• Title/Summary/Keyword: 발관

Search Result 29, Processing Time 0.03 seconds

Clinical Characteristics of Reintubated Patients After Planned Endotracheal Extubation (계획된 기관 내관 발관(extubation) 후 재 삽관(reintubation)한 환자의 임상적 특징)

  • Sohn, Jang Won;Shin, Sung Joon;Kim, Tae Hyung;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.439-442
    • /
    • 2004
  • Background : Extubation failure and reintubation increase the morbidity and the mortality rate. Several extubation criteria and risk factors for extubation failure have been recommended. However, some patients present with extubation failure even after a planned extubation. The aim of this study was to evaluate the clinical characteristics of patients with extubation failure after a planned extubation. Methods : Thirty one patients who presented with planned extubation were included. Extubation failure was defined as reintubation within 48 hours after extubation. The clinical, respiratory and hemodynamic parameters between extubation success and failure group were compared. Results : Six patients were included in the failure group. The extubation failure rate was 19.4%. The age, periods of intubation and heart rates were significantly different between the extubation success and failure group. In the success and failure group, the mean age were $60.4{\pm}15.65$ vs. $80.3{\pm}7.17$ year, the intubation periods were $7.12{\pm}2.47$ vs. $13.83{\pm}2.4$ day and the heart rates were $94.32{\pm}5.77$ vs. $110.67{\pm}3.78/min$, respectively. Conclusion : Old age and patients intubated for periods will require a will careful assessment before extubation. Extensive cardiac evaluations before extubation will also be needed.

Extubation Time by Birth Weight and the Predictors for Success/Failure at the First Extubation in Extremely Low Birth Weight Infants (초극소저출생체중아에서 출생체중별 발관시기 및 첫 발관 시의 성공/실패 예측인자)

  • Choi, Chang Won;Park, Sung Eun;Jeon, Ga Won;Yoo, Eun Jung;Hwang, Jong Hee;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.5
    • /
    • pp.488-494
    • /
    • 2005
  • Purpose : To outline the aspects of extubation by birth weight and find the predictors for success/failure at the first extubation in extremely low birth weight infants. Methods : One hundred thirteen extremely low birth weight infants(<1,000 g) who were admitted to NICU at Samsung Seoul Hospital between Jan. 2000 and Jun. 2004 were enrolled. Clinical characteristics that are thought to be related with extubation success or failure were compared with the success and the failure of the first extubation. Results : As the birth weight decreased, extubation success day was significantly delayed : $16{\pm}3day(d)$ in 900-999 g; $20{\pm}3d$ in 800-899 g; $35{\pm}4d$ in 700-799 g; $37{\pm}9d$ in 600-699 g; $49{\pm}12d$ in ${\leq}599g$. 25 out of 113 infants(22%) failed the first extubation. Preterm premature rupture of membrane was associated with extubation success, and air leak was associated with extubation failure, with a borderline significance. Postnatal and corrected age and body weight at the first extubation, nutritional status, and ventilator settings were not associated with extubation success or failure. Extubation success day was significantly delayed, and the incidence of late-onset sepsis and mortality was significant higher in the failure of the first extubation. Conclusion : We could not find significant predictors for success/failure at the first extubation. The failure of the first extubation had an increased risk of late-onset sepsis and death. Further studies are needed to find the predictors for extubation success/failure.

Study on an Unplanned Extubation Prevention Program (UEPP) for Intubated Patients in Intensive Care Unit (비계획적 발관 예방을 위한 교육프로그램 적용효과)

  • Kang, Kyung-Ja;Yu, Mi
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.331-338
    • /
    • 2014
  • Unplanned extubation prevention program (UEPP) was developed and applied to intubated patients hospitalized in a medical intensive care unit (ICU). The number of unplanned extubation was 29 during the preliminary investigation and 23 cases during the prevention intervention program. The general features of the patients and nurses who experienced UE did not have any significant differences between the two periods, with only the number of new nurses in the ICU being significantly different (p=.039). Although the number of new nursing staff in the ICU was high, the mean rate of unplanned extubation, which is the number of UE days per 1000 intubation days, was 8.8 during the prevention intervention program, which was significantly lower than 12.3, the mean rate of UE during the preliminary investigation (t=-2.333, p=.040). The results provide a prevention program that could contribute to the safety of patients by actively preventing unplanned extubation in intubated patients in ICU.

