• 제목/요약/키워드: 방사선관련

검색결과 1,061건 처리시간 0.03초

Arthroscopic Management for Pyogenic Arthritis with Positive Culture in the Knee Joint (배양 검사로 증명된 화농성 슬관절염의 관절경적 치료)

  • Baek, Seung-Hoon;Kim, Se Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • 제16권2호
    • /
    • pp.167-174
    • /
    • 2012
  • Purpose: The purpose of this study is investigation of clinical and functional outcomes in homogeneous group with positive culture after arthroscopic management for pyogenic knee arthritis and analysis of factors affecting those outcomes. Materials and Methods: Thirty-two patients with positive culture after arthroscopic management were included. Mean follow-up period was 41.6 months. Clinical evaluation included death related to infection, recurrence, time to normalize erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), duration of administration of intravenous antibiotics and readmission. Radiographic evaluation was performed according to Kellgren and Lawrence. The prevalence of total knee arthroplasty was investigated and functional evaluation included modified Lysholm, Tegner activity and Korean version of the Western Ontario and McMaster Universities (K-WOMAC) score. Results: Staphylococcus aureus was identified in 21 patients. Time to normalize ESR and CRP was 78.0 and 67.6 days, respectively. Two patients died while there were six recurrences and five readmissions. Rate of recurrence was significantly high in patients with chronic renal failure (P=0.034) and incidence of readmission was associated with higher radiographic grade of osteoarthritis and rate of reoperation (P=0.032 and P=0.006, respectively). At the final follow-up, radiographic grade worsened in 21 patients and was associated with those at first visit. Five arthroplasties were performed. Average modified Lysholm score, Tegner activity score and K-WOMAC score were 53.5, 2.7, 44.2 points, respectively. Conclusion: The severity of osteoarthritis on final radiographs was associated with those at first visit. Patients with higher grade of osteoarthritis at first visit showed higher incidence of readmission and those with chronic renal failure demonstrated higher chances of recurrence.

  • PDF

Relationship between Admission and Clinical Features of Children Who Visited the Emergency Department with Seizures (경련을 주소로 응급실을 방문한 아이의 임상양상과 입원과의 관계)

  • Yoon, Sung Kwan;Kim, Eun Young;Yang, Eun Seok;Moon, Kyung Rye;Park, Sang Kee;Park, Young Bong;Rho, Young Il;Cho, Soo Hyeong
    • Clinical and Experimental Pediatrics
    • /
    • 제46권10호
    • /
    • pp.1003-1007
    • /
    • 2003
  • Purpose : To review the seizure-related complaints and analyze the relationship between admission rates and clinical features in children who had visited the emergency department with seizures. Methods : Retrospectively, we reviewed 180 patients(male 100, female 80) suffering from seizures, who had visited to the emergency department of Chosun University Hospital from January 2000 to June 2002. We have analyzed the correlation between admission rate and clinical features such as age, seizure type, seizure duration and individual laboratory findings(CT or MRI, and CSF). Results : Out of 4,865 total children who visited the emergency department, 180 patients(3.7%) were seizure related. The most common seizure type was simple febrile seizure(52.2%). The admission rate of children with seizures was 48.9%. The admission rate according to age, sex and abnormal laboratory findings revealed no significant correlations(P>0.05). There was a significant correlation between admission and both status epilepticus 82.4%(14/17) and complex febrile seizure 63.6%(14/22) (P<0.05). According to the duration of convulsions, admission rates were 41.2% when within five minutes, 60% when six-15 minutes, 58.8% when 16-30 minutes, 85.7% when 30 minutes, to one hour and 66.7% when above one hour of duration. According to the seizure frequency, admission rates of recurrent seizure patients(61.4%=43/70) was higher compared to the first time seizure patients(40.9%=45/110). Conclusion : We found that the admission rate of children visiting the emergency department for seizure treatment was 48.9% and significantly correlated with duration, type and frequency of seizure.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

A Study on the Image Registration Algorithms for the Accurate Application of Multimodality Image in Radiation Treatment Planning (방사선치료 계획시 다중영상 활용의 정확도 향상을 위한 영상정합 알고리즘 분석)

  • 송주영;이형구;최보영;윤세철;서태석
    • Progress in Medical Physics
    • /
    • 제13권4호
    • /
    • pp.209-217
    • /
    • 2002
  • There have been many studies on the application of the reciprocal advantages of multimodality image to define accurate target volume in the Process of radiation treatment planning. For the proper use of the multimodality images, the registration works between different modality images should be performed in advance. In this study, we selected chamfer matching method and mutual information method as most popular methods in recent image registration studies considering the registration accuracy and clinical practicality. And the two registration methods were analyzed to deduce the optimal registration method according to the characteristics of images. Lung phantom of which multimodality images could be acquired was fabricated and CT, MRI and SPECT images of the phantom were used in this study. We developed the registration program which can perform the two registration methods properly and analyzed the registration results which were produced by the developed program in many different images' conditions. Although the overall accuracy of the registration in both chamfer matching method and mutual information method was acceptable, the registration errors in SPECT images which had lower resolution and in degraded images of which data were removed in some part were increased when chamfer matching method was applied. Especially in the case of degraded reference image, chamfer matching methods produce relatively large errors compared with mutual information method. Mutual information method can be estimated as more robust registration method than chamfer matching method in this study because it did not need the prerequisite works, the extraction of accurate contour points, and it produced more accurate registration results consistently regardless of the images' characteristics. The analysis of the registration methods in this study can be expected to provide useful information to the utilization of multimodality images in delineating target volume for radiation treatment planning and in many other clinical applications.

