• 제목/요약/키워드: 방사선방어용앞치마

검색결과 2건 처리시간 0.014초

방사선방어용앞치마(Apron)의 차폐율과 균일성 측정을 통한 성능평가 연구 (A study on performance evaluation of Apron by shielding rate and uniformity)

  • 유세종;임창선;심규란
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, we quantitatively analyzed the data by measuring the radiation shielding rate and uniformity in order to evaluate the performance of an Apron. In addition, storage conditions were also evaluated. The uniformity measurement was performed by evaluating the Apron DICOM images using a PACS program. The experiment was intended for 51 Aprons being used in three hospitals in the Daejeon area. The radiation shielding rate and uniformity were measured per lead equivalent for 0.25 mmPb, 0.35 mmPb, and 0.5 mmPb. As a result, the higher lead equivalents were, the greater differences in the non-uniformity between the top part and the bottom part became (p=0.020). In all hospitals, regarding the non-uniformity of four places in Aprons, all showed statistically significant differences (p<0.01). The average value of the transmitted radiation dose showed less difference (p=0.005) in the bottom right than in the upper right but was statistically significant. There have been no marks of manufacturing date or the date of purchase in the Apron.

피부선량을 기준으로 0.511 MeV 감마선에 대한 납 차폐체의 산란선 및 차폐 효율 분석 (Analysis of Scattering Rays and Shielding Efficiency through Lead Shielding for 0.511 MeV Gamma Rays Based on Skin Dose)

  • 장동근;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.259-264
    • /
    • 2020
  • Radiation causes radiation hazards in the human body. In Korea, a case of radiation necrosis occurred in 2014. In this study, the scatter and shielding efficiency according to lead shielding were classified into epidermis and dermis for 0.511 MeV used in nuclear medicine. In this study, experiments were conducted using the slab phantom that represents calibration and the dose of human trunk. Experimental results showed that the shielding rate of 0.25 mmPb was 180% in the epidermis and 96% in the dermis. Shielding at 0.5mmPb showed shielding rates of 158%in the epidermis and 82% in the dermis. As a result of measuring the absorbed dose by subdividing the thickness of the dermis into 0.5 mm intervals, when the shielding was carried out at 0.25 mmPb, the dose appeared to be about 120% at 0.5 mm of the dermis surface, and the dose was decreased at the subsequent depth. Shielding at 0.5 mmPb, the dose appeared to be about 101% at the surface 0.5 mm, and the dose was measured to decrease at the subsequent depth. This result suggests that when lead aprons are actually used, the scattering rays would be sufficiently removed due to the spaces generated by the clothes and air, Therefore, the scattered ray generated from lead will not reach the human body. The ICRU defines the epidermis (0.07), in which the radiation-induced damage of the skin occurs, as the dose equivalent. If the radiation dose of the dermis is considered in addition, it will be helpful for the evaluation of the prognosis for radiation hazard of the skin.