Risk Factors of Extubation Failure and Analysis of Cuff Leak Test as a Predictor for Postextubation Stridor (발관 실패의 위험 인자 및 발관 후 천음과 재삽관의 예측에 있어 Cuff Leak Test 의 유용성과 의미 분석)

  • Lim, Seong Yong;Suh, Gee Young;Kyung, Sun Yong;An, Chang Hyeok;Park, Jung Woong;Lee, Sang Pyo;Jeong, Sung Hwan;Ham, Hyoung Suk;Ahn, Young Mee;Lim, Si Young;Koh, Won Jung;Chung, Man Pyo;Kim, Ho Joong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • Background: Extubation failure was associated with poor prognosis and high hospital mortality. Cuff leak test (CLT) has been proposed as a relatively simple method for detecting laryngeal obstruction that predispose toward postextubation stridor (PES) and reintubation. We examined the risk factors of extubation failure and evaluated the usefulness and limitation of CLT for predicting PES and reintubation. Methods: Thirty-four consecutive patients intubated more than 24 hours were examined. The subjects were evaluated daily for extubation readiness, and CLT was performed prior to extubation. Several parameters in the extubation success and failure group were compared. The accuracy and limitation of CLT were evaluated after choosing the thresholds values of the cuff leak volume (CLV) and percentage (CLP). Results: Of the 34 patients studied, 6 (17.6%) developed extubation failure and 3 (8.8%) were accompanied by PES. The patients who had extubation failure were more likely to have a longer duration of intubation and more severe illness. The patients who developed PES had a smaller cuff leak than the others: according to the CLV ($22.5{\pm}23.8$ vs $233.3{\pm}147.1ml$, p=0.020) or CLP ($6.2{\pm}7.3$ vs $44.3{\pm}24.7%$, p=0.013). The best cut off values for the CLV and CLP were 50ml and 14.7%, respectively. The sensitivity, negative predictive value, and specificity of CLT were relatively high, but the positive predictive value was low. Conclusion: The likelihood of developing extubation failure increases with increasing severity of illness and duration of intubation. A low CLV or CLP (<50ml or 14.7%) is useful in identifying patients at risk of PES, but the CLT is not an absolute predictor and should not be used an indicator for delaying extubation.

Comparison of Related Characteristics between Unplanned and Planned Extubation of Patients in Medical Intensive Unit (내과계 중환자의 비계획적 기관내관 발관과 계획적 기관내관 발관의 관련 특성 비교)

  • Cho, Hyo Im;Lee, Young Whee;Kim, Hwa Soon;Sim, Bo-Yun
    • Korean Journal of Adult Nursing
    • /
    • v.24 no.5
    • /
    • pp.509-519
    • /
    • 2012
  • Purpose: This retrospective study was designed to examine the frequency of unplanned extubation, and to identify the related factors of unplanned extubation in medical intensive care unit patients. Methods: Data were collected from medical records of patients who received intubation in a medical intensive care unit. One hundred eighteen patient charts were selected for the study. The Patient Severity Classification Scale and unplanned extubation risk factors were examined. Data were analyzed with descriptive statistics, $x^2$-test, Fisher's exact test and Mann-Whitney U test. Results: The incidence of unplanned extubation was 11 (9.32%) out of 118 patients who had undergone intubation. There were statistically significant differences between the unplanned extubation and work shift ($x^2$=61.52, p=.001), ventilation mode (p=.001), number of days of ventilator application (U=366.00, p=.038) and administration of sedatives (p=.025). Conclusion: Unplanned extubation is affected by the following variables: a) whether a nurse is in night shift, b) whether ventilation is mandatory, c) duration of ventilation use and d) administration of sedatives.

Post-extubation Negative Pressure Pulmonary Edema Complicating Partial Rib Resection -A case report- (늑골 절제술 환자에서 기관 내 튜브 발관 후 발생한 음압성 폐부종 -1예 보고-)

  • Kim, Jae-Jun;Jo, Min-Seop;Cho, Kyu-Do;Park, Yeon-Jin;Kim, Yong-Shin;Cho, Deog-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.313-316
    • /
    • 2007
  • Negative pressure pulmonary edema (NPPE) during anesthetic recovery is a rare, but potentially serious complication for patients who are undergoing different surgical procedures. The proposed mechanism is the generation of high negative pressure during markedly respiratory effort and upper airway obstruction from glottis closure and laryngospasm, and this all leads to pulmonary edema. We report here on a case of a healthy 26-year-old male who immediately developed NPPE and hemoptysis following extubation after partial rib resection due to benign rib tumor; the patient was treated conservatively. We also include a review of the review literatures.

