• Title/Summary/Keyword: 방사선조사효과

Search Result 882, Processing Time 0.026 seconds

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Dosimetric and clinical review on the application of TOMO_edge mode (토모테라피 Edge 모드를 이용한 임상적 유용성 고찰)

  • Kim, Lizzy
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.177-182
    • /
    • 2014
  • Purpose : The goal of this study was to compare and analysis the dose distribution and treatment time between Tomotherapy planning with fixed jaw(FJ) and dynamic jaw(DJ). Materials and Methods : Seven patients were selected in the study including five common clinical cases(brain, head and neck(HN), lung, prostate, spine). 1) Helical Tomotherapy plans with FJ and DJ were generated with the same planning parameters such as Modulation factor, Pitch and Field width. 2) Tomo_edge plans with a larger field width were generated to compare to conventional HT delivery with fixed jaw. Dosimetric evaluation indices for target coverage are Dmin, Conformity index(CI) and for whole body including target are $V_{10%}$, $V_{25%}$, $V_{50%}$, $V_{75%}$ using Dose-volume histogram(DVH). Also, Treatment time and Cumulative MU were used for clinical review on Tomo_edge. Results : In case of using the same field width of Tomotherapy planning with FJ and DJ, the averaged variations were $V_{10%}$: -11.91%, $V_{25%}$: -7.6%, $V_{50%}$ :-4.75%, $V_{75%}$: -1.04%. Tomo_edge with a larger field width provides the averaged variations for target coverage: Dmin: -0.72%, CI: -1.25% and also shows the tendency of a sharp $V_{x%}$ decline in low dose area. The clinical improvements in the larger field width with DJ were observed in the treatment time, ranging from -51.21% to -15.11, and the Cumulative MU decrease, ranging from -57.74% to -15.31%. Conclusion : Target coverage achieved by FJ and DJ with the same field width has little differences. But integral doses on whole body efficiently decreased. Compared to the conventional HT delivery, Tomo_edge with a larger field width presents a little worse target coverage. However, it provides faster treatment delivery and improved cranial-caudal target dose conformity. Therefore, Tomo_edge mode is efficient in improving the treatment time and integral dose while maintaining comparable plan quality in clinic.

A Study of x-ray tube voltage, tube current and dose rate depeding on temperature (온도 변화에 따른 X-선진단장치의 관전압, 관전류, 조사선량에 관한 연구)

  • Chon, Ki-Hwan;Hwang, Min-Seon;Choi, Myeon-Woong;Lee, Song-Yi;Kim, Min-Ji;Yang, Dong-Il;Lee, Gwi-Yeol
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.264-272
    • /
    • 2011
  • This study was function experiment or inspection of diagnosis x-ray unit at the hospital. It's how many changes tube voltage, tube current, DOSE value through the experiment depending on temperature increasing. The study want to know whether which parameter shown out of range or not how about image quality and so on. Increasing tube current and DOSE were not only too many radiation to the patient and radiation workers and make bad images but also the tube should be damaged by heat. This study was recommended proper exposure at intervals of seconds because passed inspection, reduced radiations for patient and the tube used long term. This results in the hospital`s finances will be very helpful.

Elimination of Microorganisms Contaminated in Red Ginseng Powder by Irradiation Processing (감마선 조사를 이용한 홍삼분말의 오염미생물 제거)

  • Yook, Hong-Sun;Kim, Seong-Ai;Byun, Myung-Woo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.366-370
    • /
    • 1996
  • Gamma irradiation was applied to red ginseng powder for improving its hygienic quality 7.5 kGy of gamma irradiation completely eliminated the microorganisms contaminated in red ginseng powder. And there was no growth of microorganisms after six months of storage at room temperature. The molds isolated from red ginseng powder were identified as Pen. commune, Asp. niger, Asp. versicolor and Asp. Unguis, the conidia of which showed the decimal reduction dose ($D_{10}$ value) of 0.37-0.50 kGy, 0.24-0.31 kGy, 0.25-0.36 kGy and 0.28-0.41 kGy and inactivation factor of 5.0-6.5, 7.4-9.3, 6.5-9.1 and 6.1-8.4, respectively The radiosensitivity of identified molds' conidia decreased in medium containing red ginseng extract.

  • PDF

Studies on the Shelf-life Extension of Jeotkal, Salted and Fermented Seafood (젓갈류의 유통기한 연장을 위한 연구)

  • Cho, Hak-Rae;Park, Uk-Yeon;Chang, Dong-Suck
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.652-660
    • /
    • 2002
  • To develop natural food preservatives for extending the shelf-life of jeotkal (salted and fermented seafood), antimicrobial substances were extracted from 32 types of medicinal herbs and edible plants using 95% ethanol. Among the extracts, Glycyrrhizae radix, Curcumae domestica, Galla rhois, and Resina pini showed relatively high inhibitory effects on the growth of the microorganisms isolated from the deteriorated jeotkal. We selected and tested the extract from Recina pini as a natural jeotkal preservative. This ethanol extract was purified partially by adding equal quantity of water, through which 77% of insoluble materials were removed as impurities. In manufacturing modified jeotkal using squid, sucrose and starch syrup were substituted with sorbitol, $glucono-{\delta}-lactone$ was added instead of vitamin C and lactic acid, and sterilized hot pepper was used instead of natural one. The shelf-life of modified jeotkal was prolonged by 4 days compared with the control jeotkal when stored at $20^{\circ}C$, while that of modified jeotkal containing 1.0% partially purified Recina pini extract was prolonged by 6 days compared to the control. The same tests were conducted for the changran (stomach and intestine of Alaska pollack) jeotkal preservation. The shelf-life of the control jeotkal was 24 days, whereas the modified jeotkal and the Resina pini extract-containing modified jeotkal maintained their qualities without changes in microbial and chemical characteristics for 90 days at $20^{\circ}C$ storage.

