• Title/Summary/Keyword: 방사량

Search Result 1,194, Processing Time 0.023 seconds

Ablation of Remnant Thyroid Tissue with I-131 in Well Differentiated Thyroid Cancer After Surgery (분화성 갑상선암에서 수술 후 I-131을 이용한 잔여 갑상선 조직의 제거 성적)

  • Kim, Yu-Kyeong;Lee, Dong-Soo;Cho, Bo-Yeon;Jeong, Jae-Min;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.339-345
    • /
    • 1997
  • To evaluate the effectiveness of I-131 in ablation of residual thyroid tissue, we analyzed 350 patients with thyroid cancer who were treated with various doses of I-131 after surgery for thyroid cancer Two hundred fifty five patients were treated with 1.1GBq(30mCi) of I-131 for ablation of remnant thyroid and one hundred seventeen patients received more than 2.8GBq(75mCi) of I-131. We determined the effectiveness of ablation by following I-131 whole body scan. Absent visible uptake or minimal uptake in thyroid tissue were considered as successful ablation. Of 255 patients who received doses of 30mCi I-131 therapy, 131 patients(51%) showed successful ablation of residual thyroid tissue with $2.6{\pm}1.7$ times of I-131 therapy. Of 117 patients who received doses of the more than 75mCi I-131, 84 patients(72%) had successful remnant thyroid ablation with $1.6{\pm}1.1$ times of I-131 therapy, According to the extent of surgery, successful ablation rates were 78%, 62%, 54%, 33% in patients who underwent total thyroidectomy, subtotal thyroidectomy, lobectomy and isthmectomy, lobectomy or tumorectomy, respectively. This study showed that ablation of remnant thyroid after surgery with 30mCi I-131 was successful only in 50%. Therefore, in cases of patients with high risk for recurrence, we recommend high dose I-131 for ablation of remnant after total thyroidectomy.

  • PDF

The Results of Curative Concurrent Chemoradiotherapy for Anal Carcinoma (항문암 환자에서 근치적 목적의 동시 항암화학 방사선치료의 결과)

  • Jeong, Jae-Uk;Yoon, Mee-Sun;Song, Ju-Young;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik;Nam, Taek-Keun
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.205-210
    • /
    • 2010
  • Purpose: To evaluate the predictive factors for treatment response and prognostic factors affecting survival outcomes after concurrent chemoradiotherapy (CCRT) for patients with anal squamous cell carcinoma. Materials and Methods: Medical records of forty two patients with histologically confirmed analsquamous cell carcinoma, who had complete CCRT between 1993 and 2008, were reviewed retrospectively. Median age was 61.5 years (39~89 years), and median radiotherapy (RT) dose was 50.4 Gy (30.0~64.0 Gy). A total of 36 patients had equal to or less than T2 stage (85.7%). Fourteen patients (33.3%) showed regional nodal metastasis, 36 patients (85.7%) were treated with 5-fluorouracil (5-FU) plus mitomycin, and the remaining patients were treated by 5-FU plus cisplatinum. Results: The median follow-up time was 62 months (2~202 months). The 5-year overall survival, loco regional relapse-free survival, disease-free survival, and colostomy-free survival rates were 86.0%, 71.7%, 71.7%, 78.2%, respectively. Regarding overall survival, the Eastern Cooperative Oncology Group (ECOG) performance status and complete response were found to be significant prognostic factors on univariate analysis. For multivariate analysis, only the ECOG performance status was significant. No significant factor was found for locoregional relapse-free survival or disease-free survival and similarly for treatment response, no significant factor was determined on logistic regression analysis. There were 7 patients who had local or regional recurrences and one patient with distant metastasis. The only evaluable toxicity in all patients was radiation dermatitis of perianal skin (grade 3), which developed in 4 patients (9.5%) and grade 2 in 22 patients (52.4%). Conclusion: This study revealed that patients with a performance score of ECOG 0-1 survived significantly longer than those with a poorer score. Finally, there was no significant predicting factors tested for treatment response.

