• Title/Summary/Keyword: 발열 특성

Search Result 1,073, Processing Time 0.03 seconds

A Study on Design Method depending upon Low Carbon Green Architecture of Big Medical Center (대형의료기관 건축물에 대한 저탄소 녹색 친환경 설계 방안에 관한 연구)

  • Kim, Jong Gu;Park, Jong Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.987-996
    • /
    • 2015
  • According to the recent research results of the Ministry of Environment, the indoor air quality of large general hospitals and university hospitals(58 hospitals) exceeded the maintenance standard. On top of such indoor air quality, it is also desperately required to have the environment-friendly building design and also low carbon green design in accordance with the increase of hospital size and enlarged hospital buildings. Especially, the increase of carbon dioxide, heat, garbage, waste energy, exhaust heat from power plants and sewage heat in each medical center brings up lots of problems to the health of hospital patients and customers. Thus this study aims to convergently develop the green environment-friendly architecture design technology concerning the organic relations between each medical building, and technical development which should be introduced to the low carbon green environment-friendly architecture design based on the characteristics of each medical center in large-scale medical complex.

A study on the Temperature Control of Insulated Open-End Water Vessel (밑이 트인 단열수조의 온도제어에 관한 연구)

  • Han, Seung-Hun;Bae, Cherl-O;Ahn, Byong-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1097-1103
    • /
    • 2012
  • There are many fish farms being cultivated in the southwestern cost of South Korea. Because the farms cultivating use the basic method that inflow and circulate sea-water, slight negligence and bad design cause major negative impact on fish deaths. Also, the optimal temperature for each specie of fishes has already been proven to differ on each specie. Maintaining this environment, regardless of seasons, is very difficult and that requires research to develop. In this paper, basic characteristics of heat and mechanism of heat transfer are studied. Based on this, Open-end water vessel is designed and constructed using sandwich-insulation panels and simulated to store the heat in certain isolated space. This study confirmed that it is possible to keep constant temperature by this method, in large areas of water where it is insulated by heat insulator. and equipped with heater in Open-end water vessel where the other part is heated. The AC power controller maintains the constant temperature required and the temperature controller detects and displays the temperature by using the micro-processor.

Thermal Stability and Deintercalation of K-synthetic Graphite Intercalation Compounds at Elevated Temperatures (칼륨-인조 흑연 층간 화합물의 고온열적 안정성과 Deintercalation)

  • Oh, Won-Chun;Lee, Young-Hoon;Ko, Young-Shin
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.92-95
    • /
    • 1998
  • K-SGICs(synthetic graphite intercalation compounds) were synthesized in a modified two-bulb pyrex tube. The pressure in the two-bulb tube was maintained at approximately $10^{-3}$ torr for the reaction of potassium and graphite. Deintercalation process of the K-SGlCs obtained by the modified method was heat-treated by keeping in liquid paraffin between $25^{\circ}C$ and $1400^{\circ}C$. The thermal stability and the temperature dependence of the K-SGICs were characterized using differential scanning calorimeter(DSC) analyzer. Enthalpy and entropy for K-SGIC formations were calculated by confirming the deintercalation and thermodynamic exothermic reactions depending on the various temperatures. The structure changes and thermal stability of K-SGICs during the deintercalation reaction of potassium ions and the interlayer spaces of the synthetic graphite were identified by X-ray diffraction(XRD).

  • PDF

A Study on Noxious Gases Analysis of Polyurethane foams (Polyurethane foam의 유해가스 분석에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.7-13
    • /
    • 2000
  • We had investigated thermal stability, Ignition temperature and fire gas for polyurethane foams used for manikin, cushion and interior finishing material. Decomposition of polyurethane foams with temperature was investigated using a DSC and the weight loss with temperature increase using a TGA in order to find the thermal hazard of polyurethane foams, and the ignition temperature of polyurethane foams according to species. We studied constant temperature among ignition temperature measuring methods. In addition, noxious gases for polyurethane foams according to combustion condition were analyzed using gas analyzer and GASTEC. As results, initial decomposition temperature of polyurethane foam used for interior finishing material was lower than those for manikin and cushion, and exothermic energy was higher. Ignition temperature of polyurethane foam of interior finishing material was $420^{\circ}$. All of combustion forms at $427^{\circ}$ and under were smoldering combustion, and it was combustion at $500^{\circ}$. As furnace temperature was increased, concentration of noxious gases such as carbon oxide, carbon dioxide, and hydrogen cyanide was increased. And nitrogen oxide at combustion condition($500^{\circ}$) was over 10 ppm.