Facemask Effects in Two Types of Intraoral Appliances : Bonded Expander vs. Hyrax (구내 장치 종류에 따른 facemask의 효과 비교 : bonded expander와 Hyrax)

  • Park, Chanyoung;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • The purpose of this study was to compare and evaluate facemask effects when two types of intraoral appliances were used for maxillary protraction for patients with class III malocclusion. Eighteen patients with class III malocclusion were treated with a facemask for an average of 12 months. Two types of intraoral appliances were used: nine patients were treated with bonded expander (Group 1), and nine patients with Hyrax (Group 2). Cephalometric radiographs were taken before and after treatment. Cephalometric radiographs were traced, analyzed, and the results such as sagittal, vertical and soft-tissue changes were compared between two groups. The amount of anchorage loss was also measured to evaluate the difference between two groups. All patients showed significant sagittal skeletal changes after treatment, and there was no statistically significant difference between the two groups. When anchorage loss was evaluated, no differences were shown between the two. Facemask with Hyrax or bonded expander is similarly an effective method as a treatment in class III malocclusion patients.

Cell Death of Human Promyelocytic Leukemia Cell after Low Dose of Electron Beam Irradiation with TNF-α (저 농도의 전자선을 조사한 전골수구성 백혈병 세포 죽음에서의 TNF-α 작용 효과)

  • Kim, Dong Hyun;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.241-246
    • /
    • 2014
  • Acute promyelocytic leukemia (APL) is a cancer of the blood. Although electron beam (EB) irradiation is used with other anti-cancer agents, EB irradiation can be harmful to normal tissues around the cancer. In the present study, we evaluate the differential cytotoxic effect of EB irradiation with other molecules, including TNF-${\alpha}$, on DMSO-treated HL-60 cells and HL-60 cells. HL-60 cells are the human promyleocytic leukemia cell line and are differentiated by DMSO. DMSO-treated HL-60 cells are considered to be normal granulocytic cells. In these results, TNF-${\alpha}$ may be used as the potential agent for the treatment of blood cancer without side effects in low dose of EB irradiation therapy.

TID and SEGR Testing on MOSFET of DC/DC Power Buck Converter (DC/DC 강압컨버터용 MOSFET의 TID 및 SEGR 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.981-987
    • /
    • 2014
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a MOSFET (metal-oxide semiconductor field effect transistor), a PWM-IC (pulse width modulation-integrated circuit) controller, inductor, capacitor, etc. It is shown that the variation of threshold voltage and the breakdown voltage in the electrical characteristics of MOSFET occurs by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 5 heavy ions make the gate of MOSFET broken in SEGR (Single Event Gate Rupture) testing. TID testing on MOSFET is accomplished up to the total dose of 40 krad, and the cross section($cm^2$) versus LET(MeV/mg/$cm^2$) in the MOSFET operation is studied at SEGR testing after implementation of the controller board.

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.

The compensatory adaptation of anterior teeth according to the skeletal relation (악골관계에 따른 전치부교합의 보상적 적응에 관한 연구)

  • Oh, Chang-Keun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.175-183
    • /
    • 2000
  • The purpose of this study was to identify the compensatory adaptation of dentoalveolar structure according to the various skeletal relation through the statistical correlation between the anteroposterior, vertical skeletal and dentoalveolar relation. For this study, the sample were consisted of 101 adult subjects (51male and 50 female, mean age; male 23.6 years, female 21.5 years) who had good occlusion with the range of normal overjet and overbite and acceptable Angle's class I molar relationship which had not been related orthodontically The results were as follows : 1. Even though acceptable normal occlusion, the range of measurements which represent anteroposterior, vertical skeletal relation and dentoalveolar relation were very wide. 2. Upper and lower incisor axis were significantly correlated with anteroposterior skeletal relation, which means the mote lingual inclination of upper anterior teeth and the more labial inclination of lower anterior teeth according to the more anterior position of mandible to the maxilla (P<0.01). 3. Upper and 1ower anterior alveolar bone height was statistically correlated with the lower anterior vertical skeletal height. 4. Upper and 1ower alveolar bone height were not correlated with anteroposterior skeletal relation (P>0.05). 5. The correlation between the incisor axis and vertical skeletal was more closely related in upper anterior teeth than the lower anterior teeth. To summarize the above results, even though acceptable normal occlusion, skeletal and dentoalveolar relation was very widely ranged, and there were close relationship between the anteroposterior skeletal relation and the inclination of upper and lower anterior teeth and between the vertical skeletal relation and upper and lower anterior alveolar bone height. These finding can be concluded as compensatory adaptation to the different skeletal relationship.

  • PDF