Using Design to Make Doffing of Personal Protective Equipment Safer for Healthcare Workers (의료종사자의 안전한 개인보호장비 탈의를 위한 공간 설계에 관한 연구)

  • Matic, Zorana;Oh, Yeinn;Lim, Lisa
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.3
    • /
    • pp.17-26
    • /
    • 2020
  • Purpose: This paper presents research evidence that the environmental design of the doffing area in a biocontainment unit (BCU) can have a measurable impact on increasing the safety of frontline healthcare workers (HCW) during doffing of high-level personal protective equipment (PPE), and proposes optimized biocontainment unit design. Methods: From 2016 to 2019, The SimTigrate Design Lab conducted 3 consecutive studies, focusing on ways in which the built environment may support or hinder safe doffing. In the first study, to identify the risky behaviors, we observed 56 simulation exercises with HCWs in 4 BCUs and 1 high-fidelity BCU mockup. In the second study, we tested the effectiveness of a redesigned doffing area on improving the HCWs performance and used simulation, observation, and rapid prototyping in 1 high-fidelity mockup of a doffing area. In a follow-up study, we used simulation and co-design with HCWs to optimize the design of a safer doffing area in a full-size pediatric BCU mock-up. Results: We identified 11 specific risky behaviors potentially leading to occupational injury, or contamination of the PPE, or of the environment. We developed design strategies to create a space for safer doffing. In the second study, in a redesigned doffing area, the overall performance of HCW improved, and we observed a significant decrease in the number of risky behaviors; some risky behaviors were eliminated. There was a significant decrease in physical and cognitive load for the HCWs. Finally, we propose an optimized layout of a BCU for a safer process of PPE doffing. Implications: The proposed BCU design supports better staff communication, efficiency, and automates safer behaviors. Our findings can be used to develop design guidelines for spaces where patients with other highly infectious diseases are treated when the safety of the patient-facing HCWs is of critical importance.

Correlation of Effective Dose and BMI in Radioiodine($^{131}I$) Therapy (방사성옥소($^{131}I$) 치료 시 유효선량과 체질량지수의 상관관계)

  • Shin, Gyoo-Seul;Kim, Gun-Jae;Dong, Kyung-Rae;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Purpose : The aim of this study was to predict radiation dose at 1 meter with BMI(body mass index) in thyroid cancer patients treated with radio-iodine and provide the efficient guideline in the management of patients. Methods : 140 patients from thyroidectomy for thyroid cancer were enrolled. All subjects under went 150 mCi radio-iodine therapy and performed whole body scan 1 week later. BMI(weight divided by square of height) was calculated to evaluate the amount of fatty tissue indirectly. The radiation dose at 1 meter was measured initially and on 2nd days. the relation of values with BMI were analyzed statically. As for the method of statistical analysis, using Med calc Version 9,2,2,0 Program. Results : (1) The initial effective dose was inversely correlated with the BMI. Significance level was 0.0004. (2) We obtained the following formula from the data of initial effective dose and BMI: Y = -30.91X + 350.4(${\mu}Sv/h$)(Y: initial radiation dose, x: Group). (3) After 21.55 hours, than radiation dose was less than those recommended by ICRP or NRC in 53% of the population. Conclusion : Using BMI, the initial radiation dose and 2nd days dose can be predicted in thyroid cancer patients before radio-iodine therapy. It may be used for predicting the time of discharge and control the isolation room. We were able to predict the radiation exposure after discharge using this calculated value.

  • PDF