• Title/Summary/Keyword: 반음

Search Result 125, Processing Time 0.025 seconds

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

The Ambiguous Characteristics of Classical Music in Films - Focused on The First Movement of Brahms' Symphony No.1 - (영화에 나타나는 클래식음악의 중의(重義)적 특성 - 브람스의 교향곡 제1번 제1악장을 중심으로 -)

  • Lee, Sang-Yoon
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.319-331
    • /
    • 2020
  • This study investigated the meaning of absolute music of the first movement of Brahms' symphony No. 1, which was used as film music in the films "Tetro" and "Savages" and interpreted the meaning of this music used in these two films. Therefore, the purpose of this study is to explore the characteristics that classical music can be interpreted ambiguously in films. In particular, it was examined whether film music could be interpreted in a new meaning rather than a program music. The first movement of Brahms' symphony No. 1 is in a sonata form and has the characteristics of a chromatic grammar of the romanticism. In "Tetro", the irony about the value connection between this music and the characters of the film, the composition process of this music and the historicity that appeared in the character story of the film presented important. On the other hand, in "Savages", the chromatic grammar of this music expresses the emotional meaning of the characters in the film and the atmosphere of the event. This can be said to be the role of program music. In particular, the scene in which this music is used at the end of "Tetro" shows an ambiguous characteristic that can interpret a piece of music in different meanings depending on which of the two characters appearing in the film interprets the music from the perspective of the character. And the fact that Brahms spent 21 years to complete this music and that Tetro, the main character of the film, spent about 10 years before going through theatrical scenario and submitting it to the festival in the film, coincide with each other in terms of historicality. This gives the meaning of understanding film music from a new point of view, not from the point of view of absolute music or program music. In addition, this musical setting made the music recognized as an essential element of the film and as an irreplaceable auditory theme. When classical music meets other art such as film, this ambiguity Characteristics of music will have a great influence on the new perception of classical music.

Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator (선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석)

  • Koo, Ki-Lae;Yang, Oh-Nam;Lim, Cheong-Hwan;Choi, Won-Sik;Shin, Seong-Soo;Ahn, Woo-Sang
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Aquisition of accurate beam data is very important to calculate a reliable dose distribution of the treatment planning system for small radiation fields in intensity-modulated radiation therapy(IMRT) and stereotactic radiosurgery(SRS). For the measurement of small fields, the choice of a suitable detector is important due to the shape gradient in profile penumbra, the lack of lateral electronic equilibrium, and the effect of effective detector volume. Therefore, this study was to analyze the dosimetric characteristics of various detectors in measurement of beam data for small fields of linear accelerator. 0.01cc and 0.13cc ion chambers (CC01 and CC13) and a stereotactic diode detector(SFD) were used for measurement of small fields. The beam data, including the percent depth dose, output factor, and beam profile were acquired under 6 MV and 15 MV photon beams. Measurements were performed with the field size ranging from $2{\times}2cm^2$ to $5{\times}5cm^2$. For $2{\times}2cm^2$ field size, the differences of the ratios of $PDD_{20}$ and $PDD_{10}$ measured by CC01 and SFD detectors were 1.02% and 0.12% for 6 MV and 15 MV photon beams, respectively. For field sizes larger than $3{\times}3cm^2$, the differences of values of $PDD_{20}/PDD_{10}$ obtained from each detector were 1.15% and 0.71% for 6 MV and 15 MV photon beams, respectively. The output factors obtained from CC01 and SFD for $2{\times}2cm^2$ field size were within 0.5% and 1.5% for 6 MV and 15 MV, respectively. The differences in output factor of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes were within 0.5%. Profile penumbras measured by the SFD, CC01, and CC13 detectors at three depths were average 2.7 mm and 3.5 mm, 3.4 mm and 4.3 mm, and 5.2 mm and 6.1 mm for 6 MV and 15 MV photon beams, respectively. In conclusion, it could be possible to use of the CC01 and SFD detectors for the measurement of percent depth dose and output factor for $2{\times}2cm^2$ field size, and to use of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes. CC01 and SFD detectors, consider ably smaller than the radiation field, should be used in order to accurately measure the profile penumbra for small field sizes.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

The Vegetation Structure and Management Solution of the Natural Monument (No.374) Pyeongdae-ri Torreya nucifera forest of Jeju (천연기념물 제374호 제주 평대리 비자나무 숲의 식생구조 및 관리방안)

