Accuracy of Temperature Measurements, Nursing Time for Measuring Temperature and the Validity of Fever Detection (체온측정방법의 정확도와 간호시간 및 발열감별 타당도 비교)

  • Sohng Kyeong-Yae;Kang Sung-Sil;Hwang Jin-Soon;Kim Myung-Ja
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.33-45
    • /
    • 1998
  • The aim of this study was to investigate what is the most accurate and quick temperature measurement among rectal, auxiliary and tympanic routes. The body temperatures of 86 preform infants in incubators, a controlled environment, were measured at three different sites. The measurements were taken to examine the accuracy of the temperatures, proper nursing time for measuring the temperatures and the validity of fever detection. The results were as follows : 1. The mean temperature was significantly lower in the auxiliary site($36.71^{\circ}C$) and higher in the tympanic site($37.27^{\circ}C$) than in the rectal site($37.03^{\circ}C$). 2. The mean nursing time for measuring body temperature was significantly longer in the auxiliary site(171.65 seconds) and shorter in the tympanic site(17.70 seconds) than in the rectal site(83.33 seconds). 3. The nursing time for measuring body temperature included the time needed for preparation, measuring, as well as the post-measuring time. It was found that the time required to prepare for measuring the temperature of the rectal site was significantly longer than for other sites. In addition, the time needed to measure the temperature of the auxiliary site was significantly longer than in the other sites. Finally, the nursing time needed for measuring the auxiliary temperature(171.65 seconds) was the longest among the three sites whereas the nursing time for the tympanic site was the shortest(17.70 seconds). 4. Rectal temperature was significantly correlated to the tympanic(r=0.67) and auxiliary temperatures(r=0.69). Tympanic temperature was also significantly correlated to the auxiliary temperature(r=0.74). 5. The sensitivity, specificity, positive and negative predictive values of tympanic temperatures for detecting fever were 1.00, 0.80, 0.24, and 1.00, respectively. Those for the auxiliary temperatures were 0.00, 0.99, 0.00, and 0.94, respectively. Thus the level of fever detection was lower in the auxiliary temperatures than in tympanic temperatures. The above findings indicate that the tympanic method of temperature measurement offers a useful alternative to conventional methods.

  • PDF

Accuracy, Precision, and Validity of Fever Detection using Non-invasive Temperature Measurement in Adult Coronary Care Unit Patients with Pulmonary Catheters (폐동맥관을 부착하고 있는 심장수술 환자에 대한 비침습적 체온측정 방법의 정확도, 정밀도 및 발열감별 타당도)

  • Joo, Ga-Eul;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.424-433
    • /
    • 2012
  • Purpose: To investigate the accuracy, precision and validity of fever detection of tympanic membrane (TM), temporal artery (TA) and axillary temperature (AT) compared with pulmonary artery temperature (PA). Methods: Repeated-measures design was conducted for one year on 83 adult cardiac care unit patients with pulmonary artery catheters after open heart surgery. Sequential temperature measurements were taken three times at 20-minute intervals. Accuracy, precision, repeatability, and validity of fever detection were analyzed. Results: Mean pulmonary artery temperature was $37.04^{\circ}C$ (SD $0.70^{\circ}C$). The mean (SD) offsets from PA, with the mean reflecting accuracy and SD reflecting precision, were $-1.31^{\circ}C$ ($0.75^{\circ}C$) for TA, $-0.20^{\circ}C$ ($0.24^{\circ}C$) for TM, and $-0.97^{\circ}C$ ($0.64^{\circ}C$) for AT. Percentage of pairs with differences within ${\pm}0.5^{\circ}C$ was 9.6% for TA, 19.7% for AT, and 91.6% for TM. Repeated measurements with all three methods had mean SD values within $0.04^{\circ}C$. Sensitivity, specificity, and positive and negative predictive values of tympanic measurements were 0.76, 1.0, and 1.0, and 0.90, respectively. Conclusion: Results show that TM best reflects PA, and is most consistent, accurate, and precise. AT tends to underestimate PA, and TA is least accurate and precise. Therefore tympanic membrane measurement is a reliable alternative to other non-invasive methods of measuring temperatures.