• Title/Summary/Keyword: 방사선조사효과

Search Result 881, Processing Time 0.028 seconds

A Study on the Development of High-sensitivity AEC-sensor for Minimization of Dose Creep in Diagnostic Imaging System (진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구)

  • Kim, Kyo-Tae;Han, Moo-Jae;Heo, Ye-Ji;Kim, Joo-Hee;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.321-325
    • /
    • 2016
  • Dose creep is one of clinical errors that arises from the tester's inexperience or carelessness, and according to Task Group #116 of American Association of Physicists in Medicine, its continued occurrence is being reported in the digital method. At this point, the demand for an automatic exposure control device that minimizes the dose creep phenomenon and can improve reproducibility is increasing. In this study is to consider the automatic exposure control device sensor that can is not only easy to produce, but also reduce the dose creep phenomenon by conducting a research on high-efficient semiconductor sensor. As a result, the Intrinsic-type and PIN-type sensors have excellent optical property compared to Ref sensor, would have less shading effect, and have relatively low sensitivity, but would provide accurate feedback signals to automatic exposure control device with its consistent tendency according to exposure condition changes.

Effects of Gamma-Ray and Heat Treatment on Sterilization of Escherichia coli O157:H7 (Escherichia coli O157:H7의 살균을 위한 감마선과 가열처리의 효과)

  • Kwon, Oh-Jin;Yook, Hong-Sun;Kim, Seong-Ai;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.1016-1020
    • /
    • 1997
  • Treatments of irradiation alone and/or in combination with heat were investigated for the sterilization of Escherichia coli O157: H7. D values of the strain were 129.2 min at $50^{\circ}C$, 27.1 min at $55^{\circ}C$, and 2.4 min at $60^{\circ}C$. The survival effect of E. coli O157:H7 during heating at various media was investigated. On heating at temperature of $60^{\circ}C$ for 10 min, the strain was generally more resistant in the media containg such chemical substrates such as 0.03 M cysteine, 1% sodium citrate or 5% sucrose, whereas this strain was appeared weaker in the chemical substrates added group such as 1% meat extract, 1% casein or 1% casamino acid. In the case of irradiation alone, $D_{10}$ value of E. coli O157:H7 was 0.116 kGy, and inactivation factors were $17{\sim}25$ at doses of 2 to 3 kGy. Pre-and post-irradiation heating showed the same $D_{10}$ value about 0.07 kGy. And Inactivation factors were $25{\sim}41$ at doses of 2 to 3 kGy. Therefore, combination treatment with heat and irradiation significantly increased in inactivation rate by increasing radiation sensitivity of E. coli O157:H7.

  • PDF

Influence of Diode Laser (808 nm) on a Rat Anterior Cruciate Ligament Transection Model of Osteoarthritis (전십자인대 단열을 통한 랫드 골관절염모델에서 다이오드레이져 (808 nm)의 영향)

  • Park, Seongkyu;Minar, Maruf;Hwang, Yawon;Kim, Somin;Park, Minhyeok;Choi, Seok-Hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.346-352
    • /
    • 2013
  • The study was aimed to investigate the influence of diode laser on osteoarthritis (OA) of stifle joint induced by anterior cruciate ligament transection (ACLT). Sixty 10-week-old male Sprague-Dawley rats were used in this study. Right stifle joint was operated to create ACLT or sham. There were five study groups: control, Sham, ACLT, ACLT + Laser irradiation (ACLT+L) and ACLT + meloxicam administration (ACLT+M). Low-level laser therapy (LLLT) was applied at the operated stifle joint twice a week using an 808-nm indium-gallium-arsenide (InGaAs) diode laser during 8-week experimental period. Radiographical, gross morphological and histopathological findings were examined at 2, 4 and 8 weeks post-surgery. Radiography, CBC and chemistry tests showed no significant difference between groups. ACLT+L group showed remarkable cartilage damages compared with sham group morphologically and histopathologically at 2, 4 and 8 weeks after surgery. ACLT+M group also had more cartilage damages compared with sham group. Low-level laser therapy (LLLT) showed limitation to prevent progression of OA in the rat anterior cruciate ligament transection models; on the contrary it accelerated cartilage damage. It is assumed that the aggravating results of LLLT in this study might be due to excessive unstable movement of stifle joint from the pain-relieving effect of LLLT, rather than direct damaging effect of irradiation since LLLT did not affect cell viability.

The Head Scatter Factor For Quasi - small Field Sizes (준소조사면에서의 산란인자)

  • 이상공;김진기;김정홍;김부길;권형철;김정수
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.13-19
    • /
    • 1995
  • The behavior of the correction factor associated with the collimator opening(head-scatter factor) were investigated for the 6MV x-ray beams of medical linear accelerator. The primary photon fluence was measured in air quasi-small fied size. Consideration in this study was given to the effect of head scatter factor with quasi-small fied size, the upper and lower collimator jaw scatter collection factors of quasi-small field (4-10cm) were measured with ion chamber. In general, the wedge factors which are used clinical practics are ignored of dependency on field sizes and depth. In wedge factors for each wedge filter were measured at various depth by using 6MV X-ray. In this present we inverstigated systematically the depth and field sizes dependency to determine the absorbed dose more accurately. Head scatter(upper-lower collimator jaw)appears to be (1) a small effect, less than 5% over the range of clinical field sizes (2) generated primarily at the flattening filter and therefored influenced most by the upper collimator setting.