  • PDF

Determination of Optimum Reaction Conditions for Pyrolytic Coprocessing of Waste Plastics with Waste Motor oil by Statistical Experimental Design (통계적 실험계획에 의한 폐플라스틱/폐유의 최적 열분해 반응조건 결정)

  • Yoon, Wang-Lai;Park, Jong-Soo;Jung, Heon;Lee, Ho-Tae;Ko, Sung-Hyuk;Kim, Sung-Hyun
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.189-201
    • /
    • 1999
  • 범용 열가소성 플라스틱(polyethylene(PE), polypropylene(PP), polystyrene(PS), polyethylene-terephthalate(PET), acrylonitrile-butandiene-styrene(ABS))과 폐윤활유의 동시처리 열분해반응 실험을 수행하였다. 반응실험은 40$m\ell$ 용량의 회분식 미분반응기(microreactor)를 이용한 실험과 1리터 용량의 autoclave를 이용한 실험의 두 가지로 구분하여 행하였다. 전자의 경우는 통계적 실험적계획법(statistical experimental design)의 하나인 회전계획실험(rotatable design experiments)으로서 오각형 실험계획(pentagonal experimental design)에 의거한 반응변수 실험을 수행한 후 반응표면(response surface)을 회기분석법에 의하여 분석함으로써 최대의 오일 수율을 얻을 수 있는 최적 반응조건을 추적, 결정하였다. Autoclave 반응실험의 기본적인 목적은 실제 연속공정에 있어서 열분해 반응기 거동을 모사하기 위한 전초단계로서 충분한 시료의 확보를 통하여 이 때 생성된 연로유의 체계적인 분석(비등점분포특성, 진공증류, 기체분석, 원소분석, 발열량, 비중 등)을 행함으로써 연료유 수율 및 품질을 모사하고자 하였다. 미분반응기 실험에 있어서 주 범용열가소성수지인 PE, PP 그리고 PS는 각각의 최적반응조건하에서 거의 100%에 가깝게 오일로 전환되었지만 응축수지인 PET와 그래프트공중합수지인 ABS의 오일수율은 각기 78% 및 90%로서 상대적으로 낮게 나타났다. Autoclave를 이용한 실험의 경우 혼합플라스틱을 폐유에 대하여 40wt% 혼합하여 열분해하였을 때, 80wt% 오일, 15wt% 코우크, 그리고 나머지 5wt%는 탄화수소기체(C1-C6)로 전환되었다. 진공증류(252$^{\circ}C$,2 torr) 결과, 기/액-분리도는 3으로서 이는 생성오일의 75wt%가 경질연료유(가솔린, 등유, 경유)로 회수 가능하였다.

  • PDF

A Study on Spontaneous Ignition Temperature and Activation Energy of Hydroxypropyl Methyl Cellulose (Hydroxypropyl Methyl Cellulose의 자연발화온도와 활성화 에너지에 관한 연구)

  • Lim, Woo-Sub;Choi, Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.5
    • /
    • pp.77-83
    • /
    • 2007
  • This study is conducted on spontaneous ignition temperature and activation energy of Hydroxypropyl Methyl Cellulose(HMC) powder. HMC is a kind of cellulose derivative and used as additives for building material, surface coating, printing ink, adhesives, cosmetics and medical supplies. So this material has been widely used as important additive in the chemical industry fields and a mount of production has increased year by year. Therefore, it is very important to find out the thermal ignition characteristics of its danger and the critical ignition temperature. This study was performed by the Spontaneous Ignition Tester(SIT) and so on. Based on the data of the SIT-II, the critical ignition point of HMC is about $186^{\circ}C$ which is slightly lower than normal cellulose.

Thermo-Chemical Conversion Characteristics of Wood wastes in a Fixed micro-reactor (고정층 마이크로 반응기에서의 폐목재 열화학적 전환 특성)

  • Lee In-Gu;Lee Jae-Goo;Kim Jae-Ho;Lee See-Hoon
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.66-73
    • /
    • 2006
  • The effects of operation conditions, such as bed temperature, temperature rising rate, particle size, moisture content and so on, on thermo-chemical conversion of waste wood have been determined in a micro fixed bed gasifier. The samples were waste wood-chips such as pine, oak, acacia and ginkgo. The thinning timbers used as reactants in the experiments had $35wt\%$ moisture content, $0.5wt\%$ ash content and 4,550 kcal/kg heating value on a dry basis. A typical product distribution was a $40wt\%$ liquid, $20wt\%$ solid, and $40wt\%$ dry syngas. The syngas concentration was affected by operation conditions and average syngas concentration was $H_2:40vol\%,\;CO:30vol\%,\;CH_4:10vol\%$.

