• Title/Summary/Keyword: 방사선량 평가

Search Result 608, Processing Time 0.022 seconds

Characteristic Evaluation of Exposed Dose with NORM added Consumer Product based on ICRP Reference Phantom (ICRP 기준팬텀 기반의 천연방사성핵종이 포함된 가공제품 사용으로 인한 피폭선량 특성 평가)

  • Yoo, Do Hyeon;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.159-167
    • /
    • 2014
  • In Korea, July 2012, the law as called 'Act on Safety Control of Radioactive Rays Around Living Environment' was implemented to control the consumer product containing Naturally Occurring Radioactive Material (NORM), but, there are no appropriate database and effective dose calculation system. The aim of this study was to develop evaluation technique of the exposure dose with the use of the consumer products containing NORM and to understand the characteristics of the exposed dose according to the radiation type and energy. For the evaluate of exposure dose, the ICRP reference phantom was simulated by the MCNPX code based on Monte Carlo method, and the minimum, medium, maximum energy of alphas, betas, gammas from the representative NORM of Uranium decay series were used as the source term in the simulation. The annual effective doses were calculated by the exposure scenario of the consumer product usage time and position. Short range of the alpha and beta rays are mostly delivered the dose to the skin. On the other hand, the gamma rays mostly delivered the similar dose to all of the organs. The results of the annual effective dose with $1Bq{\cdot}g^{-1}$ radioactive stone-bed and 10% radioactive concentration were employed with the usage time of 7 hours 50 minute per day, the maximum annual effective dose of alphas, betas, gammas were calculated 0.0222, 0.0836, $0.0101mSv{\cdot}y^{-1}$, respectively.

고선량율 근접치료의 위험도 분석

  • 최진호;이레나;이상훈;이세병;이희석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.57-57
    • /
    • 2003
  • 목적 : 미국 NRC 의 위험도 평가 방법론(NUREG/CR-6642)에 국내에서 시행되는 고선량율 근접치료의 표준입력 자료를 대입하여 고선량율 근접치료시 위험도를 정량적으로 산출하고 그 값을 비교하고자 한다. 대상 및 방법 : 고선량율 근접치료 시스템에 대한 위험도 평가를 위해 국내에서 고선량율 근접치료를 시행하고 있는 17개 의료기관으로부터 방사성동위원소의 설치와 폐기시의 방사능, 선원의 유형, 연간 총 치료회수 등 기초 자료를 수집하였다. 이로부터 방사성동위원소의 평균세기 연간 치료회수 등을 미국 NRC의 위험도 평가 방법론의 데이터베이스에 입력하여 고선량율 근접치료의 직무별, 피폭인의 종류, 정상상태와 사고 등의 형태에 따라 그 위험도를 구하였다. 결과 : 국내 고선량율 근접치료의 위험도는 미국 NRC의 위험도 평가 방법론에 따른 데이터베이스의 입력 결과 일반인의 정상상태와 사고 그리고 방사선종사자의 정상상태와 사고 시에 따라 그 위험도가 1.52-01, 2.96-03, 8.64-01, 3.32-02 rem/yr로 산출되었고 그 값을 미국 NRC의 값과 비교하였다. 결론 : 고선량율 근접치료 시 미국 NRC의 위험도 결과보다는 국내의 경우 수배 정도 높게 계산되었고 일반인과 방사선종사자, 정상상태와 사고, 직무별 패턴 등은 동일한 것으로 간주된다.

  • PDF

The Evaluation of Measuring about Natural Background Radiation according with Camping Place (캠핑장소에 따른 자연방사선량 관한 측정 평가)

  • Jung, Hongmoon;Won, Doyeon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.117-120
    • /
    • 2015
  • The number of campers has been consistently growing thanks to the introduction of a five-day work week and the time increase for a leisure. Thus, many types of facilities for camping are constructed. For instance, there are gravel camp site, which is called crushed stone, and normal soil camp site in case of private camp sites. The amount of natural background radiation, measured from site to site, was analyzed. The value of soil camp site was lower than that of crushed stone camp site. And the amount of natural background radiation from normal camp site was also lower than that from the artificial shade made by tarp. Consequently, it is noted that normal soil camp site with the plenty of woods should be chosen for camping place in order to avoid natural background radiation.

