반송동력과 건물층고 저감형 공조시스템 개발 (Development of HVAC System to Lower the Conveyance Energy and Building Height)

  • 김정엽;신현준
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

에너지 절약적 공조시스템 선정을 위한 기초적 연구 (A Study on the Energy Conservational HVAC System Design Strategies)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.58-63
    • /
    • 2007
  • Lots of needs are being paid for how to design HVAC system in large-scale buildings. Increasing awareness of energy use is main point of this research. HVAC systems' energy characteristics are not clearly identified and understood, so the optimal design of HVAC system is very important. The energy parameters of HVAC design that are system input energy, water/air moving equipments (pumps/fans) energy and outdoor air conditioning energy for IAQ are important. The purpose of this study is to provide the basic data for energy conservational HVAC design strategies.

  • PDF

EMMC공정을 이용한 수산물 가공공장 폐수처리에서 동력학적 인자 평가와 유출수반송의 영향 (Evaluation of Kinetic Constant and Effect of Effluent Recycling in Wastewater Treatment from Fisheries Processing Plant using EMMC Process)

  • 정병곤
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2009
  • 수산물 가공공장 폐수의 생물학적 처리를 위하여 미생물 능동포획방식의 일종인 EMMC(Entrapped Mixed Microbial Cell)공정을 적용하여 유기물 및 질소제거에 대한 동력학적 인자를 산출하였으며 전체 시스템 운전효율에 유출수 재순환이 미치는 영향을 평가하였다. 동력학적 인자 중 유기물의 세포 전환계수 Y의 경우 일반적인 활성슬러지 공정에서 보고된 Y값에 비하여 상당히 낮은 값을 나타내어 활성 슬러지 공정에 비해 슬러지 생성량을 상당히 줄일 수 있음을 확인할 수 있었다. 내생호흡 계수 $k_e$값 역시 일반적인 활성슬러지법에 있어서의 값과 비교할 때 상당히 낮은 값을 나타내었다. 질산화 미생물의 미생물 전환계수 Y 및 내생호흡계수 $k_e$, 반포화상수 $k_s$ 값을 일반적인 부유성장형 질산화 반응조에서 구한 값들과 비교하였다. Y값은 본 연구에서 구한 값과 유사하였으며 내생호흡 계수는 낮았으며 반포화 상수의 경우는 본 연구에서의 값이 훨씬 높은 값을 나타내었다. 이를 통하여 질산화 박테리아에 있어서도 포괄 고정화 공법이 일반적인 부유성장 반응조에 비하여 기질 친화도가 높은 것을 알 수 있었다. 내부 재순환이 전체 반응조 운전효율에 미치는 영향을 평가하기 위하여 내부 순환율을 1.5Q, 2.0Q, 2.5Q, 3.0Q로 변화시켜가며 운전한 결과 내부 순환을 증가는 질산화보다는 탈질화 효율의 증가에 더 큰 영향을 미치며 내부 순환율의 최적화는 anoxic조의 운전효율 증대에 초점을 맞추어야 하는 것으로 나타났다.

  • PDF

Chilled Beam 공조시스템의 유인성능 해석 (Study on Induction Capability of Chilled Beam HVAC System)

  • 김정엽;신현준;김지석;주상현
    • 설비공학논문집
    • /
    • 제25권5호
    • /
    • pp.255-260
    • /
    • 2013
  • Since a chilled beam system can reduce the conveyance energy for air conditioning and has many advantages in terms of constructability and indoor environment, its supply has been rapidly expanding mainly in Europe. For this chilled beam system to be effectively available in Korea, a product suitable for the domestic climatic environment and HVAC system operating conditions needs to be developed. Also, domestic products need to have an edge in cost competitiveness compared to overseas products. In this study, the induction structure of a chilled beam is deduced and an analysis on the induction performance is carried out while the chilled beam system that meets domestic situations is in the process of development.

