• Title/Summary/Keyword: 반음

Search Result 125, Processing Time 0.024 seconds

Effects of External $Ca^{2+}$ ana the Inhibition of Na-pump on the Vanadate-induced Contraction in the Isolated Human and Rat Uterine Smooth Muscle (사람 및 흰쥐의 자궁근에서 Vanadate에 의한 수축에 미치는 외부 Calcium 및 Na-pump억제의 영향)

  • Jung, Jin-Sub;Han, Bok-Ki;Woo, Jae-Suk;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.18 no.2
    • /
    • pp.125-137
    • /
    • 1984
  • The effects of external $Ca^{2+}$ ana the inhibition of Na-pump on vanadate-induced contraction in isolated human and rat uterine smooth muscle were studied and the following results were observed. 1) Vanadate induced contraction in rat uterine muscle and showed maximal contraction at concentration of $5{\times}10^{-4}$M, and the contractile response to vanadate was more sensitive in human than rat uterine muscle. 2) Vanadate-induced contraction was not completely inhibited by $Ca^{2+}$ removal from PSS and the response to $Ca^{2+}$ removal was more sensitive in human than rat uterine muscle. 3) Vanadate-induced contraction decreased with increasing concentration of verapamil, but even in the presence of $3{\times}10^{-5}M$ verapamil which inhibited 100 K-induced contraction completely. about 40% of maximal contraction remained, and its amplitude was similar to that of contraction in $Ca^{2+}$-free solution. 4) Vanadate-induced contraction was increased by the inhibition of Na-pump and this increase also could be observed in the presence of $3{\times}10^{-5}M$ verapamil. 5) After pretreatment with $Ca^{2+}$-free PSS containing ouabain Vanadate-induced contraction was not increased, but the contractile response of these tissues to the addition of external $Ca^{2+}$ was remarkably increased in the presence of vanadate. 6) $3{\times}10^{-5}$M verapamil inhibited vanadate-induced $Ca^{45}$ influx completely, but after pretreatment with ouabain vanadate could induce remarkable $Ca^{45}$ influx even in the presence of verapmil. 7) With increasing the time of pretreatment with ouabain or $K^+$-free solution, the degree of increase in contraction by vanadate was more remarkable. 8) $10^{-4}M$ papaverine stowed a considerable inhibition of the increase in the vanadate-induced contraction by pretreatment with ouabain. 9) Acetylcholine-induced contraction increased with lengthening the duration of Na-pump inhibition even in the presence of verapamil. Considering above results it seems that the uterine muscle of human is more sensitive to vanadate than that of rat, and both internal and external $Ca^{2+}$ is utilized in vanadate·induced contraction. In the case of Na-pump inhibition several smooth muscle contracting agents seems to induce $Ca^{2+}$ influx which is not inhibited by verapamil. This $Ca^{2+}$ influx seems to be inhibited by papaverine and to be associated with membrane potential, although its precise characteristics is not certain.

  • PDF

Introduction and feasibility study of the HD-270 MLC (HD-270 MLC의 소개 및 유용성평가)

