• Title/Summary/Keyword: 바이프리즘

Search Result 6, Processing Time 0.025 seconds

Developement of Scope for Military Rangefinder Using Schmidt Prism and Biprism Theory of Optometric Instrument (안광학기기에 사용되는 바이프리즘원리와 슈미트 프리즘을 이용한 군사 거리측정기용 스코프 개발)

  • Cha, Jung-Won;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.167-175
    • /
    • 2015
  • Purpose: The new-type rangefinder, which is using the biprism principle, is introduced to develop the range finder which can be easily carried by soldiers, and in order to realize those technologies specifically, we try to develop a scope for military rangefinder by doing optical design which can secure enough space to move the biprism. Methods: After setting up the verious initial condition to realize two kinds of goals, that are the securement of enough space to move the biprism and the easy-exchangeability of two kinds of biprisms, and then the optical system was optimized by using optical design program CodeV in order to minimize the finite ray aberrations. Results: We designed the biprism housing to makes it possible to swap the two kinds of biprisms. It was appeared that the Schmidt prism is suitable as erecting prism which can make sure the space to move the biprism. 16.5 mm was good for the face length of Schmidt prism. The optical system with a Schmidt prism and a biprism was designed, and the finite ray aberrations was minimized. Conclusions: We developed a 5X scope for an optical rangefinder using a biprism and a Schmidt prism with 16.5 mm face length. This scope is valid for the optical system which has the effective field angle of ${\pm}3.6^{\circ}$, and the finite ray aberrations are well controlled within the ${\pm}8.95^{\prime}$.

Study on Golf Range Finder by using Biprism Theory of Keratometer (케라토미터의 바이프리즘 원리를 이용한 골프거리측정기에 관한 연구)

  • Cha, Jung-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.495-501
    • /
    • 2013
  • Purpose: This study was to develop golf range finder which could measure exact distance from golfer to flag by using telescope and biprism. Methods: Golf range finder was made that included telescope and biprism which could move in the telescope, and an accuracy of the range finder was analyzed in distance range 20~200 m. Results: An equation was made for measuring distance which was related at position of biprism, and we could measure distance successfully by using developed golf range finder. Biprism of 2 ${\Delta}$ was useful to measure in short distance but it had bad accuracy in long distance, and 0.5 ${\Delta}$ was more useful in long distance. Image got worse when the biprism approch to focal point of objective lens for measurement in long distance, so we developed multi-layer biprism to prevent the weak point. Conclusions: Image stabilization by biprism for measuring distance was confirmed. Even if hand was moving, the distance could be measured well by using biprism, and we could find that the induced equation for distance measurement was useful. We found that multi-layer biprism, which is was new developed, was more useful than general biprism when the biprism approched to focal point of objective lens for measurement in long distance.

Measurement of GMAW Bead Geometry Using Biprism Stereo Vision Sensor (바이프리즘 스테레오 시각 센서를 이용한 GMA 용접 비드의 3차원 형상 측정)

  • 이지혜;이두현;유중돈
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.200-207
    • /
    • 2001
  • Three-diemnsional bead profile was measured using the biprism stereo vision sensor in GMAW, which consists of an optical filter, biprism and CCD camera. Since single CCD camera is used, this system has various advantages over the conventional stereo vision system using two cameras such as finding the corresponding points along the horizontal scanline. In this wort, the biprism stereo vision sensor was designed for the GMAW, and the linear calibration method was proposed to determine the prism and camera parameters. Image processing techniques were employed to find the corresponding point along the pool boundary. The ism-intensity contour corresponding to the pool boundary was found in the pixel order and the filter-based matching algorithm was used to refine the corresponding points in the subpixel order. Predicted bead dimensions were in broad agreements with the measured results under the conditions of spray mode and humping bead.

  • PDF

Beam Rotator of Optical System Based on Multi-Beam (다중 광선을 이용한 광 시스템의 광선 회전기)

  • 이정현;한창수;김수현;곽윤근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.194-201
    • /
    • 1998
  • The beam rotating actuator has been developed. It can be utilized to improve the data transfer rate for the optical disk systems, Newly developed laser beam rotating actuator is applied to put multi-beam spots on more than one track on the optical disk simultaneously. The beam rotating actuator is made of piezoelectric ceramic bimorph as the form of cantilever, Piezoelectric actuators with high resolution, high stiffness and fast frequency response are widely assembled in micropositioning applications. Therefore, the actuator has above 50Hz natural frequency. Beam array is rotated using the dove prism in the end of beamrotator. The dynamic equation of beam rotating actuator is derived theoretically. The actuator is designed on the ground of this analysis. The performance of the beam rotating actuator is verified as the dynamics frequency performance is measured using the dynamic analyzer and sensor.

  • PDF

Miniature Biochip Fluorescence Detection System with Spatial Separation of Fluorescence from Excitation Light (형광과 여기광을 공간적으로 분리하는 바이오칩용 소형 형광측정시스템)

  • Kim Ho-seong;Choi Jea-ho;Park Ju-han;Lee Kook-nyung;Kim Yong-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.378-383
    • /
    • 2005
  • We report the development of miniature fluorescence detection systems that employ miniature prism, mirrors and low coat CCD camera to detect the fluorescence emitted from 40 fluorescently-labeled protein patterns without scanner. This kind of miniature fluorescence detection system can be used in point of care. We introduce two systems, one uses prism+mirror block and the other uses prism and two mirrors. A large NA microscope eyepiece and low cost CCD camera are used. We fabricated protein chip containing multi-pattern BSA labeled with Cy5, using MEMS technology and modified the surface chemically to clean and to immobilize proteins. The measurements show that the combination of prism and mirrors can homogenize elliptical excitation light over the sample with higher optical efficiency, and increase the separation between excitation and fluorescence light at the CCD to give higher signal intensity and higher signal to noise ratio. The measurements also show that protein concentrations ranging from 10 ng/ml to 1000 ng/ml can be assayed with very small error. We believe that the proposed fluorescence detection system can be refined to build a commercially valuable hand-held or miniature detection device.