초고층 건물의 층고저감을 위한 공조시스템

  • 신현준;김보철
    • 대한설비공학회지:설비저널
    • /
    • 제31권1호
    • /
    • pp.9-14
    • /
    • 2002
  • 산업의 발전에 따른 도시화의 영향으로 대도시에서는 가용공간을 확보하기 위하여 건물의 고층화와 지하공간의 개발이 활발하게 이루어지고 있다. 최근 증가추세에 있는 초고층주상복합건물, 초고층아파트는 건물의 높이가 증가함으로 인하여 건축공사비의 증가는 물론 설비적인 측면에서는 저층부의 수압이 상승 하여 높은 수압과 수격작용(water hammer)에 대한 배관 및 기기의 내압강도와 안전대책이 요구된다. 또한 건물의 초고층화로 인하여 열원에서 공조기까지, 공조기에서 실내기기까지의 수직거리 (vertical distance)가 길어지게 되어 연장된 공조덕트 및 배관 의 길이로 인해 반송동력비의 상승에도 큰 영향을 미치게된다. 이러한 문제점을 해결하기 위하여 기기 및 재료의 선정시 내압을 고려하거나 기기의 적정배치와 조닝(zoning)을 통해 상기의 문제점을 해결하는 방법을 적극 채용하고 있다. 하지만 보다 근본적인 문제해결 방법으로 건물의 층고저감에 의한 건축공사비 및 연 간운전비의 절감을 통한 건물에서의 소비에너지량 감소로 부존자원이 부족한 우리나라의 에너지수급정책에 기여하여야 할 것이다. 본 고에서는 건축물의 층고저감 효과를 얻을 수 있는 공조시스템에 대해 전반적으로 기술하고자 한다.

  • PDF

횡자속 선형전동기를 이용한 스토커 주행축 적용에 관한 연구 (A Study on Travel Axis of Stocker Using TFLM)

  • 전진용;문인호;김규식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.104-106
    • /
    • 2006
  • LCD 원판이 세대별로 대형, 중량화됨에 따라 제조 공정라인의 자동 반송장비도 대형화 되어 가고 있는 추세다. 기존 스토커는 주행축에 회전형 모터와 기계적 동력변환 장치를 사용하고 있어, 복잡한 구조와 기계적 마찰에 의한 잦은 유지, 보수가 필요하게 되고 파티클 발생을 최소화 시켜야 하는 문제점을 안고 있다. 따라서 이런 문제점들을 해결하기 위해, 본 논문에서는 횡자속 선형전동기를 적용하고 제안된 제어 알고리즘 및 제어기, 전력변환장치를 제작해서 대형, 고출력, 장거리화 되고 있는 스토커의 주행축에 실험, 검증하였다.

  • PDF

장거리 이송용 고출력 영구자석 여자 횡자속 선형전동기 제어에 관한 연구 (A Study on Control of High Power PM Excited TFLM for Long Distance)

  • 전진용;황계호;김지원;김규식
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.471-479
    • /
    • 2006
  • LCD 원판이 세대별로 대형, 중량화됨에 따라 제조, 공정라인의 자동 반송장비도 대형화 되어 가고 있는 추세다. 기존 스토커는 크레인의 주행축에 회전형 전동기와 기계적 동력변환 장치를 사용하고 있어, 복잡한 구조와 기계적 마찰에 의한 잦은 유지, 보수가 필요하게 되고 파티클 발생을 최소화 시켜야 하는 문제점을 안고 있다. 이런 문제점들을 해결하기 위해, 본 논문에서는 단위면적당 추력이 큰 영구자석 여자 횡자속 선형전동기를 적용하고 제안된 제어 알고리즘 및 제어기, 전력변환장치를 제작해서 대형, 고출력, 장거리화 되고 있는 7세대 스토커의 주행축에 실험, 검증하였다.

시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어 (Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process)

  • 이승철;김수창;노광철;박명호
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.463-469
    • /
    • 2009
  • 시멘트 포장공정에서 발생하는 비산분진을 효율적으로 제거하기 위해 3가지 환기방식(국소배기시스템, 정전식스크러버시스템, 국소급기시스템)을 도입하고 풍량을 변화시키며 총 9가지의 조건에서 실험을 수행하였다. 분진의 농도는 시멘트분진 입자분포 특성을 고려하여 PM2.5, PM10, TSP로 구분하여 측정하였다. 3가지 환기방식에 대한 집진효율을 분석한 결과, 기존의 국소배기시스템과 정전식스크러버시스템이 같이 사용되는 경우 가장 효율적인 것으로 나타났다. 또한 정정식스크러버시스템의 풍량 증가에 따른 입자의 질량농도감소율이 큰 차이가 없는 것을 확인할 수 있었고 이로부터 정정식스크러버시스템을 $2,700m^3/h$ 풍량으로 운전하는 것이 에너지절약 관점에서 효율적인 것이라고 판단되었다. 각 환기방식별 환기성능을 국소배기시스템의 풍량으로 환산한 결과, 대체시스템(정전식스크러버시스템, 국소급기시스템)분진제거성능이 우수한 젓으로 나타났고 정전식스크러버시스템이 국소급기시스템보다 상당히 효율적인 것으로 나타났다. 따라서 기존의 국소배기시스템파 정전식스크러버시스템을 동시에 가동한다면 국소배기시스템의 풍량만을 증가시키는 경우에 비해 반송동력을 줄일 수 있어 분진제거와 에너지절감측면에서 훨씬 효율적이라는 것을 알 수 있었다.