거나 분해 작업 없이는 폐기물로 직접 처리가 곤란하다. 처리 시 많은 양의 분진이 발생하여 작업자의 내부피폭 가능성 및 많은 양의 고체 폐기물이 발생할 수 있는 잠재성이 있어 시료분석 결과 오염된 필터 내지는 바로 드럼 처리하여 내부 피폭 가능성을 미연에 방지하고 필터 프레임은 재사용을 유도하여 폐기물 저감화, 작업환경 개선 및 경제적인 이익을 창출할 수 있다. 영광 3발전소와 울진 3발전소의 경우 타 발전소에 비해 방사선관리구역 내 공기정화 처리기의 설치수량이 많아(약 700개/년) 공기정화필터가 매년 다수 발생되고 있으며, 이를 전량 드럼 처리 시 고체폐기물 드럼이 더 발생하게 되어 영구처분비용의 증가를 초래하게 된다. 발전소 전체적으로는 약 3,500개/년의 폐필터가 발생되고 있다. 이렇게 발생되는 공기정화필터의 프레임을 재사용함으로써 그 효과는 1) 알루미늄을 포함한 유리섬유를 드럼처리 시 고체방사성 폐기물드럼 생성량 감소 2) 프레임 재사용으로 인한 예산절감 효과 3) 폐필터 분해작업 시 분진에 의한 작업자 체내${\cdot}$외 피폭방지와 작업장 오염 확산 방지 및 환경 개선 4) 작업시간 단축 및 소요인력 감소 효과를 볼 수 있다.

  • PDF

Use of Non-Parametric Statistical Method in Identifying Repetitive High Dose Jobs in a Nuclear Power Plant (비모수통계방법을 이용한 원자력발전소 작업자 반복성 고피폭작업 도출)

  • Young-Ho Cho;Young-Hoi Herr
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.41-51
    • /
    • 2004
  • The cost-effective reduction of occupational radiation dose (ORD) at a nuclear power plant could not be achieved without going through an extensive analysis of accumulated ORD data of existing plants. Through the data analysis, it is required to identify what are the jobs of repetitive high ORD at the nuclear power plant. In this study, Percentile Rank Sum Method (PRSM) is proposed to identify repetitive high ORD jobs, which is based on non-parametric statistical theory. As a case study, the method is applied to ORD data of maintenance and repair jobs at Kori units 3 and 4 that are pressurized water reactors with 950 MWe capacity and have been operated since 1986 and 1987, respectively in Korea. The results was verified and validated, and PRSM has been demonstrated to be an efficient method of analyzing the data.

  • PDF

해외 정보 - 프랑스의 원자력 시설 제염 해체 기술 개발 현황

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.36 no.7
    • /
    • pp.63-67
    • /
    • 2016
  • 프랑스는 원자력시설의 해체 과정에서 발생되는 방사성폐기물의 양을 최대한 줄이면서 그에 따른 비용과 작업자의 방사선 피폭을 최대한 줄일 수 있는 혁신적인 기술을 개발하고 있다. 이를 6개 분야로 나누어 소개한다.

  • PDF

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

An Optimization Study on the Radiation Management in Nuclear Power Plants (원자력 발전소 방사선 관리의 최적화에 관한 연구)

  • Song, Jong-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.71-82
    • /
    • 1993
  • It is a fundamental element of the nuclear power plant operation to assess exactly the occupational radiation exposure. And, according to recently published ICRP 60 recommendation, it is needed to reduce individual radiaton exposure limit further. In this paper, an optimization techique was suggested for selection of alternatives for reducing occupational radiation exposure, and used in reviewing alternatives given by a plant utility. After the basic analysis, sensitivity analysis was performed to consider the variabilities of the economic variables. From the result, it was found that an option using steam generator nozzle dam and torquing machine was the best with respect to total benefits, and in case of multi-attribute utility analysis, an option using Co-No seal had the highest utility. Therefore, it was necessary to apply more than one technique togeter in optimization study and to consider qualitative factor, too.

  • PDF

Numerical Calculations of IASCC Test Worker Exposure using Process Simulations (공정 시뮬레이션을 이용한 조사유기응력부식균열 시험 작업자 피폭량의 전산 해석에 관한 연구)

  • Chang, Kyu-Ho;Kim, Hae-Woong;Kim, Chang-Kyu;Park, Kwang-Soo;Kwak, Dae-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.803-811
    • /
    • 2021
  • In this study, the exposure amount of IASCC test worker was evaluated by applying the process simulation technology. Using DELMIA Version 5, a commercial process simulation code, IASCC test facility, hot cells, and workers were prepared, and IASCC test activities were implemented, and the cumulative exposure of workers passing through the dose-distributed space could be evaluated through user coding. In order to simulate behavior of workers, human manikins with a degree of freedom of 200 or more imitating the human musculoskeletal system were applied. In order to calculate the worker's exposure, the coordinates, start time, and retention period for each posture were extracted by accessing the sub-information of the human manikin task, and the cumulative exposure was calculated by multiplying the spatial dose value by the posture retention time. The spatial dose for the exposure evaluation was calculated using MCNP6 Version 1.0, and the calculated spatial dose was embedded into the process simulation domain. As a result of comparing and analyzing the results of exposure evaluation by process simulation and typical exposure evaluation, the annual exposure to daily test work in the regular entrance was predicted at similar levels, 0.388 mSv/year and 1.334 mSv/year, respectively. Exposure assessment was also performed on special tasks performed in areas with high spatial doses, and tasks with high exposure could be easily identified, and work improvement plans could be derived intuitively through human manikin posture and spatial dose visualization of the tasks.

Effective Dose Equivalent due to Inhalation of Indoor Radon-222 Daughters in Korea (한국인의 라돈-222 자핵종 호흡 실효선량당량 평가)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • Effective dose equivalents resulting from inhalation of indoor radon-222 daughters at 12 residential areas in Korea were assessed by a simple mathematical lung dosimetry model based on the measurements of long-term averaged radon concentrations at 340 dwellings. The long-term averaged indoor radon-222 concentrations and corresponding eqilibrium equivalent radon $concentration(EEC_{Rn})$ measured by passive time-integrating CR-39 radon cups are in the range of $33.82{\sim}61.42Bq/m^3(median\;:\;48.90Bq/m^3)$ and of $13.53{\sim}24.57Bq/m^3(median\;:\;19.55Bq/m^3)$, respectively. The effective dose equvalent conversion factor for the exposure to unit $EEC_{Rn}$ derived in this study was estimated $1.07{\times}10^{-5}mSv/Bq\;h\;m^{-3}$ for a reference adult and agreed well with those recommended by the ICRP and UNSCEAR. The annual average dose equivalent to the lung $(H_{LUNG})$ from inhalation exposure to measured $EEC_{Rn}$ was estimated to be 20.90 mSv and resulting effective dose $equivalent(H_E)$ was to be 1.25 mSv, which is about 50% of the natural radiation exposure of 2.40 mSv/y to the public reported by the UNSCEAR.

  • PDF

Validation of a Real-Time Dose Assessment System over Complex Terrain (복잡한 지형상에서 실시간 피폭해석 시스템 검증)

  • Suh, Kyung-Suk;Kim, Eun-Han;Hwang, Won-Tae;Choi, Young-Gil;Han, Moon-Hee;Jung, Sung-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 1999
  • A real-time dose assessment system(FADAS : Following Accident Dose Assessment System) has been developed for the real-time accident consequence assessment against a nuclear accident. Field tracer experiment near Younggwang nuclear power plant was performed to improve the accuracy of developed system and to parameterize the site-specific parameters into the FADAS. The mean values and turbulent components of wind profile obtained through field experiment have been reflected to FADAS with site-specific conditions. The simulated results of diffusion model agreed well with the measured data through tracer experiment. The developed system is being used as a basic module of emergency preparedness system in Korea. The diffusion model which can be reflected site-specific parameters will be improved through field experiments continuously.

  • PDF