Application of the Two-Dosimeter Algorithm for Effective Dose Evaluations based on ICRP Publication 103 (ICRP 103 방사선방호 체계 하에서 유효선량 평가를 위한 Two-Dosimeter Algorithm의 적용방안)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.154-159
    • /
    • 2011
  • To evaluate the radiation exposure of workers participating in task where high radiation exposure is expected, two-dosimeter is typically provided radiation workers, one on the chest and the other on the back, at Korean nuclear power plants (NPPs). In a previous study, the NCRP (55:50) algorithm was selected as the optimal two-dosimeter algorithm (TDA) with various field tests and this TDA has been applied to all Korean NPPs since 2006. In 2007, the International Commission on Radiological Protection (ICRP) published the new ICRP recommendation, ICRP 103, which provides the revised weighting factors for both radiation and tissues and the new reference phantom. In this study, the applicability of current NCRP (55:50) algorithm at Korean NPPs for ICRP 103 was analyzed. As a result, it was found that the NCRP (55:50) algorithm is still effective to estimate the effective dose of workers under ICRP 103.

Reference Dosimetry and Calibration of Glass Dosimeters for Cs-137 Gamma-rays (연구용 세슘-137 조사기에 대한 흡수선량 측정과 유리선량계 교정에 관한 연구)

  • Moon, Young Min;Rhee, Dong Joo;Kim, Jung Ki;Kang, Yeong-Rok;Lee, Man Woo;Lim, Heuijin;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.140-144
    • /
    • 2013
  • In this research, the glass dosimeter was calibrated to measure the standard absorbed dose of the Cs-137 irradiator and absorbed dose in a biological sample. Absorbed dose in water for Cs-137 gamma ray was determined by the IAEA TRS-277 protocol. The PTW-TM30013 ion chamber and the PTW-TM41023 water phantom were utilized for measuring absorbed dose and the value was compared with the reading from DoseAce GD-302M glass dosimeter from Asahi Techno Glass Corporation for its calibration. The uncertainty of measurement ($1{\sigma}$) of the calibrated glass dosimeter was 2.7% and this result would be applied to improve the accuracy in measurement of absorbed dose in a biological sample.

3차원 조형 방사선치료계획 장비 CorePlan의 유용성 평가

  • 강영남;장지선;강대규;박성일;최일봉;유치훈;강상욱;임병완;신성균
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.33-33
    • /
    • 2003
  • 목적 : 현재 국내에서 사용되고 있는 방사선치료계획 장비는 거의 모든 방사선종양학과에서 외국 회사의 제품을 사용하고 있는 실정이다. 본 연구는 국내 기술로 개발된 3 차원 조형 방사선치료계획 장비인 Core Plan의 선량계산 알고리즘의 정확성 및 방사선 치료계획 장비로서의 유용성에 관해 평가하고 본 장비의 특징에 대해 간략히 소개하고자 한다. 재료 및 방법 : 본 연구는 2002 년 11 월에 가톨릭대학교 성모병원 방사선종양학과와 서울씨앤제이의 연구계약에 의해 시행되었다. 본 장비에 대한 평가는 방사선분포 및 계산상의 정확성과 임상적용시의 유용성의 관점에서 시행되었다. 본 장비에서 이용된 광자선 선량계산은 Clarkson-Cunningham 모델이며 전자선 선량계산은 2.5D Hogstrom 알고리즘이다. 방사선분포 및 계산상의 정확성 평가를 위하여 방사선치료 장비는 본 병원이 보유한 Clinac 2100CD (Varian, USA)를 이용하였고 폴리스티렌 팬텀과 필름 및 이온 전리함을 이용하여 방사선분포 및 계산상의 정확성을 평가하였다. 방사선분포의 평가 방법은 필름을 이용한 방사선분포의 중심부단면 선량분포와 CorePlan 에서 재현된 방사선분포의 동일면 선량분포를 비교하였다. 임상적용은 2003 년 3 월부터 7 월까지 방사선치료를 받은 50 명의 환자를 대상으로 분석하였다. 본 시험에 적용된 환자는 본 병원이 보유한 3 차원 방사선치료계획 장비인 Prowess 3D (SSGI Inc., USA)를 이용하여 실제 치료된 환자들이며 이 환자를 대상으로 CorePlan에서 동일하게 재현하여 비교하였다. 결과 및 결론 : 방사선분포 및 계산상의 정확성 평가에서는 실제 측정된 결과와 CorePlan에서 재현된 결과가 모두 $\pm$3% 이내로 평가되었다. 50 명의 환자를 대상으로 시행한 임상시험 결과 Prowess 3D에서 나타낸 결과와 비교하여 두경부에서는 1.678%, 흉부 1.578%, 복부 1.271%의 선량값의 오차를 보였다. 본 연구를 진행하는 과정에서 많은 부분의 프로그램 수정이 있었으며 실제임상에 필요한 부분에 대한 추가 및 보완이 이루어졌다. 앞으로 진행될 과정은 실제임상의 사용에 필요한 부분의 계속적인 업그레이드와 전자선에 대한 방사선분포 및 계산정확성 평가, 임상적용에 있어서 Prowess3D 뿐만 아니라 다양한 방사선 치료계획 장비와의 비교를 할 예정이다.

