• Title/Summary/Keyword: 방사선측정기

Search Result 137, Processing Time 0.028 seconds

The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택)

  • Kim, Jung-Min;Im, Eun-Kyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.273-277
    • /
    • 2005
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared image quality and radiation dose of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of $60{\sim}150kVp$. Published data on the effect of x-ray beam energy on image quality and patient dose when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

The development of tube voltage meter using the semiconductor (반도체소자를 이용한 관전압계의 개발)

  • Seon, Jong-Ryul;Shin, Dae-Chul
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.71-75
    • /
    • 2002
  • According to this study, we can make the radiation check meter which have not supply because of high cost and import barrier and lengthen its life by means of repairing of radiation bomb and equipment. We can make better medical service. In my study, I used the photodiod, photoelectron, among semiconductor detectors which have a excellent detect capacity and are low cost and small size. I set up this equipment in June 1, 2002, used 640 mA remote operative fluorography equipment, which make the grade as capacity test. I used the standard measuring instrument which took proofs from a agency, now it was using in measuring agency. The comparative measuring instrument used in same condition. I took the standard which was gauged with a connecting measuring instrument. Using a existing unconnected measuring instrument, I compared the accuracy with new unconnected one. As a result, three score are within the standard. For the detailed analysis, I took the average of percentage average error. So standard instrument was -0.02, comparable was -0.22, and new one was -0.17. New one took a closer measured value with standard than comparable one. In more study, I think to take more accurate value. I expect that my study will be a base of measuring instrument, with low cost, supply of this instrument increase, I expect to decrease radiation bomb and maintain, repair and manager better.

  • PDF

The development of a high level radiation detector for reactor inspection robot (원자로 검사 로봇용 고준위 방사선 측정기 구현)

  • Lee, Nam-Ho;Cho, Jai-Wan;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.278-280
    • /
    • 2005
  • 원자력발전소 내 원자로의 유지보수 작업을 수행하는 수중로봇은 고준위 방사선에 노출되고, 이로 인해 전자 장치의 오동작 및 고장이 유발될 수 있다. 따라서 허용 방사선량을 초과하지 않도록 피폭되는 누적 방사선량을 실시간으로 모니터링하는 장치가 필수적이다. 본 연구에서는 펄스형의 SiC 포토 다이오드와 선량 기억형인 MOSFET를 다중 방사선 센서로 사용하여 넘은 범위의 방사선 준위의 측정이 가능하고 측정 신뢰도가 향상된 고준위 방사선 측정기를 구현하였다. 이 장치는 측정 원리가 상이한 두 센서를 동일한 방사선 측정에 이용함으로써 방사선 측정의 안정성과 정확성이 향상된 것이 특징이다.

  • PDF

High Energy Photon Dosimetry by ESR Spectroscopy in Radiotherapy (ESR Spectroscopy에 의한 치료용 고에너지 광자선의 선량측정)

  • Chu, Sung-Sil
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • The finding of long lived free radicals produced by ionizing radiation in organic crystals and the quantification of this effect by electron spin resonance(ESR) spactroscopy has proven excellent dosimetric applicability. The tissue equivalent alanine dosimeter also appear appropriate for radiation therapy level dosimetry. The dose measurement was performed in a Rando phantom using high energy photons as produced by high energy medical linear accelerator and cobalt-60 teletherapy unit. The absorbed dose range of the ESR/alanine dosimetry system could be extended down to 0.1 Gy. The response of the alanine dosimeters was determined for photons at different therapeutic dose levels from less than 0.1 Gy to 100 Gy and the depth dose measurements were carried out for photon energies of 1.25MeV, 6 and 10 MV with alanine dosimeters in Rando phantom. Comparisons between ESR/alanine in a Rando phantom and ion chamber in a water phantom were made performing depth dose measurements to examine the agreement of both methods under field conditions.

  • PDF