Effects of Rotated Endotracheal Tube Fixation Method on Unplanned Extubation, Oral Mucosa and Facial Skin Integrity in ICU Patients (기관내관 순환고정방법이 중환자실 환자의 비계획적 발관 및 구강.안면 피부 통합성에 미치는 효과)

  • Choi, Young-Soon;Chae, Young-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.1
    • /
    • pp.116-124
    • /
    • 2012
  • Purpose: The study was done to compare effects of two endotracheal tube (ET tube) fixation methods (rotated fixation versus conventional) on unplanned extubation and skin integrity for orally intubated patients in intensive care units. Methods: The research design was a non-equivalent control group with repeated measures design. Participants were 80 patients; 40 participants assigned to each group. ET tube for the experimental participants fixed with rotated method every morning. Unplanned extubation was assessed by bedside nurses using the unplanned extubation report form. Oral mucosa and facial skin integrity were assessed using oral assessment guide and facial skin integrity assessment guide at day 3, 7, 10 and 14. Results: There was no difference in the unplanned extubation rate between the two groups. Oral mucosa impairment scores for the rotated fixation method were significantly lower at day 7 (p=.044), 10 (p=.048) and day 14 (p=.037). Also facial skin integrity impairment scores for the same group were significantly lower at day 7 (p=.010), 10 (p=.003), and 14 (p=.002). Conclusion: Results of the study suggest that the rotated fixation method is effective for these patients, to prevent impairment of oral mucosa and facial skin integrity. Further research is needed to prevent unplanned extubation.

Risk Factors for Deliberate Self-extubation (기관 내 삽관환자의 의도적 자가발관 위험요인)

  • Cho, Young Shin;Yeo, Jung Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.5
    • /
    • pp.573-580
    • /
    • 2014
  • Purpose: This study was conducted to analyze intubation survival rates according to characteristics and to identify the risk factors affecting deliberate self-extubation. Methods: Data were collected from patients' electronic medical reports from one hospital in B city. Participants were 450 patients with endotracheal intubation being treated in intensive care units. The collected data were analyzed using Kaplan-Meier estimation, Log rank test, and Cox's proportional hazards model. Results: Over 15 months thirty-two (7.1%) of the 450 intubation patients intentionally extubated themselves. The patients who had experienced high level of consciousness, agitation. use of sedative, application of restraints, and day and night shift had significantly lower intubation survival rates. Risk factors for deliberate self-extubation were age (60 years and over), unit (neurological intensive care), level of consciousness (higher), agitation, application of restraints, shift (night), and nurse-to-patient ratio (one nurse caring for two or more patients). Conclusion: Appropriate use of sedative drugs, effective treatment to reduce agitation, sufficient nurse-to-patient ratio, and no restraints for patients should be the focus to diminish the number of deliberate self-extubations.

A Case of Bacterial Tracheitis Associated with Endotracheal Intubation and Corticosteroid (기관내삽관과 스테로이드 사용 후 발생한 세균성 기관염 1예)

  • Lim, Jae-Min;Kim, Jung-Ho;Jung, Heon-Nyoung;Kim, Eun-Kyung;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.332-336
    • /
    • 2002
  • Bacterical tracheitis is a very rare complication in adults after endotracheal intubation. We report a case of bacterial tracheitis associated with endotracheal intubation and corticosteroids. The patient was discharged with a permanent tracheostomy, and a resection and an end-to-end anastomosis of the trachea is planned.

Effects on Unplanned Extubation, Oral Mucosa, and Facial Skin Integrity of New Method to Secure Endotracheal Tube (새로운 기관튜브 고정기구 적용이 비계획적 발관과 구강·안면 피부 통합성에 미치는 효과)

  • Kim, Jung Sook;Lee, Eun Sook;Park, Jin Hyang
    • Journal of Korean Clinical Nursing Research
    • /
    • v.15 no.3
    • /
    • pp.49-59
    • /
    • 2009
  • Purpose: Examination was done of the effects on unplanned extubation, oral mucosa, and facial skin integrity in patients with oral intubation secured with a new method using Multifix Endo II. Methods: A prospective quasai-experimental design was used. Data were collected during a 3-week EICU admission period between Jun. 1 and Nov. 30. Two hundreds seventeen (conventional taping group: 105, Multifix Endo II group: 112) orally intubated adults were enrolled in the study at the EICU of the C University Hospital. Results: The incidence of unplanned extubation (${\chi}^2=11.580$, p=0.03) and scores for the facial skin integrity impairment of the Mutifix Endo II group (t=5.28, p=.000) were significantly lower than those of the conventional taping group even though the scores for oral mucosa impairment were not different. The nurse's evaluation of the clinical effectiveness of the two methods including convenience, comfort, safety, and satisfaction were also higher for the new securement method compared to the conventional taping group. Conclusion: The securement method using Mutifix Endo II was more effective than the conventional method in the prevention of unplanned extubation and maintenance facial skin integrity.