  • PDF

Arm Morbidity after Breast Cancer Treatments and Analysis of Related Factors (유방암 환자의 상지 부작용과 관련 요인)

  • Chun Mi Son;Moon Seong Mi;Lee hye Jin;Lee Eun-Hyun;Song Yeoung Suk;Chung Yong Sik;Park Hee Bung;Kang Seung Hee
    • Radiation Oncology Journal
    • /
    • 제23권1호
    • /
    • pp.32-42
    • /
    • 2005
  • Purpose : To evaluate the incidence of arm morbidity following breast cancer surgery including axillary dissection and to identify related factors. Materials and Methods : One hundred and fifty nine patients were studied using a self-report questionnaire and a clinical examination. Lymphedema, reduction of range of motion in shoulder joint and subjective symptoms (pain, impaired arm movement, numbness, stiffness) were evaluated. As related factors, demographic, oncologic characteristics and types of treatment were analysed. Results : The incidence of lymphedema ($\geqq$2 cm difference comparing to unaffected arm) was $6.3\%$, $10.7\%$, $22.5\%$ and $23.3\%$ at each 10 cm, 20 cm, 30 cm, and 40 cm from wrist. Reduction of range of motion in shoulder joint ($\geqq$ 20 degree difference comparing to unaffected arm) was noted In more than 1/3 patients for flexion, abduction and internal rotation. Especially the reduction of range of motion in internal rotation was severe ($>50\%$ reduction) in 1/3 patients. Approximately 50 to $60\%$ of patients complained impaired arm movement, numbness, stiffness and pain. Body mass index (BMI) was the significant risk factor for lymphedema. Conclusion : Lymphedema was present in 1/3 of patients and the common sites of edema were 30 cm 40 cm proximal from the wrist. Also most severe reduction of range of motion in shoulder joint was with internal rotation. There needs weight control for lymphedema because BMI was the significant risk factor for lymphedema. Also rehabilitation program for range of motion especially internal rotation In shoulder joint should be developed.

Production of Ginsenoside in the Hairy Roots Irradiated by 60Co γ on Panax ginseng C.A Meyer (60Co γ 를 조사한 인삼모상근 돌연변이 세포주의 생장과 Ginsenoside의 생산)

  • Choi, Kyu-Myoung;Kwon, Jung-Hee;Ban, Sung-Hee;Yang, Deok-Cho
    • Journal of Ginseng Research
    • /
    • 제26권4호
    • /
    • pp.219-225
    • /
    • 2002
  • Study was performed to know the effects of Panax ginseng C.A. Meyer hairy root due to $^{60}$ Co ${\gamma}$-ray irradiation. We irradiated the hairy roots under the various $^{60}$ Co ${\gamma}$-ray; 0.5~4 Krad. The growth of hairy roots is inhibited over 3 Krad treatment. The lateral roots are used as a cell line after removing the apical meristem of hairy roots irradiated below 2 Krad. We selected 206 hairy root cell lines having various different growth rates and forms, and incubated in the 1/2 Murashige & Skoog(MS) medium in the absence of hormone. We selected 10 out of 206 showing superior growth. Among those, ${\gamma}$-GHR 70 and ${\gamma}$-GHR 94 showed higher growth; 34.5, 44.7%, respectively. We observed shapable, sizable characteristics according to the width of the primary roots, the process formation of the lateral roots, and the growth of lateral roots. The discriminable cell line showed that primary root is thinner, and has a vigorous growth. 8 out of 10 had much more contents than control in the aspect of the ginsenoside. ${\gamma}$-GHR 59 and ${\gamma}$-GHR 94 showed higher contents; 19, 16.9%, respectively. Therefore, we selected ${\gamma}$-GHR 70, ${\gamma}$-GHR 94 as a superior cell line in the aspect of ginsenoside contents, and growth among those irradiated by ${\gamma}$-ray. According to content of ginsenoside, Rb$_2$ effective in anticancer has 7.5% of ${\gamma}$-GHR 59. Rc, also effective in anticancer showed 16.2% content increasement of ${\gamma}$-GHR 69. It is thought that those lines will be effective in manufacturing ginsenoside. Gene analysis (VNTRP) related to the mutation is in progress.

