• Title/Summary/Keyword: 박리파괴

Search Result 140, Processing Time 0.021 seconds

한국 동굴의 환경 파괴 분석

  • 김추윤
    • Proceedings of the Speleological Society Conference
    • /
    • 1994.11a
    • /
    • pp.86-87
    • /
    • 1994
  • 동굴의 파괴현상은 크게 퇴적물공해와 환경공해의 두가지로 대별되는데 그중 퇴적물공해는 파손공해, 녹색공해, 그리고 흑색공해, 박리공해 등의 네가지로 구분된다. 즉 파손공해는 시설작업 또는 관광객들의 출입통로 개척을 위한 개발작업으로 동굴퇴적물들이 파손, 오손되는 경우를 말한다. 그리고 녹색공해는 조도, 온도, 습도와 관련된 하등식물의 공해이고 흑색공해는 탄소분의 공해인 경우도 있고 아니면 균류의 패층작용에 의한 경우도 있다.(중략)

  • PDF

Static and Fatigue Behavior Characteristics of Reinforced Concrete Beams Strengthened with CFRP Plate (CFRP Plate로 보강된 철근콘크리트 보의 정적 및 피로 거동 특성)

  • Kim, Kwang-Soo;Kim, Jin-Yul;Kim, Sung-Hu;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.141-148
    • /
    • 2008
  • In the recent construction industry, Carbon Fiber Reinforced Polymers(CFRPs) have been highly considered as innovative strengthening materials for civil structures due to their superior material properties. This paper is to offer design data and strengthening efficiency of reinforced concrete beams strengthened with CFRP Plate. Static tests were carried out to evaluate failure modes and strengthening capacity. Displacements and strains of steel and CFRP plates were obtained and analyzed through a series of fatigue tests. Also, Those evaluated the energy dissipation. Results of the tests showed increase in strengthening ratios caused debonding failure at the end of beams. For the beams wrapped with CFRP sheets around the end of the plates, debonding failure mode that was induced from flexural cracks was indicated. Through the fatigue tests, it was observed that displacements, strains of steel and CFRP plates converged into certain values. It is also proved that the beams strengthened with CFRP plates are able to resist fatigue loading under serviceability.

Crack Growth and Debonding Behaviors of the Pre-cracked RC Beams Repaired with Carbon Fiber Sheets (사전균열로 손상된 RC 보의 탄소섬유시트 보수 후의 균열성장 및 박락거동)

  • Kim, Chung Ho;Ko, Sin Woong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.121-129
    • /
    • 2006
  • This study look into the mechanisms of growth and magnification of the cracks and delamination in the pre-cracked RC beams repaired with carbon fiber sheets. The experimental parameters were loading type, loading speed and crack. In the experiments, it was confirmed that a failure of beams began with development and propagation of the stepped delamination in the below the loading point due to the rapid change of shear force, but mechanisms of the failure were not influenced with loading type, loading speed and pre-cracks. Particularly, in the case of beams having the pre-cracks, growth of crack concentrated at the special crack below the loading point and led to failure of the beam by delamination due to magnification of crack.

An Experimental Study on the Shear Behavior of Reinforced Concrete Beams Strengthened with Slit Type Steel Plates (Slit형(形) 강판으로 보강(補强)한 철근콘크리트 보의 전단거동에 관한 실험연구)

  • Lee, Choon-Ho;Shim, Jong-Seok;Kwon, Ki-Hyuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • RC beam of existing structures often encounter shear problems for various reasons. The shear failure of RC beam is sudden and brittle. Strengthening technique jacketing with external bonding of steel plates(or CFRP and CFS) with epoxy is many use to in practice. This study presents test results on strengthening shear deficient RC beams by external bonding of slit type steel plates. Test parameters are width, interval, length, thickness and angle of slit in steel plates. The purpose was to evaluate the reinforcing effects, failure modes and shear capacities for RC beams of strengthened with various slit type steel plates. The test result confirmed that all slit steel plates improved the stiffness and strength of the specimens significantly. Failure modes of SV series and SD series showed shear fractures and flexure fractures at ultimate state respectively. SD series were ductile rather than SV series.

Adhesive Performance and Fracture Toughness Evaluation of FRP-Reinforced Laminated Plate (FRP 보강적층판의 접착성능 및 파괴인성평가)

  • Jung, Hong-Ju;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.868-875
    • /
    • 2015
  • In order to replace existing slit type steel plate on the wooden structure joint, the FRP-reinforced laminated plates were produced. Four types of FRP-reinforced laminated plates were produced according to the type of reinforcement and adhesive, and before applying to the joint, the adhesion performance test according to KSF 3021 and KSF 2160 and the Compact Tension (CT) type fracture toughness test specified in ASTM D5045-99 were carried out. As a result of adhesion performance test, all GFRP textile, GFRP sheet, and GFRP Textile-Sheet type FRP-reinforced laminated plates satisfied the requirement of soaking delamination percentage with smaller than 5% based on KS standard. However, aramid type specimen satisfied the standard as the soaking delamination percentage of 4.8% but it did not satisfied the standard as the water proof soaking delamination percentage of 70%. As a result of fracture toughness test, the volume ratio of reinforcement to timber became 23% so that the strength of FRP-reinforced laminated plates increased by two to four times in comparison to the control specimen. It was confirmed that the GFRP Textile-Sheet type specimen was most resistant to the fracture most since the ratio of stress intensity factor compared with that of the control increased to 61% owing to the parallel arrangement of glass fiber to the load. As a result of tensile shear strength test using FRP-reinforced laminated plates and nonmetal dowels, it is about 12% lower than metal connectors.

Fracture Characteristics of Ductile Fiber Reinforced Cement based Composites by Collision of Steel Projectile (비상체의 충돌에 의한 고인성 섬유보강 시멘트복합체의 파괴특성)

  • Nam, Jeong-Soo;Kim, Gyu-Yong;Kim, Hong-Seop;Kim, Jung-Hyun;Han, Sang-Hyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.92-100
    • /
    • 2015
  • The aim of this study is to evaluate the fracture characteristics of ductile fiber reinforced cement based composites with 1.5 volume ratio of polyvinyl alcohol and steel fiber by high velocity impact of steel projectile. We used gunpowder impact facility to evaluate the fracture characteristics of ductile fiber reinforced cement based composites by collision of steel projectile, and the impact velocity was from about 150 to 1,000m/s. The results of evaluation on the fracture characteristics of ductile fiber reinforced cement based composites were penetration grade, which is the kinetic energy more than three times of no-fiber reinforced specimen (Plain). In addition, ductile fiber reinforced cement based composites did not occurred critical damage other than the debris. In the case of mass loss, Plain specimen was proportional to kinetic energy of steel projectile, while ductile fiber reinforced cement based composites was not significantly affected by kinetic energy of steel projectile. In particular, this tendency had a close relationship with the fracture characteristics of back side of specimens, and the scabbing inhibiting efficiency of PVA specimen was higher than S specimen. In the results of verifying relationship between front and back side calculated by local damage, scabbing occurred at the region close to the back side in the ductile fiber reinforced cement based composites unlike Plain specimen. Thus, in this study, we examined principal fracture behaviors of ductile fiber reinforced cement based composites under collision of steel projectile, and verified that impact resistance performance was improved as compared to Plain specimen.

Theoretical Analysis of Interface Debonding on the Strengthened RC Bridge Decks (성능향상된 RC 바닥판의 계면파괴 해석)

  • 오홍섭;심종성
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.668-676
    • /
    • 2002
  • Especially, when orthotropic material such as uni-dierectionally woven Carbon Fiber Sheet, resisting only the unidirectional tension, is used to strengthening bridge deck, the direction and width of the strengthening material should be considered very carefully. Thus, analysis of the failure characteristics and the premature failure mechanism of the strengthened decks based on the test results are required. In this study, the premature failure due to the interface debonding of strengthening material of the strengthened deck slab are inquired into failure mechanism through both experiments results and analyses with prototype strengthened deck specimens using carbon fiber sheet. From the test results, interface debonding of strengthening material is occured at the crack face

Effect of Loading Conditions on the Fractrue Behavior in $\textrm{SiC}_{p}$/Al Alloy Composite ($\textrm{SiC}_{p}$/Al합금 복합재료의 파괴거동에 미치는 부하조건의 영향)

  • An, Haeng-Geun
    • Korean Journal of Materials Research
    • /
    • v.7 no.11
    • /
    • pp.974-980
    • /
    • 1997
  • SiC$_{p}$/AI 합금 복합재료에 있어서 동적 및 정적파괴인성시험을 실시하고 파괴거동에 미치는 부하조건의 영향을 검토하였다. 동적파괴인성시험은 CAI시스템을 이용하여 1.5m/sec의 부하속도로 실시하였고, 정적파괴인성시험은 만능시험기를 이용하여 0.3 mm/min의 부하속도로 실시하였다. 또한 파괴과정을 명확히 해석하기 위하여 동적부하조건에 대해서는 stop block법을, 정적부하조건에 대해서는 복수시험편법을 이용하였다. 균열의 발생 및 성장은 부하조건에 의해 크게 영향을 받으며, 변위량에 대한 균열의 발생은 정적부하조건에서 더 빨리 일어나고, 균열의 성장은 동적부하조건에서 더 급격하다. 또한 부하조건은 파괴의 형태에도 크게 영향을 미치며, 동적부하조건하에서는 정적부하조건하에 비하여 균열이 입자부분(입자의 파단 또는 박리)을통과해 가는 경향이 크고 비교적 많은 편향을 반복해서 진행해 가지 때문에 파괴인성치도 크다.다.

  • PDF

A Study on the Behavior of the Adhesive Failure of RC Beams Strengthened by Carbon Fiber Sheet (탄소섬유쉬트로 보강된 철근콘크리트보의 부착파괴거동에 관한 실험적 연구)

  • 박칠림;황진석;박형철;백명종
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.6
    • /
    • pp.157-164
    • /
    • 1997
  • 최근 손상된 구조물에 탄소섬유쉬트 보강공법이 많이 사용되고 있다. 탄소섬유쉬트 보강에 따른 휨내력의 증진이 이루어지기 위해서는 보와 탄소섬유쉬트의 일체거동이 이루어져야 하며, 쉬트단부에서 부착파괴가 발생하지 않아야 한다. 따라서 이번 실험에서는 탄소섬유쉬트의 보강매수에 따른 부착파괴의 거동을 살펴보았다. 전시험체에서 부착파괴가 발생하였으며 부착파괴가 발생한 하중의 크기는 보강매수에 관계없이 비슷하였다. 부착파괴의 거동은 순수부착파괴와 피복박리파괴로 구분될 수 있었으며 부착응력은 단부에서 집중현상이 나타났고 집중된 응력의 크기는 15.39~41.42kg/$\textrm{cm}^2$로 나타났다. 정착길이내의 평균부착응력은 6.85~8.99kg/$\textrm{cm}^2$으로서 평균 7.38kg/$\textrm{cm}^2$이고 이 값은 이론치인 6.19kg/$\textrm{cm}^2$보다 약간 높으며 설계부착응력인 6kg/$\textrm{cm}^2$에 부합되는 것으로 나타났다. 따라서 설계부착응력 6kg/$\textrm{cm}^2$은 정착길이의 설계시 합리적 값으로 평가되었다.

Adhesion Improvement of Polymer/Metal Interface Produced by Surface Treatment (표면 처리에 의한 고분자/금속 계면에서의 접착력 향상)

  • 박수진;서민강;김학용;이덕래
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2002.04a
    • /
    • pp.489-492
    • /
    • 2002
  • 고분자/금속 복합재료는 현대 전자산업에 중요한 역할을 하고 있다. 그러나 이들간의 계면은 고분자의 수축 또는 계면 안정성의 저하로 인하여 박리가 일어나게 된다. 즉, 계면의 접합이 떨어지게 되면 전기 화학적인 반응이 계면에서 발생하여 드러난 금속부위는 산화되고 산소가 환원될 때 발생하는 OH기와 같은 라디칼들에 의해 금속과 고분자 사이의 결합이 파괴되어 금속표면으로부터의 고분자의 박리가 발생한다. (중략)

  • PDF