Optimum Dose Combination of External Radiation and High Dose Rate ICR in FIGO IB Uterine Cervical Cancer (병기 IB 자궁경부암의 방사선치료에서 외부방사선치료와 고선량율 강내치료의 최적선량 배합)

  • Lee Sang Wook;Suh Chang Ok;Chung Eun Ji;Kim Woo Cheol;Chang Sei Kyung;Keum Ki Chang;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 1996
  • Purpose : To assess the efficacy of high dose rate - intracavitary radio-therapy (HDR-ICR) in the radiotherapy of FIGO stage IB squamous cell carcinoma of uterine cervix and to determine the optimum dose combination scheme of external radiotherapy and ICR to achieve acceptable local control without severe complication. Materials and Methods : One hundred and sixty two patients with FIGO stage Ib squamous cell carcinoma of uterine cervix who received definitive radiotherapy between May 1979 and December 1990 were retrospectively analyzed. All the patients received external radiotherapy combined with HDR-ICR. External dose of 40-46 Gy in 4.5-5 weeks was given to whole pelvis(median 45 Gy) and ICR dose of 30-39 Gy in 10-13 times was given to the point A. Midline shielding was done after 20-45 Gy of external radiotherapy(median 40 Gy) Summation of external dose Plus ICR dose to the point A range were 64.20-95.00 Gy. and mean was 83.94 Gy. We analyzed the local control rate, survival rate, and late complication rate. Rusults : Initial complete response rate was $99.4\%$ for all patients. Overall 5-year survival rate was $91.1\%$ and 5-year disease free survival rate was $90.9\%$. Local failure rate was $4.9\%$ and distant failure rate was $4.3\%$. Tumor size was the only significant prognostic factor. When tumor size greater than 3cm, 5-rear survival rate was $92.6\%$ and less than 3cm, that was $79.6\%$. Late complication rate was $23.5\%$ with $18.5\%$ of rectal complication and $4.9\%$ of bladder complication. Mean rectal dose summation of external midline dose plus ICR rectal point dose was lower in the patients without rectal complication(74.88 Gr) than those with rectal complication (78.87 Gy). Complication rate was increased with low rate of improvement of survival rate when summation of external midline dose plus point A or point R dose by ICR was greater than 70-75 Gy. Conclusion : The definitive radiation therapy using high dose rate ICR in FIGO stage IB uterine cervical cancer is effective treatment modality with good local control and survival rate without severe complication.

  • PDF

Comparative Quantitative Study of Surfactant Protein C mRNA by Filter Hybridization and Solution Hybridization in Rats (Filter Hybridization과 Solution Hybridization 방법에 의한 백서 Surfactant Protein C mRNA 정량측정의 비교)

  • Kim, Jin-Ho;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.517-529
    • /
    • 2001
  • Background : Surfactant protein C(SP-C) is a hydrophobic 5,000 dalton molecule. SP-C has the primary roles in accelerating surface spreading of a surfactant phospholipid. The filter hybridization and solution hybridization assays are both rapid and sensitive and can be used to measure the RNAs complementary to any cloned DNA sequence. Methods : The authors measured the SP-C mRNA levels quantitatively using solution hybridization and filter hybridization assays to obtain a standard curve equation to quantify the mRNA of unknown samples comparatively. Results : 1. The minimum level of the specimens by solution hybridization was 3 pg for SP-C mRNA. 2. The standard curve equation of the solution hybridization assay between the counts per minute(Y) and the SP-C mRNA transcript input(X) was Y=6.46 X+244. The correlation coefficient was 0.99. 3. The minimum detection level of specimens by filter hybridization was 0.1 ng for SP-C mRNA. 4. The standard curve equation of the filter hybridization assay between the counts per minute(Y) and SP-C mRNA transcript input(X) is Y=2541.6 X+252.7. The correlation coefficient was 0.99. Conclusions : A comparison of CPM/filter in the linear range allowed an accurate and reproducible estimation of the SP-C mRNA copy number. Filter hybridization and solution hybridization assays are both rapid and sensitive and can be used to measure the RNAs complementary to any cloned DNA sequence. It is ideally suited to situations where accurate quantitation of multiple samples is required.

  • PDF

THE COMPARISON OF DIFFERENT CANAL IRRIGATION METHODS TO PREVENT REACTION PRECIPITATE BETWEEN SODIUM HYPOCHLORITE AND CHLORHEXIDINE (차아염소산나트륨과 클로르헥시딘의 반응침전물 형성방지를 위한 여러 가지 근관세척 방법의 비교)

  • Choi, Moon-Sun;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.80-87
    • /
    • 2010
  • The purpose of this study was to compare the different canal irrigation methods to prevent the formation of precipitate between sodium hypochlorite (NaOCl) and chlorhexidine (CHX). Extracted 50 human single-rooted teeth were used. The root canals were instrumented using NiTi rotary file (Profile .04/#40) with 2.5% NaOCl and 17% EDTA as irrigants. Teeth were randomly divided into four experimental groups and one control group as follows; Control group: 2.5% NaOCl only, Group 1: 2.5% NaOCl + 2% CHX, Group 2: 2.5% NaOCl + paper points + 2% CHX, Group 3: 2.5% NaOCl + preparation with one large sized-file + 2% CHX, Group 4: 2.5% NaOCl +95% alcohol+ 2% CHX. The teeth were split in bucco-lingual aspect and the specimens were observed using Field Emission Scanning Electron Microscope. The percentages of remaining debris and patent dentinal tubules were determined. Statistical analysis was performed with one-way analysis of variance (ANOVA). Energy Dispersive x-ray Spectroscopy was used for analyzing the occluded materials in dentinal tubule for elementary analysis. There were no significant differences in percentage of remaining debris and patent tubules between all experimental groups at all levels (p > .05). In elementary analysis, the most occluded materials in dentinal tubule were dentin debris. NaOCl/CHX precipitate was detected in one tooth specimen of Group 1. In conclusion, there were no significant precipitate on root canal, but suspected material was detected on Group 1. The irrigation system used in this study could be prevent the precipitate formation.

A Study of Adjustment for Beginning & Ending Points of Climbing Lanes (오르막차로 시.종점 위치의 보정에 관한 연구)

  • 김상윤;오흥운
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.5 s.91
    • /
    • pp.35-44
    • /
    • 2006
  • Acceleration and deceleration curves have been used for design purposes worldwide. The curve in design level has been regarded as an single deterministic curve to be used for design of climb lanes. It should be noted that the curve was originally made using ideal driving truck and that the curve is applied during design based on the assumption of no difference between ideal and real driving conditions. However. observations show that aged vehicles and lazy behavioring drivers nay make lower performance of vehicles than the ideal performance. The present paper provides the results of truck speeds at climbing lanes then probabilistic variation of acceleration and deceleration corves. For these purposes. a study about identification of vehicle makers, and weights for trucks at freeway toll gates and then observation of vehicle-following speed were performed. The 85%ile results obtained were compared with the deterministic performance curves of 180, 200, and 220 Ib/hp. It was identified that the performance of 85%ile results obtained from vehicle-following-speed observations were lower than one from deterministic performance curves. From these results, it may be concluded that at the beginning Point of climbing lanes additional $16.19{\sim}67.94m$ is necessary and that at the end point of climbing lanes $53.12{\sim}103.24m$ of extension is necessary.

Radiation-Induced Proctitis in Rat and Role of Nitric Oxide (백서모델에서 방사선 직장염 유발인자로서의 Nitric oxide의 역할)

  • Chun Mison;Kang Seunghee;Jin Yoon-Mi;Oh Young-Taek;Kil Hoon-Jong;Oh Tae-Young;Ahn Byoung-Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.265-274
    • /
    • 2001
  • Purpose : Proctitis is one of acute complications encountered when radiotherapy was appled to the pelvis. Radiation-induced proctitis represents similar microscopic findings that are observed in inflammatory bowel disease (IBD). Nitric oxide (NO) plays an important role in the inflammatory process and many data suggest a close relationship between NO production and gastrointestinal inflammation. This study was aimed to establish the optimal radiation dose for radiation-induced proctitis in rat and to find a relationship between radiation proctitis and NO production. Materials and methods : Female Wistar rats, weighing from 150 to 220 g, received various doses(10-30 Gy) of radiation to the rectum. On the 5th and 10th day after irradiation, rectal specimens were evaluated grossly and microscopically. In addition, the degree of NO production by irradiation dose was evaluated by study with NOS expression and nitrite production in the irradiated rectal tissue. To evaluate relationship between radiation proctitis and NO, we administered aminoguanidine, iNOS inhibitor and L-arginine, substrate of NOS to rats from 2 days before to 7 days after the irradiation. Results : There were obvious gross and hostological changes after 17.5 Gy or higher radiation dose but not with 15 Gy or less radiation dose. Twenty Gy or higher dose of radiation caused Grade 4 damage in most of rectal specimens which were more likely to be related to the late complications such as fibrosis, rectal bleeding and rectal obstruction. A single fraction of 17.5 Gy to the rat rectum is considered to be an optimal dose to produce commonly experienced proctitis in the clinic. The result demonstrated that severity of microscopic damage of rectal mucosa from irradiation significantly correlated with iNOS over-expression. However, administration of iNOS inhibitor or substrate of iNOS did not influence the degree of rectal damage. Conclusion : A single fraction of 17.5 Gy irradiation to the rat rectum considered to be an optimal dose for radiation induced proctitis model. These results indicated that an excess production of NO contributes to pathogenesis of radiation-induced proctitis in part but was not the direct cause of rectal damage.

  • PDF

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

GMI Microwave Sea Surface Temperature Validation and Environmental Factors in the Seas around Korean Peninsula (한반도 주변해 GMI 마이크로파 해수면온도 검증과 환경적 요인)

  • Kim, Hee-Young;Park, Kyung-Ae;Kwak, Byeong-Dae;Joo, Hui-Tae;Lee, Joon-Soo
    • Journal of the Korean earth science society
    • /
    • v.43 no.5
    • /
    • pp.604-617
    • /
    • 2022
  • Sea surface temperature (SST) is a key variable that can be used to understand ocean-atmosphere phenomena and predict climate change. Satellite microwave remote sensing enables the measurement of SST despite the presence of clouds and precipitation in the sensor path. Therefore, considering the high utilization of microwave SST, it is necessary to continuously verify its accuracy and analyze its error characteristics. In this study, the validation of the microwave global precision measurement (GPM)/GPM microwave imager (GMI) SST around the Northwest Pacific and Korean Peninsula was conducted using surface drifter temperature data for approximately eight years from March 2014 to December 2021. The GMI SST showed a bias of 0.09K and an average root mean square error of 0.97K compared to the actual SST, which was slightly higher than that observed in previous studies. In addition, the error characteristics of the GMI SST were related to environmental factors, such as latitude, distance from the coast, sea wind, and water vapor volume. Errors tended to increase in areas close to coastal areas within 300 km of land and in high-latitude areas. In addition, relatively high errors were found in the range of weak wind speeds (<6 m s-1) during the day and strong wind speeds (>10 m s-1) at night. Atmospheric water vapor contributed to high SST differences in very low ranges of <30 mm and in very high ranges of >60 mm. These errors are consistent with those observed in previous studies, in which GMI data were less accurate at low SST and were estimated to be due to differences in land and ocean radiation, wind-induced changes in sea surface roughness, and absorption of water vapor into the microwave atmosphere. These results suggest that the characteristics of the GMI SST differences should be clarified for more extensive use of microwave satellite SST calculations in the seas around the Korean Peninsula, including a part of the Northwest Pacific.

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.