• Title/Summary/Keyword: 방사상대

Search Result 164, Processing Time 0.026 seconds

Analysis of Relationship between 2-D Fabric Tensor Parameters and Hydraulic Properties of Fractured Rock Mass (절리성 암반의 이차원 균열텐서 파라미터와 수리적 특성 간의 상관성 분석에 관한 연구)

  • Um, Jeong-Gi;Han, Jisu
    • Tunnel and Underground Space
    • /
    • v.27 no.2
    • /
    • pp.100-108
    • /
    • 2017
  • As a measure of the combined effect of fracture geometry, the fabric tensor parameters could quantify the status of the connected fluid flow paths in discrete fracture network (DFN). The correlation analysis between fabric tensor parameters and hydraulic properties of the 2-D DFN was performed in this study. It is found that there exists a strong nonlinear relationship between the directional conductivity and the fabric tensor component estimated in the direction normal to the direction of hydraulic conductivity. The circular radial plots without significant variation of the first invariant ($F_0$) of fabric tensor for different sized 2-D DFN block are a necessary condition for treating representative element volume (REV) of a fractured rock mass. The relative error (ER) between the numerically calculated directional hydraulic conductivity and the theoretical directional hydraulic conductivity decreases with the increase in $F_0$. A strong functional relation seems to exist between the $F_0$ and the average block hydraulic conductivity.

A study on indoor visible light communication localization based on manchester code using walsh code (Walsh code를 이용한 Manchester code 기반 가시광 통신 실내 위치인식에 대한 연구)

  • Kim, Won-yeol;Park, Sang-gug;Cho, Woong-ho;Noh, Duck-soo;Seo, Dong-hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.959-966
    • /
    • 2015
  • In this paper, we propose an indoor visible light communication(VLC) localization using Walsh code which can identify overlapped signals transmitted from the different LED sources as each of orthogonal signal at a receiver and using Manchester code which can eliminate the flicker of LED light and maintain a constant brightness. The proposed system can estimate the relative position of the receiver by using Lambertian radiation properties and trilateration method that are applied to the location information of fixed LED sources and the received signals from them. In order to verify the feasibility of the proposed system, we carried out the simulation in an indoor space with $6{\times}6{\times}1.5m^3$ installed LED lamps of 16. The simulation result shows that the proposed method achieves an average positioning error of 0.0536 m and a maximum positioning error of 0.2977 m.

Analysis of Solute Transport with Steady State Groundwater Flow in Layered Aquifer (정상 지하수흐름을 갖는 층상대수층에서의 용질이동해석)

  • Lee, Seung-Han;Jeong, Il-Mun
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.1
    • /
    • pp.23-34
    • /
    • 1997
  • The Nanji-Do ladnfill is an ill-conditioned reclaimed land without pollution intercepting facilities, and has high ground water table and deep stratum. The purpose of this study is to analyze the solute transport in steady-state groundwater flow and to predict the solute dispersion in Nanji-Do landfill using HST-3D model. As results, the groundwater flows radially outward from the center of No. 1 and No. 2 landfills, and large amount of runoff is moved into Han River. The predicted relative concentration of total dissolved solute(TDS) at two years later was 0.25 in the weathering zone, 0.26 in the lower alluvium, and 0.28 in the upper alluvium. Thus, the further pollution to bottom rock and Han River was predicted by comparing the corresponding present values of 0.29, 0.32 and 0.35.

  • PDF

Basic Dose Response of Fluorescent Screen-based Portal Imaging Device (섬광판을 사용하는 조사문영상기구의 기본적인 선량반응성)

  • Yeo, In-Hwan J.;Yohannes, Yonas;Zhu,Yunping
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.249-255
    • /
    • 1999
  • Purpose : The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDS). Materials and Methods : We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. Results : We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as $7\%$. We also found that scintillation light scattering within the EPID system is an important source of error. Conclusion : This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system.

  • PDF

(Design of RFID Reader Antenna Using Two Orthogonally Oriented 1x2 Sub-Arrays at 433 MHz) (직교형으로 배열된 2개의 1x2서브-어레이를 이용한 433MHz에서 동작하는 RFID 리더용 안테나 설계)

  • Kim Jong-Sung;Park Seung-Mo;Choi Won-Kyu;Seong Nak-Seon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.9 s.339
    • /
    • pp.97-100
    • /
    • 2005
  • An orthogonal antenna is presented for reader application of radio frequency identification (RFID) at 433 MHz. Two 1x2 sub-arrays are orthogonally placed on a ground plane and two different feeding networks are applied to control horizontal and vertical radiation current flows for each sub-array, respectively. Inverted-F structures are used as radiation elements and can generate two linear polarizations by relative current distribution of radiators forming sub-arrays. Antenna gains are 2.7 and 0.4 dBi and isolation between two input ports is less than 25dB.

Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor (유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정)

  • Shin, Sang-Hun;Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Moon, Joo-Hyun;Kim, Sin;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.

Analytical Solutions for a Three-Member Decay Chain of Radionuclides Transport in a Single Fractured Porous Rock (단일균열 다공성암반에서 방사성핵종의 수송에 대한 3단계 붕괴사슬의 해석해)

  • Yu, Young-Woo;Chung, Chang-Hyun;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.453-460
    • /
    • 1994
  • The migration equation is modified for a three-member decay chain in the fracture and porous matrix Analytical solutions are obtained by utilizing Laplace transform the initial conditions of Delta function and Bateman equation. The concentrations for each nuclide of Np$^{237}$ -U$^{233}$ -Th$^{229}$ and U$^{234}$ -Th$^{230}$ -Ra$^{226}$ chains selected from the 4n+1 and 4n+2 chains are plotted by utilizing analytical solutions in the fracture. Retardation coefficient of the nuclides are obtained using those of the granite. The results indicate that the daughter nuclides such as U$^{233}$ , Th$^{229}$ , Th$^{230}$ and Ra$^{226}$ become important at the far field from the repository though there is very small initial inventory in the waste solid or spent fuel, for they are produced by the mother nuclides decayed in the fracture and porous matrix.

  • PDF

Development of Brightness Correction Method for Mosaicking UAV Images (무인기 영상 병합을 위한 밝기값 보정 방법 개발)

  • Ban, Seunghwan;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1071-1081
    • /
    • 2021
  • Remote Sensing using unmanned aerial vehicles(UAV) can acquire images with higher time resolution and spatial resolution than aerial and satellite remote sensing. However, UAV images are photographed at low altitude and the area covered by one image isrelatively narrow. Therefore multiple images must be processed to monitor large area. Since UAV images are photographed under different exposure conditions, there is difference in brightness values between adjacent images. When images are mosaicked, unnatural seamlines are generated because of the brightness difference. Therefore, in order to generate seamless mosaic image, a radiometric processing for correcting difference in brightness value between images is essential. This paper proposes a relative radiometric calibration and image blending technique. In order to analyze performance of the proposed method, mosaic images of UAV images in agricultural and mountainous areas were generated. As a result, mosaic images with mean brightness difference of 5 and root mean square difference of 7 were avchieved.

Physical Properties of Liquid Ammonia Wood for Bending (휨가공을 위한 액체암모니아 처리재의 물리적 성질)

  • Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.52-60
    • /
    • 2003
  • The physical properties of small hardwood and softwood specimens treated with liquid ammonia were investigated. The specimens treated for 4 or 18 hours were compared with the controls. The EMCs of the liquid ammonia treated specimens were higher than those of the controls when conditioned at the same humidities. However once oven-dried they didn't show any significant differences in EMCs. With the increase of liquid ammonia treatment time specimens shrank in radial and tangential directions, but not in longitudinal direction. As liquid ammonia treatment time increased the ultrasonic velocities of specimens decreased and their densities increased, thus their dynamic MOEs decreased. For chestnut specimens the presteamed were more plasticized than the liquid ammonia treated. Incising on the surfaces of specimens didn't improve liquid ammonia permeability in both hardwoods and softwoods. Liquid ammonia treatment was very effective for plasticizing 5 mm thick softwoods. Relative dielectric constants and thermal conductivities were measured with both liquid ammonia treated and control specimens.

Determination of trace boron in steels by prompt gamma-ray activation analysis (즉발감마선방사화분석법에 의한 철강시료 중의 붕소 측정)

  • Kim, I.J.;Cho, K.H.;Paul, R.L.
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.302-306
    • /
    • 2009
  • A trace amount of boron in steel significantly influences its mechanical and physical properties. A prompt gamma ray activation analysis (PGAA) method is used to measure boron in low alloy steel samples of KRISS 101-01-C21~C26. NIST SRMs of 362, 364, 1761 and 1767 serve as the control standards to validate the measurement method. The measured values of the NIST SRMs are consistent with their certified values within the expected uncertainties, except for that of NIST SRM 362. Experimental uncertainties are evaluated according to the guidelines given by the International Organization for Standardization (ISO). The expanded uncertainties are calculated with a coverage factor of 2, at approximately 95% confidence level. The calculated relative expanded uncertainties of boron mass fractions are between 3% and 7% at the mg/kg level. The results are compared with the results measured by the solvent extraction-inductively coupled optical emission spectrometry (ICP/OES) method.