  • Lee, Won-Ho;Oh, Hae-Sung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.3
    • /
    • pp.54-60
    • /
    • 2013
  • This study carried out a phytosociological research by Z.-M. school's method describing vegetation structure and management solution about nutmeg tree's(Torreya nucifera ) forests. The nutmeg tree's forests have developed intervale and hills in warm-temperate evergreen broad-leaved forests zone. The nutmeg tree's forests composed 50 familly, 80 genus, 88 species divided two syntaxa(typical sub-community, Arachniodes aristata sub-community) by species composition and correspond to habitat condition. The nutmeg tree's forests show a uniform forest's structure which composed 3~4 layer of sub-tree and shrub. And it was worthy of special mention which characterized diagnostic species of Camellietea japonicae in the warm-temperate evergreen broad-leaved forests. In case of forests floor, were a high rate in order of Ophiopogon japonicus, Polystichum tripteron, Arisaema ringens. And Oplismenus undulatifolius which represent mantle communities as well. This indicates that the nutmeg tree's forests are exposed by humman effects sustainedly. The nutmeg tree's young trees appeared a high rate at half shade and shade. The vigorous tree species have to spacing cutting instead of the heavy thinning that consist in with a shout of declining astructur and function of the forest ecosystem for maintaining a nutmeg tree's forests. And we suggest for the density regulation of the sub-tree and shrub. In conclusion, need to the continuous monitoring about the vegetation structure and management solution for the sustainable nutmeg tree's forests.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Prolyl Endopeptidase-inhibiting Isoflavonoids from Puerariae Flos and Some Revision of their $^{13}C-NMR$ Assignment (갈화의 Prolyl Endopeptidase 저해 활성 Isoflavonoid 및 이들의 $^{13}C-NMR$ Assignment)

  • Kim, Kyung-Bum;Kim, Sang-In;Kim, Jong-Sik;Song, Kyung-Sik
    • Applied Biological Chemistry
    • /
    • v.42 no.4
    • /
    • pp.351-355
    • /
    • 1999
  • In order to find anti-dementia drugs from natural products, prolyl endopeptidase inhibitors were purified from Puerariae Flos by consecutive solvent partition, followed by silica gel, Sephadex LH-20, and HPLC. Four isoflavonoid inhibitors were isolated and identified as tectorigenin, genistein, 5,7-dihydroxy-4',6-dimethoxyisoflavone, and 5-hydroxy-6,7,4'-trimethoxyisoflavone by means of instrumental analyses including $^{1}H-$, $^{13}C-$, $^{2}D-NMR$ and MS and $IC_{50}$ values against PEP were 5.30 ppm$(17.7\;{\mu}M)$, 10.39 ppm$(38.5\;{\mu}M)$, 13.92 ppm$(44.3\;{\mu}M)$, and 20.61 ppm$(62.8\;{\mu}M)$, respectively. Some previous mistakes in $^{13}C-NMR$ assignment were revised by careful investigation of HMBC and HMQC data.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Habitat Environment of Epimedium koreanum Nakai (삼지구엽초(三枝九葉草) 자생지(生地生) 환경(環境) 특성(特性))

  • Park, Kyeong-Yeol;Choi, Byoung-Ryourl;Yi, Eun-Sub;Kim, Sun-Jae;Park, Cheol-Ho
    • Korean Journal of Medicinal Crop Science
    • /
    • v.6 no.1
    • /
    • pp.51-56
    • /
    • 1998
  • This study was carried out to evaluate environmental and ecological characteristics of natural habitat for cultivation of Epimedium koreanum. Habitat of E. koreanum was the slope foot of mountain descending gradually toward mostly northwest from top of mountain with slope of $2{\sim}20%$ and the altitude ranged from 60 to 400m above the sea level. Some physiochemical characteristics of habitat soil were as follows: pH, $4.1{\sim}5.8$, organic matters content, $4.9{\sim}6.6%$ and cation exchange capacity, $14.8{\sim}34.3\;me/100g$ soil, respectively. Habitats were shaded by deciduous broad-leaved tree mainly, and compared with those of naked area, relative photon flux density was $3.5{\sim}13.1%$ and relative luminance was $3.3{\sim}11.9%$ due to shading. Air temperature of habitat under shade was $4.3{\sim}6.5^{\circ}C$ lower than that of naked area. Habitat soil temperature was lower than that of naked area but temperature range was smaller than that of naked area. E. koreanum plants were growing with semishading plants under shade of tree leaf. From investigation of natural characteristics of habitat, it was concluded that E. koreanum plant would grow at place with a little change in temperature and moisture of soil which was caused by shading and mulching with litterfall of broad-leaved tree.

  • PDF

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF