• Title/Summary/Keyword: 발전성능계수

Search Result 155, Processing Time 0.024 seconds

Performance analysis simulation for domestic application of heat pump by using sea water heat source (해수열에너지를 이용한 히트펌프의 국내 적용을 위한 성능평가 시뮬레이션)

  • Lim, Seungtaek;Kim, Jungsik;Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.814-820
    • /
    • 2014
  • Due to the development of human civilization, industrialization and urbanization, the human race demanded the food, clothing and shelter as well as a comfortable living environment. For the purpose of this, the refrigeration and air conditioning part was carried out research and development. However, high oil prices and environmental pollution having problems in the 21st century cannot be overlooked. As an alternative, thermal system was designed using the heat pump to applied sea water heat source. In this paper, outside and sea temperatures are analysed in 2010 and carried out the performance analysis simulation at All water and All Air heat pump system by HYSYS program for domestic use. As a result, total average COP of the system is 3.37 from All Water system and All Air is 3.48. It showed that high performance confirmed in both system.

Fundamental Heat Analysis about the Thermoelectric Generation System Using the Waste Heat of Exhaust Gas from Ship (선박의 배기가스 폐열을 활용한 열전발전시스템에 관한 기초 열해석)

  • Kim, Myoung-Jun;Ga, Gwang-Jin;Chea, Gyu-Hoon;Kim, In-Seup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.583-592
    • /
    • 2016
  • IMO (International Maritime Organization) in the UN (United Nations) set up that aim at reducing $CO_2$ emission from ship by up to 30 percent until 2030. The final purpose of this study is the development of marine thermoelectric generation system using waste heat from vessel of internal combustion engines. Before the development of marine thermoelectric generation system, this paper carried out the fundamental heat analysis of marine thermoelectric generation system. It was able to obtain the valuable results about the efficiency improvement of the thermoelectric generation system. The results is as follows : 1) It was confirmed that the efficiency of thermoelectric generation system improves to 8.917 % with increasing the temperature difference of peltier module by reducing the temperature difference between peltier module and heat source at the hot side. 2) System efficiency according to change in the external load resistance was confirmed that the change width of about 6 % which does not significantly occur. 3) System efficiency in the case stainless steel at the same condition is 8.707 %. System efficiency could be confirmed that the stainless steel is higher than duralumin (8.605 %), copper (8.607 %).

Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings (주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가)

  • Kim, Deok-Sung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

Analysis of Performance of Balcony Integrated PV System (발코니 일체형 태양광발전시스템의 발전성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;So, Jung-Hoon;Yu, Gwon-Jong;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 2009
  • Photovoltaic(PV) permits the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of building integrated balcony PV system and analyzed both performance and problems of this system. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 74.7%.

Self-Starting Characteristics of Blades for Vertical Axis Wind turbine (수직축 풍력발전용 날개의 기동력특성)

  • Kim, Sung-Hoon;Kim, Young-Ik;Lee, Joon-Min
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • A study has been done for self-starting torque of vertical axis wind turbine blade. It is especially concentrated to evaluate the torque coefficient before starting rotation. Two different aerofoils(AMI903 and AMI904) are proposed to benchmark the possible best blade(supercritical airfoil) for self-starting performance. Torque coefficients in the tangential direction of rotation are given with respect to the angle of attack in terms of drag coefficient and lift coefficient. Torque coefficient shows that the effect of Reynolds number is minimal. The thicker blade(AMI904) between two different proposed airfoils has bigger torque coefficient, which is attributed to lower lift coefficient and higher drag coefficient.

Performance Comparison of Crawling Robots Trained by Reinforcement Learning Methods (강화학습에 의해 학습된 기는 로봇의 성능 비교)

  • Park, Ju-Yeong;Jeong, Gyu-Baek;Mun, Yeong-Jun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.33-36
    • /
    • 2007
  • 최근에 인공지능 분야에서는, 국내외적으로 강화학습(reinforcement learning)에 관한 관심이 크게 증폭되고 있다. 강화학습의 최근 경향을 살펴보면, 크게 가치함수를 직접 활용하는 방법(value function-based methods), 제어 전략에 대한 탐색을 활용하는 방법(policy search methods), 그리고 액터-크리틱 방법(actor-critic methods)의 세가지 방향으로 발전하고 있음을 알 수 있다. 본 논문에서는 이중 세 번째 부류인 액터-크리틱 방법 중 NAC(natural actor-critic) 기법의 한 종류인 RLS-NAC(recursive least-squares based natural actor-critic) 알고리즘을 다양한 트레이스 감쇠계수를 사용하여 연속제어입력(real-valued control inputs)으로 제어되는 Kimura의 기는 로봇에 대해 적용해보고, 그 성능을 기존의 SGA(stochastic gradient ascent) 알고리즘을 이용하여 학습한 경우와 비교해보도록 한다.