  • Kim Dae Young;Kim Won Taek;Lee Hwa Jung;Lee Kang Hyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • I. Purpose The multileaf collimator(MLC) has many advantages, but use of the MLC increased effective penumbra and isodose undulation in dose distribution compared with that of an alloy block. In this work, we introduced the HD-270 MLC, which can improve the above disadvantages of MLC, and reported its feasibility study. II. Method and Materials The HD-270 MLC is a technique which combines the use of the existing Siemens multileaf collimator(3D MLC) with patient translation perpendicular to the leaf plane. The technique produces a smoothed isodose distribution with the reduced isodose undulation and effective penumbra. To assess the efficacy of the HD-270 technique and determine the appropriate resolution, a polygonal shaped MLC field was made to produce field edge angles from 0 degree to 75 degree with a step of 15 degree. Each HD-270 group was generated according to the allowed resolution, i. e., 5, 3, and 2mm. The experiment was carried out on Primus, a Siemens linear accelerator configured with HD-270 MLC. The total 60 MU of 6 MV photon beam was delivered to X-Omat film(Kodak, USA) at a SAD of 100 cm and 1.5 cm depth in solid water phantom. Exposed films were scanned by Lumiscan75(LUMISYS) and analyzed using RIT113 software(Radiological Imaging Technology Inc., USA). To test the mechanical accuracy of table movement, the transverse, longitudinal, and vertical positions were controlled by a consol with ${\pm}5\;mm,\;{\pm}4\;mm,\;{\pm}3\;mm,\;and\;{\pm}2\;mm$ steps, and then measured using a dial gauge with an accuracy of 0.001 inch. During the experiments, the table loaded with about 50Kg human phantom to simulate the real treatment situation. III. Results The effective penumbra and isodose undulation became larger with increase the resolution and field edge angle. The accuracy of the table movement on each direction is good within the ${\pm}1\;mm$. IV. Conclusion Clinical use of the MLC can be increased by using of the HD-270 MLC which complements to the disadvantages of the MLC.

  • PDF

Feasibility Study of the microDiamond Detector for Measurement of Small Field Photon Beam (광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Ji, Young Hoon;Kim, Kum Bae;Lee, Sang Hoon;Min, Chul Kee;Jo, Gwang Hwan;Shin, Dong Oh;Kim, Seong Hoon;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.255-263
    • /
    • 2014
  • The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

A Study on the Planting and Cultivate of Hong Man-Seon(1643~1715)'s 'Salimkyungjae (山林經濟, The Economy of Forest)' (홍만선의 '산림경제(山林經濟)'에서 본 조경식물 재배(종수법(種樹法))와 가꾸기(양화법(養花法)))

  • Shin, Sang Sup
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.18-43
    • /
    • 2011
  • The results of study on planting and cultivate of Hong Man-Seon(1643~1715)'s 'Salimkyungjae(The Economy of Forest)' the first summative textbook of agricultural skill of South Korea, are as follows. First, 'Salimkyungjae' suggests that one can enrich oneself, eat fruits in fall, enjoy the shade of trees in summer, and enjoy flowers in spring if one plants tree with 10 year plan with knowledge of ecology. Second, the number of plants had increased continuously from the early Chosun Dynasty to the mid Chosun Dynasty. The 52 plants in the book are classified into 31 trees, 8 shrubs, 3 others, and 10 herbs, and 28 of them are fruit trees. Hence, we can see that the book is for the promotion of welfare. Third, planting(transplantation) is the best on January of the lunar calendar, and the second on February, and fertile soil should be added much. Trees must be planted as deep as once it was planted, and buttressed. It will sprout well if it is planted at the depth of one inch, and planting a cutting should be carried out at the early March with 5 inch and finger-thick branches. Grafting is the best when it begins to sprout. Fruit trees will bear many fruits if they are grafted at the direction of South, and fruits will be greater if the trees' branches are cutting off on January. Especially, January was selected for the best season of planting traditionally. Fourth, flower trees are planted or sowed with manure around January and February of the lunar calendar, and it is recommended to replant them into flowerpots with manure when having flower buds around March and April of the lunar calendar. It would bloom earlier when using water mixed with stable manure, and sulfur smoke can be used in order to change the flower color from red to white. Flowerpots would be placed at half shaded lot with being supported by bricks. Pomegranate, gardenia, camellia and four-season flower should be planted after flowers fallen. When flower trees are beside walls, they need to be rotated frequently since their branches all point toward house. Seeds need to be preserved in a sunny hut, where its entrance and ventilating openings would be at south because it is convenient to manage pots. Fifth, insects hidden at fruit trees would be destroyed by torch smoke when roosters cry on New year's day of the lunar calendar. Insects would be decoyed into straw hanged at dawn of Cheongmyeongday(淸明日). Insects on fruit trees would be controlled using sulfur powder to close up holes or sulfur smoke to fumigate. Particularly, it suggests that utilization of fertile soil would be the best solution for growing health plants and preventing pest.