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • 제3권2호
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Benchmark Results of a Monte Carlo Treatment Planning system (몬데카를로 기반 치료계획시스템의 성능평가)

  • Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • 제13권3호
    • /
    • pp.149-155
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. To compare the speed and accuracies of dose calculations between different developed codes, a benchmark tests were proposed at the XIIth ICCR (International Conference on the use of Computers in Radiation Therapy, Heidelberg, Germany 2000). A Monte Carlo treatment planning comprised of 28 various Intel Pentium CPUs was implemented for routine clinical use. The purpose of this study was to evaluate the performance of our system using the above benchmark tests. The benchmark procedures are comprised of three parts. a) speed of photon beams dose calculation inside a given phantom of 30.5 cm$\times$39.5 cm $\times$ 30 cm deep and filled with 5 ㎣ voxels within 2% statistical uncertainty. b) speed of electron beams dose calculation inside the same phantom as that of the photon beams. c) accuracy of photon and electron beam calculation inside heterogeneous slab phantom compared with the reference results of EGS4/PRESTA calculation. As results of the speed benchmark tests, it took 5.5 minutes to achieve less than 2% statistical uncertainty for 18 MV photon beams. Though the net calculation for electron beams was an order of faster than the photon beam, the overall calculation time was similar to that of photon beam case due to the overhead time to maintain parallel processing. Since our Monte Carlo code is EGSnrc, which is an improved version of EGS4, the accuracy tests of our system showed, as expected, very good agreement with the reference data. In conclusion, our Monte Carlo treatment planning system shows clinically meaningful results. Though other more efficient codes are developed such like MCDOSE and VMC++, BEAMnrc based on EGSnrc code system may be used for routine clinical Monte Carlo treatment planning in conjunction with clustering technique.

  • PDF

A Study on the Development Direction of Medical Image Information System Using Big Data and AI (빅데이터와 AI를 활용한 의료영상 정보 시스템 발전 방향에 대한 연구)

  • Yoo, Se Jong;Han, Seong Soo;Jeon, Mi-Hyang;Han, Man Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • 제11권9호
    • /
    • pp.317-322
    • /
    • 2022
  • The rapid development of information technology is also bringing about many changes in the medical environment. In particular, it is leading the rapid change of medical image information systems using big data and artificial intelligence (AI). The prescription delivery system (OCS), which consists of an electronic medical record (EMR) and a medical image storage and transmission system (PACS), has rapidly changed the medical environment from analog to digital. When combined with multiple solutions, PACS represents a new direction for advancement in security, interoperability, efficiency and automation. Among them, the combination with artificial intelligence (AI) using big data that can improve the quality of images is actively progressing. In particular, AI PACS, a system that can assist in reading medical images using deep learning technology, was developed in cooperation with universities and industries and is being used in hospitals. As such, in line with the rapid changes in the medical image information system in the medical environment, structural changes in the medical market and changes in medical policies to cope with them are also necessary. On the other hand, medical image information is based on a digital medical image transmission device (DICOM) format method, and is divided into a tomographic volume image, a volume image, and a cross-sectional image, a two-dimensional image, according to a generation method. In addition, recently, many medical institutions are rushing to introduce the next-generation integrated medical information system by promoting smart hospital services. The next-generation integrated medical information system is built as a solution that integrates EMR, electronic consent, big data, AI, precision medicine, and interworking with external institutions. It aims to realize research. Korea's medical image information system is at a world-class level thanks to advanced IT technology and government policies. In particular, the PACS solution is the only field exporting medical information technology to the world. In this study, along with the analysis of the medical image information system using big data, the current trend was grasped based on the historical background of the introduction of the medical image information system in Korea, and the future development direction was predicted. In the future, based on DICOM big data accumulated over 20 years, we plan to conduct research that can increase the image read rate by using AI and deep learning algorithms.

Korean Clinical Imaging Guidelines for the Appropriate Use of Chest MRI (한국형 흉부 MRI 영상 진단 정당성 권고안)

  • Jiyoung Song;Bo Da Nam;Soon Ho Yoon;Jin Young Yoo;Yeon Joo Jeong;Chang Dong Yeo;Seong Yong Lim;Sung Yong Lee;Hyun Koo Kim;Byoung Hyuck Kim;Kwang Nam Jin;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • 제82권3호
    • /
    • pp.562-574
    • /
    • 2021
  • MRI has the advantages of having excellent soft-tissue contrast and providing functional information without any harmful ionizing radiation. Although previous technical limitations restricted the use of chest MRI, recent technological advances and expansion of insurance coverage are increasing the demand for chest MRI. Recognizing the need for guidelines on appropriate use of chest MRI in Korean clinical settings, the Korean Society of Radiology has composed a development committee, working committee, and advisory committee to develop Korean chest MRI justification guidelines. Five key questions were selected and recommendations have been made with the evidence-based clinical imaging guideline adaptation methodology. Recommendations are as follows. Chest MRI can be considered in the following circumstances: for patients with incidentally found anterior mediastinal masses to exclude non-neoplastic conditions, for pneumoconiosis patients with lung masses to differentiate progressive massive fibrosis from lung cancer, and when invasion of the chest wall, vertebrae, diaphragm, or major vessels by malignant pleural mesothelioma or non-small cell lung cancer is suspected. Chest MRI without contrast enhancement or with minimal dose low-risk contrast media can be considered for pregnant women with suspected pulmonary embolism. Lastly, chest MRI is recommended for patients with pancoast tumors planned for radical surgery.