• Title/Summary/Keyword: 방사선량 평가

Search Result 608, Processing Time 0.032 seconds

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Flow Characteristics Evaluation in Reactor Coolant System for Full System Decontamination of Kori-1 Nuclear Power Plant (고리1호기 계통제염을 위한 원자로냉각재내 유동 특성 평가)

  • Kim, Hak Soo;Kim, Cho-Rong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.389-396
    • /
    • 2018
  • The Kori-1 Nuclear Power Plant (NPP), WH 2-Loop Pressurized Water Reactor (PWR) operated for approximately 40 years in Korea, was permanently ceased on June 18, 2017. To reduce worker exposure to radiation by reducing the dose rate in the system before starting main decommissioning activities, the permanently ceased Kori-1 NPP will be subjected to full system decontamination. Generally, the range of system decontamination includes Reactor Pressure Vessels (RPV), Pressurizer (PZR), Steam Generators (SG), Chemical & Volume Control System (CVCS), Residual Heat Removal System (RHRS), and Reactor Coolant System (RCS) piping. In order to decontaminate these systems and equipment in an effective manner, it is necessary to evaluate the influence of the flow characteristics in the RCS during the decontamination period. There are various methods of providing circulating flow rate to the system decontamination. In this paper, the flow characteristics in Kori-1 NPP reactor coolant according to RHR pump operation were evaluated. The evaluation results showed that system decontamination using an RHR pump was not effective at decontamination due first to impurities deposited in piping and equipment, and second to the extreme flow unbalance in the RCS caused deposition of impurities.

An Analysis of Domestic Experimental Results for Soil-to-Crops Transfer Factors of Radionuclides (주요 핵종의 토양-작물체 전이 계수의 국내 실험 결과에 대한 분석)

  • Jun, In;Choi, Young-Ho;Keum, Dong-Kwon;Kang, Hee-Seok;Lee, Han-Soo;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.211-217
    • /
    • 2006
  • For more realistic assessment of Korean food chain radiation doses due to the operation of nuclear facilities, it is required to use domestically produced data for radionuclide transfer parameters in crop plants. This paper analyzed results of last about 10 year's studies on radionuclide transfer parameters in major crop plants by the Korean Atomic Energy Research Institute, comparing with the published international data, and consequently suggested the proper parameters to use. The trends of transfer parameter shows normal distributions if we have a lot of experimental data, but some radionuclides showed enormous variations with the environment of experimental, crops and soils. These transfer factors can be used to assess realistic radiation doses or to predict the doses in crops for normal operation or accidental release. Some kinds of parameter can be produced as conservatives or fragmentary results because soil-to-plant transfer factors were measured through greenhouse experiments which sometimes showed improper field situations. But these parameters mentioned in this paper can be representative of the status of Korean food chain than that of foreign country.

Evaluation of Countermeasures Effectiveness in a Radioactively Contaminated Urban Area Using METRO-K : The Implementation of Scenarios Designed by the EMRAS II Urban Areas Working Group (METRO-K를 사용한 방사능으로 오염된 도시지역에서 대응행위효과 평가 : EMRAS II 도시오염평가분과 시나리오의 이행)

  • Hwang, Won-Tae;Jeong, Hae-Sun;Jeong, Hyo-Joon;Kim, Eun-Han;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.108-115
    • /
    • 2012
  • The Urban Areas Working Group within the EMRAS-2 ($\underline{E}$nvironmental $\underline{M}$odelling for $\underline{RA}$diation $\underline{S}$afety, Phase 2), which has been supported by the IAEA (International Atomic Energy Agency), has designed some types of accidental scenarios to test and improve the capabilities of models used for evaluation of radioactive contamination in urban areas. For the comparison of the results predicted from the different models, the absorbed doses in air were analyzed as a function of time following the accident with consideration of countermeasures to be taken. Two kinds of considerations were performed to find the dependency of the predicted results. One is the 'accidental season', i.e. summer and winter, in which an event of radioactive contamination takes place in a specified urban area. Likewise, the 'rainfall intensity' on the day of an event was also considered with the option of 1) no rain, 2) light rain, and 3) heavy rain. The results predicted using a domestic model of METRO-K have been submitted to the Urban Areas Working Group for the intercomparison with those of other models. In this study, as a part of these results using METRO-K, the countermeasures effectiveness in terms of dose reduction was analyzed and presented for the ground floor of a 24-story business building in a specified urban area. As a result, it was found that the countermeasures effectiveness is distinctly dependent on the rainfall intensity on the day of an event, and season when an event takes place. It is related to the different deposition amount of the radionuclides to the surfaces and different behavior on the surfaces following a deposition, and different effectiveness from countermeasures. In conclusion, a selection of appropriate countermeasures with consideration of various environmental conditions may be important to minimize and optimize the socio-economic costs as well as radiation-induced health detriments.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

400 MeV/nucleon 12C Ions Shielding Benchmark Calculations using MCNPX with Different Nuclear Data Libraries (400 MeV/nucleon 12C 이온의 MCNPX 와 핵자료를 이용한 차폐 벤치마킹 계산)

  • Shin, Yun Sung;Kim, yong min;Kim, dong hyun;Jung, nam suk;Lee, hee seock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.295-300
    • /
    • 2015
  • There are various type of particle accelerators such as Kyoungju 100-MeV proton beam accelerator in Korea. And Korea plans to build large particle accelerator such as heavy ion accelerator and 4th generation light source facility. The accelerated high energy particles of these facility produce 2nd neutron after nuclear reaction with target materials. And then these 2nd neutron activate structural materials and surrounding environment. Accordingly, it is important to consider the activation and shielding calculation on design of facility for safety operation. In this study, we tried to calculate and compare the neutron flux from the interaction $^{la}150$ beam with target material(Cu) according to thickness of iron and concrete shielding material by MCNPX 2.7 with nuclear library JENDL/HE 07and la150. To verify the properties of nuclear library, we compared computational results with experimental value. These results can be used for dose evaluation technology in planning of the shielding of large particle accelerator.

Evaluation of Xerostomia Following Intensity Modulated Radiotherapy (IMRT) for Head and Neck Cancer Patients (세기조절방사선치료를 시행받은 두경부암 환자군에서 구강건조증지표 분석)

  • Lee, Seok-Ho;Kim, Tae-Hyun;Chie, Eui-Kyu;Im, Hyun-Shun;Im, En-Shil;Ryu, Jun-Sun;Jung, Yoo-Seok;Park, Sung-Yong;Kim, Joo-Young;Pyo, Hong-Ryull;Shin, Kyung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.106-114
    • /
    • 2004
  • Purpose : This study was done to evaluate xerostomia fellowing intensity modulated radiotherapy for patients with head and neck cancer, and to analyze the correlation between the dosimetric parameters and xerostomia parameters. Materials and Methods : From February till October 2003, 13 patients with 3 months of follow-up were evaluated for xerostomia after being treated for head and neck cancer with IMRT. Their median age was 57 years(range: 43$\~$77). Xerostomia were assessed with a 4-question xerostomia questionnaire score (XQS) and a test for salivary flow rates (unstimulated and stimulated). The patients were also given a validated LENT SOMA scale (LSC) questionnaire. The evaluations were completed before radiation therapy (pre-RT) and at 1 and, 3 months after radiation therapy (RT). We evaluated xerostomia at pre-RT, 1 and, 3 months after RT. The association between the xerostomia parameters (XQS and LSC) and salivary flow rates (unstimulated and stimulated: USFR and SSFR) was assessed at 1 and 3 months after RT. Resrlts : All 13 patients showed no significant changes in XQS, LSC and Salivary Flow rates. As a result, we couldn't find out about xerostomia development. Based on the total mean parotid dose, 3,500 cGy, we divided these patients into two groups. The 8 patients (<3,500 cGy) showed no significant changes in XQS, LSC and Salivary Flow rates However, in 5 Patients ($\geq$3,500 cOGy), there was a significant increase in USFR and, SSFR at 3 months after RT, and for the XQS and, LSC at 1 and 3 months after RT. The correlation between XQS and, LSC, and USFR and, SSFR in ail patients (13) was significant at 3 months after RT. The correlation had a tendency to the decrease for USFR and, SSFR in proportion to the increase of XQS and, LSC. Conclusion : Based on the results of this study, IMRT seem to be an effective treatment to significantly decrease the xerostomia. XQS and, LSC seem to be a effective tool for predicting the xerostomia. A total parotid gland mean dose of <3,500 cGy should be a planning goal if substantial sparing of the gland function is desired. Furthermore, patients should be enrolled in a study to define a more accurate threshold dose for the parotid gland.

The Use of Normal Tissue Complication Probability to Predict Radiation Hepatitis (간암의 정상조직손상확률을 이용한 방사선간염의 발생여부 예측가능성에 관한 연구)

  • Keum Ki Chang;Seong Jinsil;Suh Chang Ok;Lee Sang-wook;Chung Eun Ji;Shin Hyun Soo;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.277-282
    • /
    • 2000
  • Purpose : Though It has been known that the to tolerance of the liver to external beam irradiation depends on the irradiated volume and dose, few data exist which Quantify this dependence. However, recently, with the development of three dimensional (3-D) treatment planning, have the tools to Quantify the relationships between dose, volume, and normal tissue complications become available. The objective of this study is to investigate the relationships between normal tissue complication probabili쇼 (WCP) and the risk of radiation hepatitis for patients who received variant dose partial liver irradiation. Materials and Methods : From March 1992 to December 1994, 10 patients with hepatoma and 10 patients with bile duct cancer were included in this study. Eighteen patients had normal hepatic function, but 2 patients (prothrombin time 73$\%$, 68$\%$) had mild liver cirrhosis before irradiation. Radiation therapy was delivered with 10MV linear accelerator, 180$\~$200 cGy fraction per day. The total dose ranged from 3,960 cGy to 6,000 cGy (median dose 5,040 cGy). The normal tissue complication probability was calculated by using Lyman's model. Radiation hepatitis was defined as the development of anicteric elevation of alkaline phosphatase of at least two fold and non-malignant ascites in the absence of documented progressive. Results: The calculated NTCP ranged from 0.001 to 0.840 (median 0.05). Three of the 20 patients developed radiation hepatitis. The NTCP of the patients with radiation hepatitis were 0.390, 0.528, 0.844(median : 0.58$\pm$0.23), but that of the patients without radiation hepatitis ranged fro 0.001 to 0.308 (median .0.09$\pm$0.09). When the NTCP was calculated by using the volume factor of 0.32, a radiation hepatitis was observed only in patients with the NTCP value more than 0.39. By contrast, clinical results of evolving radiation hepatitis were not well correlated with NTCP value calculated when the volume factor of 0.69 was applied. On the basis of these observations, the volume factor of 0.32 was more correlated to predict a radiation hepatitis. Conclusion : The risk of radiation hepatitis was increased above the cut-off value. Therefore the NTCP seems to be used for predicting the radiation hepatitis.

  • PDF

The Evaluation of Radiation Therapy and Combined-modality Therapy for Non-small-cell Lung Cancer in Elderly (고령의 비소세포성폐암 환자의 방사선 및 병용치료에 대한 효과 평가)

  • Yoon, Won-Sup;Yang, Dae-Sik;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.101-108
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To compare radiation therapy alone to combined modality therapy about survival rate and tolerance of elderly patients ($70=or{\geq}$) with non-small-cell lung cancer (NSCLC). $\underline{Materials\;and\;Methods}$: Between 1998 and 2002, 57 patients given radiation therapy due to NSCLC (Stage III) were analysed retrospectively. Radiation therapy alone (RT), concurrent chemoradiation (CRT), and sequential chemoradiation (SCRT) was done to 33, 16 and 8 patients, respectively. Patients' median age was 74 (range $70{\sim}85$). Male and female are 51 patients and 6 patients, respectively. 23 patients were stage IIIa and 34 were stage IIIb. Patients' characteristic distribution of RT and CRT was not significantly different except mass size that RT has a bigger than CRT. The fraction size of radiation therapy was 1.8 Gy in CRT and $1.8{\sim}3\;Gy$ in other groups. Total radiation dose was $51{\sim}63\;Gy$ according to the fraction size. If the prescribed total radiation dose was successfully irradiated, we stated that it was completion of radiation therapy. $\underline{Results}$: 52 patients were dead. Median period of radiation therapy was as follow: RT, 35 days, CRT, 60.5 days and SCRT, 35 days. Overall median survival time (MST) was 10.1 months. The 1 yr- and 2 yr-overall survival rate was 39.8% and 17.6%, respectively. MST of RT, CRT and SCRT was 8.9, 8.2 and 11.7 months, respectively. The 1 yr survival rate of RT, CRT and SCRT was 38.4%, 37.5% and 50% (not significant). Patients given incomplete radiation therapy were 12 (RT, 5 CRT, 6 SCRT, 1). N stage (p=0.081) and the difference of treatment methods (p=0.079) were the factors affecting incompletion of radiation therapy, but it was not significant. In case of combined-agents chemotherapy, 4 of 8 ceased radiation therapy. T stage ($T{\geq}3$), mass size (${\geq}5\;cm$), Karnofsky performance scale (${\leq}70$) and completion of radiation therapy were the prognostic factors in uni- and multi-variate analysis. $\underline{Conclusion}$: In elderly patients with NSCLC, radiation therapy alone was a treatment method with similar survival period compared with other methods. Generally, patients given radiation therapy alone was tolerable to a treatment. Before planning concurrent chemoirradiation in elderly patients with NSCLC, physicians pay attention to a selection of patients and chemotherapy agents considering general condition and toxicity.

Image Quality Evaluation in Computed Tomography Using Super-resolution Convolutional Neural Network (Super-resolution Convolutional Neural Network를 이용한 전산화단층상의 화질 평가)

  • Nam, Kibok;Cho, Jeonghyo;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Lee, Dahye
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.211-220
    • /
    • 2020
  • High-quality computed tomography (CT) images enable precise lesion detection and accurate diagnosis. A lot of studies have been performed to improve CT image quality while reducing radiation dose. Recently, deep learning-based techniques for improving CT image quality have been developed and show superior performance compared to conventional techniques. In this study, a super-resolution convolutional neural network (SRCNN) model was used to improve the spatial resolution of CT images, and image quality according to the hyperparameters, which determine the performance of the SRCNN model, was evaluated in order to verify the effect of hyperparameters on the SRCNN model. Profile, structural similarity (SSIM), peak signal-to-noise ratio (PSNR), and full-width at half-maximum (FWHM) were measured to evaluate the performance of the SRCNN model. The results showed that the performance of the SRCNN model was improved with an increase of the numbers of epochs and training sets, and the learning rate needed to be optimized for obtaining acceptable image quality. Therefore, the SRCNN model with optimal hyperparameters is able to improve CT image quality.