• Title/Summary/Keyword: 방사선오염

Search Result 321, Processing Time 0.028 seconds

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

Radiology Department Infection Control According to Radiography Frequency and Disinfection Period (촬영 빈도수 및 소독 주기에 따른 영상의학과 감염 관리)

  • Lee, Jae-Seung;Jeong, Kyu-Hwan;Kim, Gyoung-Hee;Im, In-Chul;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines. The ATP Public Heath Monitering System was used to measure seven items for pollution levels of imaging equipment and assistive apparatuses in the Radiology Department. Data was analysed using SPSS version 12.0 for paired t-test and Pearson coefficient with a statistically significant level of 0.05. The results of the survey showed a total awareness level of infection management prevention education averaged at $3.73{\pm}0.64$ and performance levels resulted at $3.39{\pm}0.83$ which were statistically significant (p = 0.01). Also the measurements of pollution levels for equipment with high patient contact showed a Pearson Coefficient of over 0.5 implying a focus on pathogenic bacterium. There was no statistical significance with the frequency of imaging (p < 0.05). Therefore for general hospitals with high patient contact, there is a need to supply analyzing equipment for real time monitoring and the implementation of disinfection management that uses a Ministry of Health and Welfare approved antiseptic solution twice every minute.

Comparison of Ethylene Oxide (E.O.) and Irradiation Treatment on the Sterilization of Spices (향신료(香辛料)의 Ethylene Oxide 처리(處理)와 감마선(線) 조사(照射)와의 살균효과 비교)

  • Cho, Han-Ok;Byun, Myung-Woo;Kwon, Joong-Ho;Lee, Jae-Won;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.283-287
    • /
    • 1986
  • E.O. and gamma irradiation treatment on the sterilization of ground samples of 5 different types of spices(red and black pepper, onion, garlic and ginger) were investigated. Populations of mesophilic bacteria, mesophilic spores, acid tolerant bacteria and fungi in various samples were $10^4-10^6/g,\;10^3-10^5/g,\;10^3-10^5/g\;and\;10^3-10^4/g$, respectively. Coliforms and osmophilic molds were found only in red and black pepper as $10^3-10^4/g$. A radiation dose of 5 to 7 kGy proved sufficient to redure the viable cell count of the total bacteria and fungi to the level of $10^3/g$ and they were sterilized completely by radiation dose of 10 kGy or more. Coliforms, mesophilic spores and acid tolerant bacteria were sterilized at 5,7 and 10 kGy, respectively. In the mean time $D_{10}$ values of each spices ranged from 1.38 to 2.88 kGy. Comparison of E.O. and gamma irradiation treatment showed that E.O. treatment was less effective than radiation in controlling microbial contamination in spices.

  • PDF

Monte-Carlo Simulations of Non-ergodic Solute Transport from Line Sources in Isotropic Mildly Heterogeneous Aquifers (불균질 등방 대수층 내 선형오염원으로부터 기원된 비에르고딕 용질 이동에 관한 몬테카를로 시뮬레이션)

  • Seo Byong-min
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.20-31
    • /
    • 2005
  • Three dimensional Monte-Carlo simulations of non-ergodic transport of a lion-reactive solute plume by steady-state groundwater flow under a uniform mean velocity in isotropic heterogeneous aquifers were conducted. The log-normally distributed hydraulic conductivity, K(x), is modeled as a random field. Significant efforts are made to reduce tile simulation uncertainties. Ensemble averages of the second spatial moments of the plume and plume centroid variances were simulated with 1600 Monte Carlo runs for three variances of log K, ${\sigma}_Y^2=0.09,\;0.23$, and 0.46, and three dimensionless lengths of line plume sources normal to the mean velocity. The simulated second spatial moment and the plume centroid variance in longitudinal direction fit well to the first order theoretical results while the simulated transverse moments are generally larger than the first order results. The first order theoretical results significantly underestimated the simulated dimensionless transverse moments for the aquifers of large ${\sigma}_Y^2$ and large dimensionless time. The ergodic condition for the second spatial moments is far from reaching in all cases simulated, and transport In transverse directions may reach ergodic condition much slower than that in longitudinal direction. The evolution of the contaminant transported in a heterogeneous aquifer is not affected by the shape of the initial plume but affected mainly by the degree of the heterogeneity and the size of the initial plume.

An Experimental Study on Internal Decontamination Radiocobalt (Radiocobalt의 체내 오염(汚染)에 대(對)한 제염효과(除染效果))