  • PDF

월성 2,3,4호기 비상급수계통 성능평가에 관한 연구

  • 오광석;김창호;이중섭;김선철;오종필
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.362-367
    • /
    • 1996
  • CANDU-6형 원자력발전소인 월성 2,3,4호기 비상급수계통의 성능을 평가하기 위하여 설계기능 수행과 관련된 변수로서 격납건물내 집수조(sump) 온도와 열수송계통으로 주입되는 냉각재온도를 사용한 분석을 수행하였다. 이 온도들은 NTU(Number of Transfer Unit)방법을 이용한 비상노심 냉각계통 열교환기의 열전달속도와 열전달계수의 해석을 열평형관계식과 함께 조합한 프로그램을 사용하여 계산하였다. 또한 증기발생기 급수량과 추후 수조에 공급되는 보충수에 대한 설계요건을 검토하였다. 이러한 변수와 설계요건은 비상급수계통이 발전소 정상 열제거기능 상실후 노심의 붕괴열제거에 유효한 열침원으로서의 기능을 수행함을 보여 주었다. 또 격납건물의 건전성 유지와 관련된 집수조내 최고온도가 허용치 이하로 유지되었다.

  • PDF

A Live Multimedia Multiplexing Method for VBR-coded Elementary Streams with Delay Constraints (지연 조건을 갖는 VBR 부호화된 기본 스트림에 대한 라이브 멀티미디어 서비스 다중화 기법)

  • 김진수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.9A
    • /
    • pp.1516-1524
    • /
    • 2001
  • 현재 ATM망, giga-bit 이더넷, fast 이더넷 그리고 프레임-릴레이와 같은 고속 전송 망 구축 기술이 발전함에 따라 다양한 소비자 욕구를 촉진시키고 있다. 특히, 다양한 멀티미디어 서비스의 환경에서는 다중화되는 개개의 기본 스트림들에 대한 특성이 더욱 가변적임에 따라, 이를 효과적으로 다중화하여 망에 적응 및 연동시키는 기술은 필수적이다. 본 논문에서는 이와 같은 응용 환경을 고려하여 가변 비트율로 부호화 및 다중화하여 전송되는 과정에 있어서 지나친 전송 대역폭의 낭비를 초래하지 않고 다중화 전송 기법을 제안한다. 가변 비트율로 부호화된 기본 스트림의 각 액세스 단위에 대해 부과되는 지연 크기에 의한 제한 조건 관계식을 정의하고, 이것을 바탕으로 라이브 멀티미디어 서비스를 제공하는 효과적인 두 가지 방안을 제안한다. 제안한 방법은 각각 시간적 측면만을 고려한 방법과 시간/공간적 측면을 동시에 고려한 방법으로 나누어 제안한다. 부호화된 Star-wars 데이터 트레이스를 이용한 모의 실험에서 제안된 방식은 크게 다중화 전송 스트림의 첨두율, 변화율 계수 그리고 유효 대역폭 측면에서 성능을 크게 개선시킴을 확인한다. 그리고, 저 지연을 갖는 멀티미디어 서비스에 대해 상대적으로 우수한 성능이 나타남을 확인한다.

  • PDF

Calculation of CO2 Emission w.r.t. Instantaneous Generator Output using Input-output Coefficients of Thermal Power Plant (화력발전소 입출력 특성계수를 이용한 순시 발전출력 대비 CO2 대기배출량 계산)

  • Lee, Sang-Joong;Lim, Jeong-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.120-125
    • /
    • 2007
  • Burning the fossil fuel in the thermal power plants causes green house gas emission. Monitoring of CO2 emission of the thermal power plants is growing more important because the amount produced by them is more than 20 percent of national total emission. This paper proposes a method to calculate the amount of the CO2 emission w.r.t. generator[MW] output using the input-output coefficients of the thermal power plants. The power flow computation together with the CO2 emission calculation are demonstrated in a sample power system.

No-Reference Image Quality Assessment Using Complex Characteristics of Shearlet Transform (쉬어렛 변환의 복소수 특성을 이용하는 무참조 영상 화질 평가)

  • Mahmoudpour, Saeed;Kim, Manbae
    • Journal of Broadcast Engineering
    • /
    • v.21 no.3
    • /
    • pp.380-390
    • /
    • 2016
  • The field of Image Quality Measure (IQM) is growing rapidly in recent years. In particular, there was a significant progress in No-Reference (NR) IQM methods. In this paper, a general-purpose NR IQM algorithm is proposed based on the statistical characteristics of natural images in shearlet domain. The method utilizes a set of distortion-sensitive features extracted from statistical properties of shearlet coefficients. A complex version of the shearlet transform is employed to take advantage of phase and amplitude features in quality estimation. Furthermore, since shearlet transform can analyze the images at multiple scales, the effect of distortion on across-scale dependencies of shearlet coefficients is explored for feature extraction. For quality prediction, the features are used to train image classification and quality prediction models using a Support Vector Machine (SVM). The experimental results show that the proposed NR IQM is highly correlated with human subjective assessment and outperforms several Full-Reference (FR) and state-of-art NR IQMs.