• Title/Summary/Keyword: 반복 재구성법

Search Result 49, Processing Time 0.023 seconds

Design of military supply chain network using MIP & Simulation model (혼합정수계획법과 시뮬레이션 기법을 이용한 군 공급사슬망 설계)

  • Lee, Byeong-Ho;Jeong, Dong-Hwa;Seo, Yoon-Ho
    • Journal of the military operations research society of Korea
    • /
    • v.34 no.3
    • /
    • pp.1-12
    • /
    • 2008
  • Design of supply chain network (SCN) is required to optimize every factor in SCN and to provide a long-term and strategic decision-making. A mathematical model can not reflect the real world because design of SCN contains variables and stochastic factors according to status of its system. This paper presents the designing methodology of military SCN using the mathematical model and the simulation model. It constructs SCN to minimize its total costs using the Mixed Integer Programming (MIP) model. And we solve problems of a vehicle assignment and routing through adaptation of experiment parameters repeatedly in the simulation model based on the results from the MIP model. We implement each model with CPLEX and AutoMod, and experiment to reconstruct SCN when the Logistic Support Unit is restricted to support military units. The results from these experiments show that the proposed method can be used for a design of military SCN.

Speaker-adaptive Word Recognition Using Mapped Membership Function (사상멤버쉽함수에 의한 화자적응 단어인식)

  • Lee, Ki-Yeong;Choi, Kap-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.40-52
    • /
    • 1992
  • In this paper, we propose the speaker adaptive word recognition method using a mapped membership function, in order to absorb a fluctuation owing to personal difference which is a problem of speaker independent speech recognition. In the training procedure of this method, the mapped membership function is made with the fuzzy theory introducded into a mapped codebook, between an unknown speaker's spectrum pattern and a standard speaker's one. In the recognition procedure, an input pattern of an unknown speaker is reconstructed to the pattern which is adapted to that of a standard speaker by the mapped membership function. To show the validity of this method, word recognition experiments are carried out using 28 DDD area names. The recognition rate of the conventional speaker-adaptive method using a mapped codebook by VQ is 64.9[%], and that made by a fuzzy VQ is 76.2[%]. Throughout the experiment using a mapped membership function, we can achieve 95.4[%] recognition rate. This shows that our proposed method is more excellent in recognition performance. Moreover, this method doesn't need an iterative training procedure to make the mapped membership function, and memory capacity and computation requirements for this method are reduced to 1/30 and 1/500 time of those for the conventional method using a mapped codebook, respectively.

  • PDF

Three Dimensional Shape Estimation by Shading Analysis of Endoscopic Image (음영분석에 의한 내시경 영상의 3차원 형체 추정에 관한 연구)

  • Lee, Tae-Su;Cha, Eun-Jong;Yun, Se-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.499-506
    • /
    • 1995
  • A new numerical method estimated three dimensional shape of the internal surface of the stomach by analyzing the shading data of endoscopic image. First analyzed was the inherent instrumentational characteristics of the endoscope system, followed by the analysis of the stomach surface properties, both of which affected the imaging properties. We employed these prior informations to implement the iterative algorithm of shading analysis based on Hom's variational approach. The present algorithm was validated by performing simulation on a $256{\times}320$ image data chosen from original $512{\times}512$ image of the stomach surface model. The best 3-dimensional estimation of the surface was achieved with the Lagrangian multiplier, of 0.3, when the algorithm best converged showing minimal estimation error.

  • PDF

A Study on the Purpose and Method of the Reading on the Reading Theory in the Cho-seon Dynasty (조선시대 독서론에서의 독서 목적과 방법에 관한 연구)

  • Byoungmoon So
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.57 no.2
    • /
    • pp.31-50
    • /
    • 2023
  • The aim of this study is to explore the purpose and method of reading by examining relevant research from various academic fields. According to the reading theory in the Cho-seon Dynasty, reading was classified as either a way of gaining fame, becoming a gentle man, or solving problems. However, this views have been largely replaced by the belief that reading serves two main purposes: self-discipline and practical usage in this study (Confucian perspectives have been excluded from this approach). The traditional reading method, known as sukookdok-jeongsa, influenced by Chu-tzu's reading, emphasized a fluent reading and a deep reading. A fluent reading (sukookdok) method involved a reading aloud, memorizing, and a repeated reading for the literal decoding. After decoding, a deep reading (jeongsa) involved a reading while taking notes, a reading with reference and a repeated reading for the optimal comprehension. A fluent reading in the traditional reading theory is succeeded by 'a reading for liberal arts' and a deep reading is succeeded by 'a reading for learning'. The sukookdok-jeongsa's various reading methods are useful enough to apply to reading education in the school library. But 'a reading for fun' did not appear in the traditional reading theory.

A Study of Experimental Image Direction for Short Animation Movies -focusing in short film and (단편애니메이션의 실험적 영상연출 연구 -<탱고>와 <페스트 필름>을 중심으로)

  • Choi, Don-Ill
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.375-391
    • /
    • 2014
  • Animation movie is a non-photorealistic animated art that consists of formative language forming a frame based on a story and cuts describing frames that form the cuts. Therefore, in expressing an image, artistic expression methods and devices for a formative space are should be provided in a frame while cuts have the images between frames faithfully. Short animation movie is produced by various image experiments with unique image expressions rather than narration for expressing subjective discourse of a writer. Therefore, image style that forms unique images and various image directions are important factors. This study compared the experimental image directions of and , both of which showed a production method of film manipulation. First, while uses pixilation that produces images obtained from live images through painting and many optical disclosure process on a cell mat, was made with diverse collage techniques such as tearing, cutting, pasting, and folding hundreds of scenes from action movies. Second, expresses non-causal relationship of characters by their repetitive behaviors and circulatory image structure through a fixed camera angle, resisting typical scene transition. On the other hand, has an advancing structure that progresses antagonistic relationship of characters through diverse camera angles and scene transition of unique images. Third, in terms of editing, uses a long-take short cut technique in which the whole image consists of one short cut, though it seems to be many scenes with the appearance of various characters. On the other hand, maximizes visual fun and commitment by image reconstruction with hundreds of various short cuts. That is, both works have common features of an experimental work that shows expansion of animated image expressions through film manipulation that is different form general animation productions. On top of that, delivers routine life of diverse human beings without clear narration through image of conceptualized spaces. expresses it in a new image space through image reconstruction with collage technique and speedy progress, setting a binary opposition structure.

Usability Evaluation of Applied Low-dose CT When Examining Urinary Calculus Using Computed Tomography (컴퓨터 단층촬영을 이용한 요로결석 검사에서 저선량 CT의 적용에 대한 유용성 평가)

  • Kim, Hyeon-Jin;Ji, Tae-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.6
    • /
    • pp.81-85
    • /
    • 2017
  • The aim of this study was to evaluate the usability of applied Low dose Computed Tomography(LDCT) protocol in examining urinary calculus using computed tomography. The subjects of this study were urological patients who visited a medical institution located in Busan from June to December 2016 and the protocol used in this study was Adaptive Statistical Iterative Reconstruction: low-dose CT with 50% Adaptive Statistical Iterative Reconstruction (ASIR). As results of quantitative analysis, the mean pixel value and standard deviation within kidney region of image(ROI)of the axial image were $26.21{\pm}7.08$ in abdomen CT pre scan and $20.03{\pm}8.16$ in low-dose CT. Also the mean pixel value and standard deviation within kidney ROI of the coronal image were $22.07{\pm}7.35$ in abdomen CT pre scan and $21.67{\pm}6.11$ in low dose CT. The results of qualitative analysis showed that four raters' mean values of observed kidney artifacts were $19.14{\pm}0.36$ when using abdomen CT protocol and $19.17{\pm}0.43$ in low-dose CT, and the mean value of resolution and contrast was $19.35{\pm}0.70$ when using abdomen CT protocol and $19.29{\pm}0.58$ in low-dose CT. Also the results of a exposure dose analysis showed that the mean values of CTDIvol and DLP in abdomen CT pre scan were 18.02 mGy and $887.51mGy{\cdot}cm$ respectively and the mean values of CTDIvol and DLP when using low-dose CT protocol were 7.412 mGy and $361.22mGy{\cdot}cm$ respectively. The resulting dose reduction rate was 58.82% and 59.29%, respectively.

Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D (PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가)

  • Park, Sun-Myung;Hong, Gun-Chul;Lee, Hyuk;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • Purpose: There has been recent interest in the radioactivity uptake and image acquisition of radioactivity concentration. The degree of uptake is strongly affected by many factors containing $^{18}F$-FDG injection volume, tumor size and the density of blood glucose. Therefore, we investigated how radioactivity uptake in target influences 2D or 3D image analysis and elucidate radioactivity concentration that mediate this effect. This study will show the relationship between the radioactivity uptake and 2D,3D image acquisition on radioactivity concentration. Materials and Methods: We got image with 2D and 3D using 1994 NEMA PET phantom and GE Discovery(GE, U.S.A) STe 16 PET/CT setting the ratio of background and hot sphere's radioactivity concentration as being a standard of 1:2, 1:4, 1:8, 1:10, 1:20, and 1:30 respectively. And we set 10 minutes for CT attenuation correction and acquisition time. For the reconstruction method, we applied iteration method with twice of the iterative and twenty times subset to both 2D and 3D respectively. For analyzing the images, We set the same ROI at the center of hot sphere and the background radioactivity. We measured the radioactivity count of each part of hot sphere and background, and it was comparative analyzed. Results: The ratio of hot sphere's radioactivity density and the background radioactivity with setting ROI was 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, and 1:26.90 in 2D, and 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, and 1:23.24 in 3D. The differences of percentage were 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, and 11.06% in 2D, the minimum differentiation was 3.47%, and the maximum one was 11.06%. In 3D, the difference of percentage was 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, and 22.69%. Conclusion: The difference of accumulated concentrations is significantly increased following enhancement of radioactivity concentration. The change of radioactivity density in 2D image is affected by less than 3D. For those reasons, when patient is examined as follow up scan with changing the acquisition mode, scan should be conducted considering those things may affect to the quantitative analysis result and take into account these differences at reading.

  • PDF

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

Changes of Sputum Matrix Metalloproteinases and Tissue Inhibitor of Matrix Metalloproteinase-1 by Antibiotic Treatment in Acute Exacerbation of Chronic Bronchitis (만성 기관지염의 급성 악화에서 항생제 투여에 의한 유도객담 내 Matrix metalloproteinase와 Tissue inhibitor of matrix metalloproteinase의 변화)

  • Yoon, Hyoung-Kyu;Ahn, Joong-Hyun;Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.420-430
    • /
    • 2002
  • Background : Excessive extracellular matrix (ECM) deposition by airway inflammation is presumed to play an important role in the pathogenesis of worsening airflow obstruction (Ed- acceptable three-word noun) seen during acute exacerbations of chronic bronchitis. Although many proteases can cleave ECM molecules, matrix metalloproteinases (MMPs) and their inhibitors are likely to be the physiologically relevant mediators of ECM degradation. Objectives ; The purpose of this study was to demonstrate that antibiotic treatment can change airway MMPs and TIMP-1 concentrations/levels by controlling airway inflammation in acute exacerbation of chronic bronchitis. Methods : We studied 40 patients, all of whom had an acute exacerbation of chronic bronchitis. The patients were treated with two different antibiotics, moxifloxacin and clarithromycin, in a double-blind manner for 7 days. Sputum samples were induced and collected before and after antibiotic therapy. We measured the sputum concentration of MMP-1,-9, TIMP-1, IL-8 and secretory leukocyte proteinase inhibitor (SLPI) in sputum supernatants by ELISA method. Results : There was no difference after antibiotic treatment in the sputum concentrations of MMP-1,-9, TIMP-1, IL-8 and SLPI between the patients treated with moxifloxacin and those treated with clarithromycin. But the sputum concentrations of TIMP-1, and SLPI, and the TIMP-1/MMP-1 ratio were significantly reduced by the antibiotic therapy. There were significant positive correlations between sputum TIMP-1 levels and IL-8 levels (p<0.01, r=0.751), and between the sputum TIMP-1/MMP-1 ratio and IL-8 levels (p<0.01, r=0.752). The sputum SLPI levels were significantly elevated by antibiotic treatment and were negatively correlated with sputum TIMP-1 levels (p<0.01, r=-0.496) and TIMP-1/MMP-1 levels (p<0.01, r=-0.456). Conclusion : The study shows that the worsening of airway inflammation in acute exacerbation of chronic bronchitis is associated with an imbalance between the concentrations/levels of TIMP-1 and MMPs. Antibiotic treatment can prevent progression of airway narrowing in acute exacerbation of chronic bronchitis by modulation of the protease and anti-protease imbalance.