  • Chung, In-Yong;Kim, Tae-Hwan;Chung, Hyun-Woo;Chin, Soo-Yil;Yun, Taik-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.1
    • /
    • pp.31-41
    • /
    • 1988
  • In case of the acute intake of radionuclide, an early medical treatment may be necessary, but the little is established the procedures to decontaminate the victims of internal contamination in Korea. The purpose of the present investigation is to study chemical agents to remove radiocobalt from the victims and to provide a more reliable procedure for the treatment. The removals of radiocobalt from the NIH-CGP)mice injected intraperitoneally with $1{\mu}Ci$ of $^{58}Co$ as $CoCl_2$ were investigated with doses of either $CaNa_3$ DTPA 8.4mg/0.2ml saline, $CoNa_3$ DTPA 8.4mg/0.2ml saline, or saline 5ml. The radioactivity was determined by MCA and Ge-detector on 4, 8, 12, 48 hours and 7 days for the whole body, organ distribution and urine excretion. Six mice per each group were sacrificed for the measurement of cobalt retention in the parenchymal tissue. The cobalt trisodium chelate had a pronounced effect on reducing the whole body retention and increasing the excretion rate. Regarding to the systemic protective effects, $CoNa_3$ DTPA, $CaNa_3$ DTPA and saline were effected significantly in order. In conclusion, the extrapolations from these results to human were suggested that the rapid administration of cobalt trisodium chelate and an amount of saline to the contaminated person after internal contamination of radiocobalt were markedly increasing the decontamination effects.

  • PDF

A Case of Chemical Pneumonitis Caused by Nitric Acid Fume Inhalation (질산(Nitric Acid) 증기 흡입에 의해 발생한 화학성 폐렴 1예)

  • Ha, Jun-Wook;Lee, Seung Soon;Eom, Kwang-Seok;Bahn, Joon-Woo;Jang, Seung Hun;Kim, Dong Gyu;Lee, In Jae;Lee, Yul;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.670-676
    • /
    • 2004
  • Chemical pneumonitis is caused by the inhalation of noxious chemical substances and is a cause of occupational lung disease. Nitric acid, which is a one of the common air pollutants and a potential oxidant for refining and cleansing of metals, has a chance for occupational and environmental exposure. A 52-year-old man visited our hospital due to coughing and dyspnea after the inhalation of nitric acid fumes at his workplace. He had conditions of tachypnea (respiratory rate 26 /min) and hypoxemia ($PaO_2$ 42.6 mmHg, $SaO_2$ 80.2% in room air) in our emergency department. The chest radiographs showed diffuse interstitial infiltrates and ground glass opacity in both lungs. The patient made improvements in clinical symptoms and chest radiography after being given a supply of oxygen, antibiotics, and bronchodilator therapy without systemic glucocorticoid therapy. On his follow up visit after 4 weeks, he showed no symptoms and sequelae, and the pulmonary function test showed a normal pulmonary function.

Determination of Phantom Scatter Factors for Small Photon Fields (소조사면 광자선의 팬톰산란인수 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.106-111
    • /
    • 2009
  • Total scatter factor ($S_{cp}$), head scatter factor ($S_c$) and phantom scatter factor ($S_p$) are very important for accurate radiation therapy at stereotactic radiosurgery (SRS) with irregular field shape using micro-MLC and intensity modulated radiation therapy (IMRT) including many small field sizes. In this study we measured and compared $S_{cp}$ with reference ion chamber, pinpoint chamber and diode detector and adapted the resuls form diode detector. Head scatter factors for small field sizes were also measured with diode detector covered 1.5 cm-thick solid water build-up cap. Some errors like as electron contamination of 1~3% were included in the values of Sc but trend of total results of $S_c$ was coincided with basic theory. Phantom scatter factors for small field sizes were calculated form $S_{cp}$ and $S_c$. The results of $S_p$ were compared and were well-agreed with those of other authors.

  • PDF

Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator (6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구)

  • Lee, Cheol-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

Residual Radioactivity Investigation & Radiological Assessment for Self-disposal of Concrete Waste in Nuclear Fuel Processing Facility (콘크리트 폐기물의 자체처분을 위한 잔류방사능 조사 및 피폭선량평가)

  • Seol, Jeung-Gun;Ryu, Jae-Bong;Cho, Suk-Ju;Yoo, Sung-Hyun;Song, Jung-Ho;Baek, Hoon;Kim, Seong-Hwan;Shin, Jin-Seong;Park, Hyun-Kyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.2
    • /
    • pp.91-101
    • /
    • 2007
  • In this study, domestic regulatory requirement was investigated for self-disposal of concrete waste from nuclear fuel processing facility. And after self-disposal as landfill or recycling/reuse, the exposure dose was evaluated by RESRAD Ver. 6.3 and RESRAD BUILD Ver.3.3 computing code for radiological assessments of the general public. Derived clearance level by the result of assessments for the exposure dose of the general public is 0.1071Bq/g (3.5% enriched uranium) for landfill and $0.05515Bq/cm^2$ (5% enriched uranium) for recycling/reuse respectively. Also, residual radioactivity of concrete waste after decontamination was investigated in this study. The result of surface activity is $0.01Bq/cm^2\;for\;{\alpha}-emitter$ and the result of radionuclide analysis for taken concrete samples from surface of concrete waste is 0.0297Bq/g for concentration of $^{238}U$, below 2w/o for enrichment of $^{235}U$ and 0.0089Bq/g for artificial contamination of $^{238}U$ respectively. Therefore, radiological hazard of concrete waste by self-disposal as landfill and recycling/reuse is below clearance level to comply with clearance criterion provided for Notice No.2001-30 of the MOST and Korea Atomic Energy Act.

  • PDF