• Title/Summary/Keyword: 방사선구역

Search Result 132, Processing Time 0.023 seconds

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

Preliminary Assessment of Radiation Impact from Dry Storage Facilities for PWR Spent Fuel (경수로 사용후핵연료 건식 중간저장시설에 대한 예비 방사선 영향 평가)

  • Kim, T.M.;Baeg, C.Y.;Cha, G.Y.;Lee, W.G.;Kim, S.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.197-201
    • /
    • 2012
  • Annual dose at the boundary of the interim storage facility at normal condition was calculated to estimate the site area of the facility of PWR spent nuclear fuel. In this work, source term was generated by ORIGEN-ARP for 4.5 wt% initial enrichment, 45,000 MWd/MTU burnup and 10 years cooling time. Modeling of the storage facilities and radiation shielding evaluations were conducted by MCNP code depending on the storage capacity. In the case of the centralized storage system, the required site area was found to have the radius of more than 700 m.

Development and Usefulness Evaluation of Virtual Reality Simulator for Education of Spatial Dose Rate in Radiation Controlled Area (방사선관리구역의 공간선량률 교육을 위한 가상현실 시뮬레이터의 개발과 유용성 평가)

  • Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.493-499
    • /
    • 2023
  • This study developed education contents of measuring spatial dose with virtual reality simulation and applied to students majoring radiological science. The virtual reality(VR) contents with measuring spatial dose rate in the radiation controlled area was developed based on the simulation from pilot study. In this simulation, the tube voltage and tube current can be set from 60 to 120 kVp in 10 kVp steps and 10 to 40 mAs in 10 mAs increments, and the distance from source can be set from 30 to 400 cm continuously. Iron and lead shields can be placed between the source and the detector, and shielding thickness can be set by 1 mm increments ranging from 1 to 20 mm. We surveyed to students for evaluating improvement of understanding spatial dose rate between before and after education by VR simulation. The survey was conducted with 5 questions(X-ray exposure factors, effects by distance from the source, effects from using shield, depending on material and thickness of shield, concept and measuring of spatial dose rate) and all answers showed significant improvement. Therefore, this VR simulation content will be well used in education for spatial dose rate and radiation safety environments.

Prediction of Evacuation Time for Emergency Planning Zone of Uljin Nuclear Site (울진원전 방사선비상계획구역에 대한 소개시간 예측)

  • Jeon, In-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.189-198
    • /
    • 2002
  • The time for evacuation of residents in emergency planning zone(EPZ) of Uljin nuclear site in case of a radiological emergency was estimated with traffic analysis. Evacuees were classified into 4 groups by considering population density, local jurisdictions, and whether they ate residents or transients. The survey to investigate the behavioral characteristics of the residents was made for 200 households and included a hypothetical scenario explaining the accident situation and questions such as dwelling place, time demand for evacuation preparation transportation means for evacuation, sheltering place, and evacuation direction. The microscopic traffic simulation model, CORSIM, was used to simulate the behavior of evacuating vehicles on networks. The results showed that the evacuation time required for total vehicles to move out from EPZ took longer in the daytime than at night in spite that the delay times at intersections were longer at night than in the daytime. This was analyzed due to the differences of the trip generation time distribution. To validate whether the CORSIM model fan appropriately simulate the congested traffic phenomena assumable in case of emergency, a benchmark study was conducted at an intersection without an actuated traffic signal near Uljin site during the traffic peak-time in the morning. This study indicated that the predicted output by the CORSIM model was in good agreement with the observed data. satisfying the purpose of this study.

공기정화필터 프레임 재사용과 그에 따른 효과 고찰

  • 윤철종;송대원;장동철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.194-195
    • /
    • 2005
  • 방사선관리구역 내에서 발생되는 많은 양(발전소별 연간 약$100{\sim}700$개 정도)의 사용 후 공기정화 필터는 고체 폐기물 드럼의 단면적 보다 넓어 별도로 필터를 압축하거나 분해 작업 없이는 폐기물로 직접 처리가 곤란하다. 처리 시 많은 양의 분진이 발생하여 작업자의 내부피폭 가능성 및 많은 양의 고체 폐기물이 발생할 수 있는 잠재성이 있어 시료분석 결과 오염된 필터 내지는 바로 드럼 처리하여 내부 피폭 가능성을 미연에 방지하고 필터 프레임은 재사용을 유도하여 폐기물 저감화, 작업환경 개선 및 경제적인 이익을 창출할 수 있다. 영광 3발전소와 울진 3발전소의 경우 타 발전소에 비해 방사선관리구역 내 공기정화 처리기의 설치수량이 많아(약 700개/년) 공기정화필터가 매년 다수 발생되고 있으며, 이를 전량 드럼 처리 시 고체폐기물 드럼이 더 발생하게 되어 영구처분비용의 증가를 초래하게 된다. 발전소 전체적으로는 약 3,500개/년의 폐필터가 발생되고 있다. 이렇게 발생되는 공기정화필터의 프레임을 재사용함으로써 그 효과는 1) 알루미늄을 포함한 유리섬유를 드럼처리 시 고체방사성 폐기물드럼 생성량 감소 2) 프레임 재사용으로 인한 예산절감 효과 3) 폐필터 분해작업 시 분진에 의한 작업자 체내${\cdot}$외 피폭방지와 작업장 오염 확산 방지 및 환경 개선 4) 작업시간 단축 및 소요인력 감소 효과를 볼 수 있다.

  • PDF