A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents (단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.

Study on Thermal Pattern and Current Characteristics of an LED Street Lamp (LED 가로등의 발열 패턴 및 전류 특성에 관한 연구)

  • Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.357-361
    • /
    • 2009
  • This study performed analysis on the thermal pattern and current characteristics of an LED ((Light Emitting Diode) street lamp. It did this using a TVS (Thermal Video System) to analyze the LED street lamp's thermal pattern, and measured its characteristics using an oscilloscope. The ambient temperature and humidity during the experiment were maintained at $24{\pm}2[^{\circ}C]$ and 50~60[%]. The capacity of the LED street lamp was 120[W] and nine sets of modules were arranged at uniform intervals. On one module, 24 LED lamps were arranged in a radial pattern. The analysis of the thermal diffusion pattern at the front of the LED lamp showed that the maximum surface temperature was approximately $34[^{\circ}C]$. In addition, there was almost no change in the temperature of the upper cover, and the temperature at the side showed a uniform thermal diffusion pattern. The surface temperature of the converter converting AC to DC increased to approximately $46[^{\circ}C]$. The analysis results of the thermal characteristics of one LED indicated uniform thermal characteristics for an initial eight minutes. However, the temperature at the center of the LED increased to approximately $82[^{\circ}C]$ after 12 minutes had elapsed. It can be seen from this that the temperature at the center of the LED was higher than the allowable temperature, $70[^{\circ}C]$ of the insulating material for general electrical devices. Therefore, it is necessary to design a lamp in such a way that the plastic insulating material does not come into contact with or get close to the LED lamp. The voltage of the LED lamp converted by the AC/DC converter was measured at DC 27[V] and the current was DC 13[A]. Consequently, it can be seen that in order to secure an adequate light source, it is important to supply a stable current that was greater than the current of other light sources. Therefore, appropriate radiation of heat is required to secure the stability and reliability of the system.

A Study on Cogeneration System Using 5ton/day Scale Downdraft Waste Wood Gasifier (5톤/일 하향류식 가스화기를 이용한 폐목재 가스화 열병합 발전기술 연구)

  • Yoon, SangJun;Kim, YongKu;Lee, JaeGoo;Kim, KiSe;Kang, ByungChan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.174.2-174.2
    • /
    • 2011
  • 최근 유가상승과 석유, 천연가스의 가채 매장량의 한계등과 함께 온실가스에 의한 지구온난화 방지를 위하여 미국, 유럽국가 및 캐나다 등에서는 바이오매스를 이용한 에너지 회수 기술개발에 많은 관심과 연구를 수행하고 있다. 바이오 매스는 에너지 밀도 대비 존재하는 지역이 광범위하여 발생, 수집, 수송에 따른 비용이 많이 소요되는 특성이 있어 산지에서 직접처리하거나 수집하여 대규모처리등과 같이 여러 가지 현장상황에 따라 적정한 플랜트 운용의 유연성을 갖추고 있어야 한다. 일반적으로 바이오매스로부터 중소형으로 분산형 발전이나 수소제조를 위해서는 직접 연소법 보다는 가스화 방식을 이용하고 있는데, 연소에 의해 열을 생산하여 전기를 생산하는 방식은 스팀터빈을 이용하는 것이며, 스팀터빈은 소형 운용이 어렵기 때문이다. 본 연구에서는 폐목재로부터 합성가스제조를 위하여 5톤/일 규모 가스화기를 제작하였으며, 타르 및 수트와 같은 미반응 물질을 제거할 수 있는 집진, 세정장치를 설계 및 제작하였다. 또한 합성가스에 함유된 현열로부터 열회수를 위하여 열교환기를 설치하였으며, 정제된 합성가스를 이용하는 가스엔진을 통하여 열병합 발전시스템 연계운전을 수행하였다. 운전 실험을 폐목재 가스화 3톤/일 규모로 수행하였으며, 평균 1,500kcal/$Nm^3$의 발열량을 갖는 합성가스를 생성시킬 수 있었다. 사이클론, 스크러버 및 기수분리 장치를 이용하여 정제된 합성가스는 합성가스 엔진을 통하여 72kW 이상의 전력생산이 가능하였다. 열교환기를 통하여 평균 15,000kcal/h의 배열 회수가 가능하였으며, 바이오매스 가스화 합성가스를 이용한 열병합 발전이 가능함을 입증하였다.

  • PDF