• Title/Summary/Keyword: 반응유동

Search Result 935, Processing Time 0.028 seconds

A Study on the Drying and Carbonization of Sewage Sludge in Fluidized Bed Reactor (유동층 반응기에서 하수슬러지의 건조 및 탄화 특성에 관한 연구)

  • Choung, Young-Hean;Cho, Ki-Chul;Kang, Dong-Hyo;Kim, Yi-Kwang;Park, Chang-Woong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.746-751
    • /
    • 2006
  • In this study, drying and carbonization experiment was conducted in a fluidized bed reactor according to the variations in gas velocity, particle size, and reactor temperature. As a result, the weight loss rates of sludge by drying in the fixed bed and fluidized bed type dryer showed that drying in the fluidized bed was about 6 times faster than drying in the fixed bed, and the weight loss rates of sludge by carbonization in the fixed bed and fluidized bed type reactor showed that carbonization in the fluidized bed was about 4 times faster than drying in the fixed bed. This implies that carbonization in the fluidized bed was completed within 10 minutes. Although the amount of char decreased with the increase of carboniration temperature, the amount of char became similar at upper 873K. Also, the amount of char decreased with increasing gas velocity. Consequently, it could be efficient that slow fluidization should be maintained within the range of fluidization in case of fluidized carbonization of sewage sludge at 873K.

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF

The Removal of Toluene by a Granular Activated Carbon Bioreactor using Yeast (Yeast와 입상활성탄을 이용한 미생물반응기의 휘발성유기화합물 분해 특성)

  • NamGung, Hyeong-Kyu;Shin, Seung-Kyu;Ahmed, Zubair;Song, Ji-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1218-1224
    • /
    • 2008
  • A liquid culture of yeast "Candida tropicalis" was used in a fluidized bioreactor to achieve high removal efficiencies of volatile organic compounds (VOCs). In this study, granular activated carbon (GAC) was used as a fluidized material to improve adsorptive capacity as well as mass transfer of gaseous toluene, the model VOC. The GAC fluidized bioreactor demonstrated toluene removal efficiencies ranging from 50 to 80%, when inlet toluene loading varied in a range between 13.1 and 37.4 g/m$^3$-hr. The maximum elimination capacity determined in the GAC fluidized bioreactor was 172 g/m$^3$-hr at a toluene loading of 291 g/m$^3$-hr. Transient loading experiments revealed that the removal efficiency was remained unchanged during an increased loading period, and toluene introduced to the bioreactor was first absorbed to GAC and then slowly desorbed and became available to the yeast culture. Hence the fluidized GAC helped to achieve an improved mass transfer between the gas and liquid phases, resulting in high toluene removal capacity. Consequently, the GAC fluidized bioreactor using C. tropicalis can be successfully applied for the removal of VOCs, and is a feasible alternative over conventional processes such as packed-bed biofilters.

Photocatalytic degradation of Trichloroethylene with annulus fluidized bed photoreactor (애뉼러스 유동층 광반응기에서 Trichloroethylene의 광촉매 분해반응 특성)

  • 임탁형;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.215-218
    • /
    • 2002
  • 대기로 배출되는 휘발성 유기화합물 중의 하나인 TCE (Trichroloethylene)를 제거하는 기술들은 설치비 및 운전비가 많이 요구되는 흡착, 응축, 소각기술 들이 있으며, 이를 대체하는 신기술로 광촉매 반응을 이용함으로서 유기휘발물을 상온과 상압에서 광반응시켜 제거함으로서, 설치 및 조업비 측면에서 경제적인 이점이 있다.(중략)

  • PDF

Numerical Analysis of Turbulent Swirling Cold-Flow in a Cyclonic Coal Gasifier (선회분류층형 석탄가스화기내의 비반응 난류 선회유동장 해석)

  • 이진욱;나혜령;윤용승
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • Turbulent swirling cold-flow in a cyclonic gasifier has been analyzed by numerical analysis. Comparison of two dimensional and three dimensional analyses has shown that concept of equivalent slit is appropriate for the two dimensionalization of three dimensional phenomena. Flow characteristics have been scrutinized by varying swirl number which is a crucial parameter in determining the flow pattern of the cyclonic gasifier. Reactive flow field has been estimated by using theoretical swirl number and equivalent slit width for reactive flow. Results show that proper flow field for the reactive coal gasification can be formed by controlling the exit area and azimuthal location of coal burners.

  • PDF

Comparison of Solid Circulation Characteristics with Change of Lower Loop Seal Geometry in a Circulating Fluidized Bed (순환유동층에서 하부 루프실 형태 변화에 따른 고체순환 특성 비교)

  • Lee, Dong-Ho;Jo, Sung-Ho;Jin, Gyoung-Tae;Yi, Chang-Keun;Ryu, Ho-Jung;Park, Seung Bin
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.522-529
    • /
    • 2014
  • Circulating fluidized bed system consists of SEWGS reactor - lower loop seal - regeneration reactor - riser - cyclone - upper loop seal has been used for solid circulation between the SEWGS reactor and the regeneration reactor in a SEWGS system for pre-combustion $CO_2$ capture. A vertical type lower loop seal has been used in current system but this lower loop seal requires high gas flow rate through the lower loop seal for fluidization and smooth solid circulation, and consequently, causes slugging behavior sometimes. To overcome these disadvantages, inclined type lower loop seal was proposed by this study. Solid circulation characteristics with change of lower loop seal geometry were measured and compared in a bubbling - bubbling - riser type circulating fluidized bed using $CO_2$ absorbent (P-78) as bed material at ambient temperature and pressure. We could conclude that the inclined lower loop seal is better than the vertical type lower loop seal from the viewpoints of minimum flow rate requirement for stable solid circulation and solid height change during solid circulation.

유체의 유동조건하에서의 세포의 반응

  • Lee, Nam-U;Park, Jae-Seong
    • Journal of the KSME
    • /
    • v.51 no.10
    • /
    • pp.34-38
    • /
    • 2011
  • 이 글에서는 유체의 유동에 기인한 전단응력이 세포에 가해질 때 그 전단응력의 크기 및 세포의 종류에 따른 세포의 상태 변화를 관찰하는 연구 동향에 대하여 소개하고자 한다.

  • PDF

Analysis of CO2 Capture Efficiency in Relation to the Inlet Moisture Content of the Regenerator in the Continuous Process by using Sorbent Analysis (연속공정에서 고체흡수제의 입자분석을 통한 재생반응기 주입 수분량에 따른 CO2 회수효율 영향 분석)

  • Lee, Do-Young;Kim, Ki-Chan;Park, Young Cheol;Han, Moon-Hee;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.654-658
    • /
    • 2012
  • In this study, $CO_2$ capture efficiency in relation to the inlet moisture content of the regenerator was investigated using potassium-based sorbents in the continuous process composed of two bubbling fluidized-bed reactors, where solid outlet configuration in the regenerator was converted from underflow to overflow. XRD (X-ray Diffraction), SEM (Scanning Electron Microscope) and TGA were performed to find out the effect of water pre-treatment according to inlet moisture content in the regenerator. The $K_2CO_3{\cdot}1.5H_2O$ structure of solid sorbents has been increased as inlet moisture content of the regenerator increased. As a result, the $CO_2$ capture efficiency increased as the $K_2CO_3{\cdot}1.5H_2O$ structure of solid sorbents increased since the reactivity of the sorbents has been improved by that structure generated by the water pre-treatment. And $CO_2$ capture efficiency increased about 3~8% after sorbent outlet configuration of the regenerator was changed underflow to overflow.

The Effect of $H_2O/H_2S$ Concentration in the Coal Gas on the Desulfurization Performance of Zn-Based Sorbents in a Fluidized-Bed Reactor (석탄가스에 함유된 $H_2O/H_2S$ 농도가 유동층반응기에서 아연계 건식탈황제의 성능에 미치는 영향)

  • Park, Young-Cheol;Jo, ung-Ho;Jin, Gyoung-Tae;Lee, Seung-Yong;Yi, Chang-Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.871-872
    • /
    • 2009
  • 본 연구에서는 석탄가스에 함유된 $H_2O/H_2S$ 농도변화에 따른 세가지 종류의 아연계 탈황제의 반응성능을 회분식 유동층반응기에서 분석하였다. 가스화에서 생성되는 가스의 조성은 모사가스를 이용하여 입구의 $H_2O$$H_2S$ 농도를 변화시켜 실험을 수행하였다. $H_2O$의 농도는 5%부터 30%까지 $H_2S$의 농도는 0.5%에서 2%로 변화시켜 탈황성능을 분석하였다. 실험 결과 $H_2O$의 농도가 증가할수록 탈황성능이 감소하였다. 입구의 $H_2S$ 농도가 증가할수록 탈황반응기 후단의 $H_2S$ 농도 역시 증가하였으나, 탈황성능은 최저 99.5%로 건식탈황제를 이용하여 99% 이상의 $H_2S$ 제거 성능을 보이는 것을 확인하였다.

  • PDF

The Treatment of Concentrated Organic Alcoholic Distillery Wastewater by the Fluidized-Bed Biofilm Reactor (생물막 유동층 반응기에 의한 주정공장의 고농도 유기성 폐수처리)

  • 김동석;장희재
    • KSBB Journal
    • /
    • v.6 no.4
    • /
    • pp.345-350
    • /
    • 1991
  • The purpose of this study is to investigate biomass characteristics and organic removal efficiency by changing superficial upflow velocity and organic loading rate in treating alcoholic distillery wastewater. Since the biomass concentration and the thickness of biofilm are very sensitive to superficial upflow velocity, a high concentration of biomass could be achieved by decreasing superficial upflow velocity that lowered the organic removal efficiency. Therefore, superficial upflow velocity should be controlled as to give optimum conditions and removal efficiency. Generally, activated sludge system shows 70% COD removal efficiency at$1.5kgCOD/m^3{\cdot}day$, but the fluidized-bed biofllm reactor shows 80% COD removal efficiency even at 6kgCOD/$m^2{\cdot}day$.

  • PDF