  • PDF

Radiation Preservation of Fishery Products. II. Application of Radiation Preservation to Cure Shrimp, Common Squid and Little Squid

  • Sang Choe;Chung, Tai-Wha;Kwak, Hi-Sang
    • Nuclear Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.23-31
    • /
    • 1969
  • Whole cure shrimp, eviscerated common squid and little squid meats were irradiated with gamma radiation from 60Co using varying dose up to one Mrad. Changes in quality were assessed by organoleptic, chemical (VRS and TMA-N), biochemical (hypoxanthine) and microbiological tests; and the effect of radiation on prolonging of the storage life at 2-4 C was studied. With the cure shrimp, 0.12-0.20 Mrad appears to be optimal with 8 days of storage life, whereas the unirradiated control samples had a storage life of 3 days. With the common squid meat, 0.20-0.30 Mrad appears to be optimal with 14-21 days of storage life, where-as the unirradiated control samples had a storage life of 8 days. And for the little squid meat, 0.12-0.20 Mrad appears to be optimal with 10 days of storage, where-as the unirradiated control samples had a storage life of 5 to 6 days.

  • PDF

Changes in the Antigenicity of Chicken Egg White by the Treatments of Protease, Trifluoromethanesulfonic Acid, Heat, and NaOH (효소, Trifluoromethanesulfonic Acid, 열, 및 NaOH 처리에 의한 계란 난백의 항원성 변화)

  • Ryu, Ju-Hyune;Lee, Jong-Mee;Shon, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.720-725
    • /
    • 2000
  • To reduce the antigenicity of egg white (EW), EW was treated with several proteolytic enzymes, trifluoromethanesulfonic acid (TFMS), heat, and NaOH. Competitive indirect enzyme-linked immunosorbent assay (ciELISA), using rabbit anti-EW antibody, was performed to examine the antigenicity of the treated EW's. Enzymatic hydrolysis gave no good effect on the reduction of the antigenicity of EW. Neither did the pretreatment with ${\gamma}-irradiation$ before the hydrolysis reduce the antigenicity. TFMS treatment removed the antigenicity of EW. The antigenicity of EW heated at $120^{\circ}C$ for 30 min or treated with NaOH at 0.3% (w/v) and more, decreased to less than 1/10,000 as compared with that of native EW. The combinatory treatment with NaOH, followed by heat at $70^{\circ}C$ for 15 min had a synergic effect on the reduction of the antigenicity of EW.

  • PDF

Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system (시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.141-146
    • /
    • 2001
  • It is well known that assurance of the radiation therapy needs for an accuracy of $\pm$ 5 % in the delivery of an absorbed dose to target volume. Therefore, the dose evaluation of brachytherapy source and/or linear accelerate beam must be a stability with accuracy. In an advanced country, they recommended to use the radioactive check source for reference air ionization chamber for a stable response of radiation field chamber. In this experiments, the radioactive source Sr-90 and PR-05 air ionization chamber were used for standard source and reference ion chamber. The response of reference ion chamber showed as an 1.000$\pm$ 0.010 uncertainty for 10 years long and the evaliuation f dose discrepancy of clinical field ion chamber showed as 0.997 $\pm$0.011 in a $^{60}$ Co brachytherapy soruce. In our experiments, we can assuarance the long halflife standard source is reliable to preserve the calibration factor of reference chamber in stability.

  • PDF

Radiation-Induced Grafting of Acrylic Acid onto Cellulose : I. Graft Polymerization of Acrylic Acid onto Radiation-Peroxidized Cellulose (셀롤로오스에 아크릴산의 방사선 그라프트 반응: I. 과산화물에 의한 그라프트반응)

  • Kwon, Oh Hyun;Nho, Young Chang;Yang, Hyun Soo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.934-938
    • /
    • 1997
  • Acrylic acid was grafted onto the peroxidized cellulose which was stored at room temperature for 20 days after ${\gamma}$-ray irradiation in air. The effect of acids and metallic salts on the grafting yields was determined. The addition of both the acid and metallic salt was found to accelerate the grafting yield much more than the only metallic salt, and the addition of $FeSO_4{\cdot}7H_2O$ led to much higher grafting yield than that of $CuSO_4{\cdot}5H_2O$. The effect of acid on the grafting yield increased by the order $H_2>SO_4>HCl>HNO_3>CH_3COOH$. With the addition of $H_2SO_4$, the grafting yield rapidly increased up to $7{\times}10^{-2}$M, and then levelled off.

  • PDF

Ecdysteroid Titer during Metamorphosis and the Effect of Ecdysteroid on Oocyte Develoment on Phormia regina (검정금파리의 변태기에 따른 엑디스테로이드와 난세포성숙에 미치는 엑디스테로이드의 효과)

  • 이종진
    • Korean journal of applied entomology
    • /
    • v.31 no.4
    • /
    • pp.371-378
    • /
    • 1992
  • The ecdysteroid titers of representive developmental stages of the blackblow fly, Phormia regina, were determined by radioimmunoassay and the effect of ecdysteroid on the oocyte maturation was investigated. Prior to every molts ecdysteroid levels began to increase sharply, suggesting ecdysteroid was the major component for egg-larval, larval-larval, and larval-pupal transformation. A difference in the levels of ecdysteroid between male and female was ob¬served during adult life span. Following the protein meal, ecdysteroid in the females increased rapidly to a maximum at 96 hr of age when terminal oocyte fully matured. Effect of ecdysteroid on oocyte development was determined for control and ecdysone-treated female flies after the liver-feeding. The growth of oocyte in the flies treated by $\mu$g of ecdysone, along with the control flies, was not facilitated. When the flies treated by 5 $\mu$g of ecdysone, however, duration of oocyte maturation was shorter than those of other two groups. This can be suggested that oocyte development in P. regina is due to the critical level of ecdysone.

  • PDF

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF