• Title/Summary/Keyword: 반사-투과형

Search Result 125, Processing Time 0.027 seconds

An Experimental Study for the Relationship of Photon Flux Path ann Layered Properties of Biological Tissue with S- D Separation (S-D간격 변화에 따른 광양자의 경로와 생체조직의 계층성에 대한 실험적 연구)

  • 고한우
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 1994
  • A probe was designed to study the relationship of photon flux path and layered properties of bilogical tissue. The result shows that different wavelengths have different flux path and maximum reflectance position with separation. The source-detector separations on maximum reflectance of IR and GR were 7.5 mm and 2.5 mmm each other and layered properties of tissue can be discriminated bye the change of S-D separation using designed probe.

  • PDF

열처리 온도에 따른 자외선 발광다이오드용 산화물/금속/산화물 투명전극의 전기적/광학적 특성

  • Lee, Jae-Hun;Kim, Gyeong-Heon;An, Ho-Myeong;Kim, Tae-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.418-419
    • /
    • 2013
  • 현재, 인듐 주석 산화물(indium tin oxide, ITO) 박막은 가시영역에서 전기적 특성 및 광학적 특성이 우수하기 때문에 평면 디스플레이(flat displays), 박막 트랜지스터(thin film transistors), 태양전지(solar cells) 등을 포함한 광소자에 투명전도성산화물(transparent conducting oxide, TCO) 전극으로 가장 일반적으로 사용되고 있다. 하지만, 이 물질은 밴드갭이 3.4 eV로 다소 작아 다양한 분야의 의료기기, 환경 보호에 응용 가능한 자외선 영역에서 상당히 많은 양의 광흡수가 발생하는 치명적인 문제점을 가지고 있다. 또한, 인듐(Indium)의 급속한 소비는 인듐의 매장량의 한계로 인해 가격을 상승시키는 주요한 원인으로 작용하고 있다. 한편, InGaN 기반의 자외선 발광다이오드 분야에서는 팔라듐(Pd) 기반의 반투명 전극과 은(Ag) 기반의 반사전극을 주로 사용하고 있지만, 낮은 투과도와 낮은 굴절률을 때문에 여전히 자외선 발광다이오드의 광추출 효율(extraction efficiency)에 문제점을 가지고 있다. 따라서 자외선 발광다이오드의 외부양자 효율(external quantum efficiency, EQE)을 높이기 위해 높은 투과도와 GaN와 유사한 굴절률을 가지는 p-형 오믹 전극을 개발해야 한다. 본 연구에서는 초박막의 ITO (16 nm)/Ag (7 nm)/ITO (16 nm) 다층 구조를 갖는 투명전도성 전극을 제작한 후, 열처리 온도에 따른 전기, 광학적 특성에 향상에 대해서 조사하였다. 사용된 산화물/금속/산화물 전극의 구조는 유기발광 다이오드(organic light emitting diode, OLED), 태양전지 등에 많이 사용되는 안정적인 투명 전극을 자외선 LED 소자에 처음 적용하여, ITO의 전체 사용량은 줄이고, ITO 사이에 금속을 삽임함으로써 금속에 의한 전기적 특성 향상과 플라즈몬 효과에 의한 투과도를 높일 수 있는 장점을 가지고 있다. 실험 결과로는, $400^{\circ}C$에서 열처리한 ITO/Ag/ITO 다층 구조는 365 nm에서 84%의 광학적 특성과 9.644 omh/sq의 전기적 특성을 확인하였다. 실험 결과로부터 좀 더 최적화를 수행하면, ITO/Ag/ITO 다층 구조는 자외선 발광다이오드의 투명전도성 전극으로 사용될 수 있을 것이라 기대된다.

  • PDF

The Wireless Controller using PCB mounted PIC MICOM Control Method for Tactical Training (PIC MICOM 전술훈련용 무선 센서 컨트롤러)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.51-56
    • /
    • 2012
  • Nowadays, For that reason, the tactical training system that were applied to recruit training center and police training, a real-life survivor game place is a drill using conventional training methods that there is no special training system at open terrain and field, there is no training accomplishment in conformity with battlefield situation portrayal. Therefore, this paper developed the tactical training evaluation system and real-time monitoring system that is compensated the defect and controlled sensing, interlock with PC as wireless a way of GUI using PCB mounted MICOM. This system evaluate drill that regulate sensor control module, tactical training system remotely according to what they should do, is installed to fit the occasion as to be reflected or transmission choosingly and is a 24V H/W drive module.

Fabrication and Design of Multi-Layered Radar Absorbing Structures of MWNT-Filled Glass/Epoxy Plain-Weave Composites (MWNT가 첨가된 유리/에폭시 평직 복합재료로 이루어진 다층형 전자파 흡수 구조체의 제작 및 설계)

  • Lee, Sang-Eui;Kang, Ji-Ho;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.11
    • /
    • pp.24-32
    • /
    • 2005
  • The object of this study is to design radar absorbing structures(RAS) with load-bearing ability in X-band. Glass/Epoxy plain-weave composites of excellent specific stiffness and strength, containing multi-walled carbon nanotubes(MWNT) added to induce dielectric loss were fabricated. The observation of microstructure and the permittivity of the composites confirmed that the materials are suitable to be used for radar absorbing material. Genetic algorithm and theory for reflection/transmission of electromagnetic waves in a multi-layered RAS were applied to conduct an optimal design of a RAS composed of the developed composites. We observed that the thickness per ply changes with the number of ply and MWNT contents. The fabrication process was proposed considering the problem and applied to fabricate a designed RAS and the theoretical and measured reflection loss of the RAS were also found in good agreement.

Single Source Chemical Vapor Deposition of Epitaxial Cubic SiC Films on Si (입방형 탄화규소 박막의 적층 성장)

  • 이경원;유규상;구수진;김창균;고원용;조용국;김윤수
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.2
    • /
    • pp.133-138
    • /
    • 1996
  • Epitaxial cubic silicon carbide films have been deposited on carbonized Si(001) substrates using the single precursor 1, 3-disilabutane in the temperature range 900-$1000^{\circ}C$ under high vacuum conditions. The films grown were characterized by in situ RHEED, XPS, XRD, x-ray pole figure, SEM, and TEM. The results show that epitaxial cubic SiC films with smooth morphology and good crystallinity were formed in this temperature range. The single precursor 1, 3-disilabutane has been found suitable for the epitaxial growth of cubic SiC on Si(001) substrates.

  • PDF

Evaluation Study of Performance for Solar Energy Blocking of Smart Windows based on Phase Retardation Film (Phase Retardation 필름 기반 스마트윈도우의 태양열차단 성능 평가 시험 연구)

  • Il-Gu Kim;Ho-Chang Yang;Young-Min Park;Yo-Han Suh;Seung Hyun Lee;Young Kyu Hong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.3
    • /
    • pp.67-71
    • /
    • 2024
  • A smart window based on a retarder can transmit or block polarized lights by overlapping two smart windows. In the study, tests were conducted to evaluate the performance of blocking solar heat using smart windows with a size of 300×300 mm2. Solar heat gain coefficient (SHGC) values were derived through simulation using transmission and reflectance data of the smart windows. As a result of the simulation, it showed that SGHC is effective in blocking solar heat by obtaining values of 0.722 and 0.615 in transmission and blocking mode of smart windows, respectively. The test boxes were fabricated in order to verify the effect of suppressing temperature rise when applying smart windows, the inside temperature in test boxes, which are installed bare glass (reference) and two smart windows with transmission and blocking mode, were measured at 10 minutes-interval for 7 days. As of 1 p.m., the inside temperature of the test boxes with the smart windows applied showed lower temperature compared to the reference. In particular, on the day when the temperature of reference box was the highest at 66.1℃, the temperature of the test box with the smart window applied showed 61.0℃, which was lowered by 5.1℃.

A study on the application of dichroic mirror for the improvement of luminance and luminous efficacy in an AC Plasma Display Panel (AC-PDP의 휘도와 효율 향상을 위한 Dichroic Mirror의 응용에 관한 연구)

  • 송병무;김중균;황만수;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.98-103
    • /
    • 2001
  • A new application of dirchroic mirror for the improvement of luminance and luminous efficacy in an AC-Plasma Display Panel (PDP) is suggested. Only about half of the Vacuum Ultraviolet (VUV) generated in the reflective PDP cell is used for the excitation of the phosphor. We are suggesting an idea of adopting a dichroic mirror which can reflect the VUV toward the phosphor which otherwise is absorbed by the front panel. The optical constants of the thin films of dirhroic mirror were determined from the photometric measurements through an iteration process of matching calculated and measured values of the reflectance and transmittance in the VUV wavelength region. From these results, we could design such a filter whose high reflection zone is centered at 147nm by a computer simulation accurately. The 147nm VUV is radiated from Xenon 3Pl state which is dominantly used to activate the phosphor in the PDP cell. The dichroic mirror was made with an electronbeam evaporator and its reflectance was measured by a reflectometer. We confirmed the usefulness of the dichroic mirror for the improvement of efficiency with experiments done by test panels. The panel with mirror shows improved luminance and luminous efficacy by 20∼30%.

  • PDF

An analysis of acoustic pressure in the center of double pipe inside of a cylindrical vibrator (원통형 진동자 내부의 이중관 중심에서의 음압해석)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.165-171
    • /
    • 2017
  • The effect of the concentric solid tube inserted inside the vibrator on the sound field distribution was analyzed for the sound waves focused on the center axis in the fluid - filled cylindrical piezoelectric transducer. The sound waves radiated from the inside of the cylindrical piezoelectric vibrator are transmitted through the fluid medium and are reflected or transmitted on the wall surface of the solid tube, and are focused on the central axis. At this time, the sound field distribution centered on the acoustic tube varies depending on the acoustic impedance and the thickness of the solid tube. In order to theoretically analyze this, the transfer matrix for each medium is derived, and the sound pressure level at the center axis is theoretically analyzed. For the acrylic tube with various thicknesses, the changing trend in the sound pressure level measured on the central axis agrees well with the result of the theoretical analysis, and it confirmed that the sound pressure formed at the center changes very sensitively with the thickness of the solid tube.

Investigation of Ground Remote Sensing Technique Using CCD Camera (CCD 카메라를 이용한 지상원격탐사 기술 개발)

  • Kim, Eung Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.325-333
    • /
    • 2006
  • Recently, in the case of observing the global environment, satellite remote sensing technology has been important. It's because satellite remote sensing is valuable for assessing relatively large areas. But now, small scale remote sensing techniques are needed which can be applicable to the detail investigation of plant tree areas which afforest land after the large scale construction of roads, dams and airports. In this study, we tried to develop and propose a lower altitude sensing technique which can be used in ground remote sensing by using a CCD camera. As a result of this investigation the following can be concluded: We recognized the transference characteristics of filters which were used in comparative tests about the four ground remote sensing devices. We also found that the near-IR camera could be used for an imaging spectral radiometer in the extraction of the vegetation index. Furthermore, we found that the vegetation index has varied hour by hour during the day of the experiment. Finally, we brought about an increase phase of the NDVI in a forest fire, which caused considerable damage, by developing new ground remote sensing technology.

Implementation of the wearable PTT measurement system for health monitoring during daily life (일상생활 건강 모니터링을 위한 착용형 PTT 측정 시스템의 구현)

  • Ye, Soo-Young;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.220-226
    • /
    • 2011
  • Device of the ECG and pulse signal was made to measure PTT signal using non-invasive method and possible to wearable. PTT alterations were observed according to position change using implemented system.It was needed to ECG and pulse to detect the PTT, used the photoplethymorgraphy appeared to change the blood volume. And also wireless sensor node which was able to Zigbee compatibility was used to transfer the detected ECG and pulse signal to PC. Noise was removed from transit data and algorithm was applied to calculate the PTT. After the evaluation of both the conventional measuring systems and the proposed photoplethymography measuring system, a highly effective and efficient formation and distribution sequences were found within the proposed photoplethymography measuring system.