  • PDF

ANISN-MCNP 코드를 이용한 월성2호기 반응도제어기구 방사선흐름해석

  • 김용일;진영권;김교윤
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.269-274
    • /
    • 1996
  • 월성원자력발전소 2호기와 같은 CANDU 6형 원자로의 반응도제어기구 설치대에는 여러 반응도제어기구가 삽입되기때문에 원자로심으로부터의 방사선흐름현상으로 인한 방사선피폭이 예상될 수 있는 위치이다. 좁고 긴 반응도제어기구 도관에서의 방사선 흐름으로 인한 반응도제어기구 설치대에서의 방사선량을 예측하기 위해 몬테 칼로 MCNP 코드를 1차원 각분할법 코드인 ANISN과 연계하여 사용하였다. 월성원자력2호기의 상단차폐해석을 위한 ANISN 계산, 도관의 방사선흐름을 평가하기 위한 MCNP 계산, 그리고 반응도제어기구 설치대에서의 방사선량율 평가를 위한 MCNP 계산등 3단계 계산 기법의 적응이 시도되었다.

  • PDF

Radiation Exposure on Radiation Workers of Nuclear Power Plants in Korea : 2009-2013 (국내 원전 종사자의 방사선량 : 2009-2013)

  • Lim, Young-khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • Although the perfomance indicators of the nuclear power plants in Korea show optimal, it requires detailed analysis and discussion centered on the radiation dose. As analysis methods, analysis on the radiation dose of nuclear power plants over the past five years was assessed by comparing the relevant radiation dose of radiation workers and per capita average annual radiation dose of the world's major nuclear power stations was also analyzed. The radiation workers over the annual radiation dose limit of 50 mSv were not. The contrast ratio of the radiation exposure according to the reactor type was the normal operation of PHWR was 6.2% higher than those of the PWR. This shows the radiation work of PHWR during normal driving operation is much more than those of PWR. According to the Performance Indicators of the World Association of Nuclear Operator, the annual radiation dose per unit in 2013 showed 527 man-mSv of Korea is the best country among the major nuclear power generating states, the world average was 725 man-mSv. The annual per capita radiation dose is about 80% less than 1 mSv of the public dose limit and also the average per capita dose showed a very low level as 0.82 mSv. Workers in related organizations showed 1.07 mSv, the non-destructive inspection agency workers showed 3.87 mSv. The remarkable results were due to radiation reduced program such as development of radiation shielding and radiation protection. In conclusion, the radiation exposured dose of nuclear power plants workers in Korea showed a trend which is ideally reduced. But more are expected to be difficul and the psychological insecurity against the operation of the nuclear power plants is existed to the residents near the nuclear power plants. So the radiation dose reduction policy and radiation dose follow up study of nuclear power plants will be continously excuted.