• 제목/요약/키워드: 바이오전극

Search Result 151, Processing Time 0.024 seconds

The Classification and Investigation of Smart Textile Sensors for Wearable Vital Signs Monitoring (웨어러블 생체신호 모니터링을 위한 스마트텍스타일센서의 분류 및 고찰)

  • Jang, Eunji;Cho, Gilsoo
    • Fashion & Textile Research Journal
    • /
    • v.21 no.6
    • /
    • pp.697-707
    • /
    • 2019
  • This review paper deals with materials, classification, and a current article investigation on smart textile sensors for wearable vital signs monitoring (WVSM). Smart textile sensors can lose electrical conductivity during vital signs monitoring when applying them to clothing. Because they should have to endure severe conditions (bending, folding, and distortion) when wearing. Imparting electrical conductivity for application is a critical consideration when manufacturing smart textile sensors. Smart textile sensors fabricate by utilizing electro-conductive materials such as metals, allotrope of carbon, and intrinsically conductive polymers (ICPs). It classifies as performance level, fabric structure, intrinsic/extrinsic modification, and sensing mechanism. The classification of smart textile sensors by sensing mechanism includes pressure/force sensors, strain sensors, electrodes, optical sensors, biosensors, and temperature/humidity sensors. In the previous study, pressure/force sensors perform well despite the small capacitance changes of 1-2 pF. Strain sensors work reliably at 1 ㏀/cm or lower. Electrodes require an electrical resistance of less than 10 Ω/cm. Optical sensors using plastic optical fibers (POF) coupled with light sources need light in-coupling efficiency values that are over 40%. Biosensors can quantify by wicking rate and/or colorimetry as the reactivity between the bioreceptor and transducer. Temperature/humidity sensors require actuating triggers that show the flap opening of shape memory polymer or with a color-changing time of thermochromic pigment lower than 17 seconds.

Detection of SNPs using electrical biased method on diamond FETs (다이아몬드 FETs에서 전기적 바이어스 방법을 이용한 단일염기 다형성(SNPs) 검출)

  • Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.190-195
    • /
    • 2015
  • The detection of single nucleotide polymorphisms (SNPs) caused of mutant or genetic diseases is important to diagnosis and medicine. There are many methods have been proposed to detect SNPs. However the detection of SNPs is difficulty, because the difference of energy between complementary DNA (cDMA) and SNPs is very small. In this work, we detect the SNPs using field-effect transistors (FETs) which based on the detection of negative charge of DNA. We bias -0.3 V on the drain-source electrode at the target DNA hybridization process. The efficiency of hybridization and the amplitude of signal decrease by repulsive force between negative charge of DNA and negative bias on the electrode. However, the sensitivity of SNPs increases about 5 times from 1.7 mV to 8.7 mV.

A Study on A Multi-Pulse Linear Predictive Filtering And Likelihood Ratio Test with Adaptive Threshold (멀티 펄스에 의한 선형 예측 필터링과 적응 임계값을 갖는 LRT의 연구)

  • Lee, Ki-Yong;Lee, Joo-Hun;Song, Iick-Ho;Ann, Sou-Guil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.20-29
    • /
    • 1991
  • A fundamental assumption in conventional linear predictive coding (LPC) analysis procedure is that the input to an all-pole vocal tract filter is white process. In the case of periodic inputs, however, a pitch bias error is introduced into the conventional LP coefficient. Multi-pulse (MP) LP analysis can reduce this bias, provided that an estimate of the excitation is available. Since the prediction error of conventional LP analysis can be modeled as the sum of an MP excitation sequence and a random noise sequence, we can view extracting MP sequences from the prediction error as a classical detection and estimation problem. In this paper, we propose an algorithm in which the locations and amplitudes of the MP sequences are first obtained by applying a likelihood ratio test (LRT) to the prediction error, and LP coefficients free of pitch bias are then obtained from the MP sequences. To verify the performance enhancement, we iterate the above procedure with adaptive threshold at each step.

  • PDF

MOF-based membrane encapsulated ZnO nanowires for H2 selectivity (MOF 기반 멤브레인 기능화된 ZnO 나노선의 수소 가스 선택성)

  • Kim, Jae-Hun;Lee, Jae-Hyeong;Kim, Jin-Yeong;Kim, Sang-Seop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.106-106
    • /
    • 2017
  • 가스센서는 사내 및 산업 환경에서의 유독성 또는 폭발성 가스 검출, 환경 모니터링, 질병 진단 등 매우 다양한 응용분야에서 큰 관심을 가지고 있다. 반도체 금속산화물(SMOs) 기반의 센서 분야에서는 이들의 감도 및 선택성을 향상시키기 위해 많은 노력을 기울이고 있다. 이는 센서의 선택성을 부여하게 되면 다양한 가스들이 존재하는 환경에서도 검출자가 원하는 가스만의 응답을 얻을 수 있기 때문이다. 본 연구에서는 MOF(Metal-Organic Framwork) 기반 멤브레인으로 ZIF-8(Zeolitic Imidazolate Frameworks 구조들 중 하나) 멤브레인 쉘 층을 이용하여 ZnO 나노선에 형성하였다. ZnO 나노선은 VLS공정 (Vapor-Liquid-Solid)을 이용하여 패턴된 전극을 갖는 $SiO_2$-grown Si 웨이퍼 상에 성장되었고, 성장된 ZnO 나노선은 2-methyl imidazole과 methanol이 포함된 고용체에 넣고 폐쇄된 압력용기 속에서 가열시켜 얻게 된다. 이렇게 얻어진 ZIF-8@ZnO 나노선의 ZIF-8 멤브레인은 분자 체 구조(molecular sieving structure)를 갖게 되며, 이들의 pore 크기는 약 $3.4{\AA}$을 갖는다. 따라서 이보다 더 큰 동적 직경을(kinetic diameter) 갖는 가스 종은 이 멤브레인을 통과할 수 없음을 나타내므로 제작된 시편은 $H_2$(kinetic diameter : $2.89{\AA}$), $C_7H_8$(kinetic diameter : $5.92{\AA}$), 그리고 $C_6H_6$(kinetic diameter : $5.27{\AA}$) 가스들을 각각 사용함으로써 ZIF-8@ZnO 나노선의 센서 특성을 조사했으며, 보다 정확한 비교를 위해 순수한 ZnO 나노선 역시 동일한 조건에서 측정되었다. 결과를 통해, 수소 가스를 제외한 다른 가스들에 대해서는 반응을 하지 않고, 오직 수소 가스에 대해서만 반응을 나타냈으며, 순수 ZnO 나노선의 수소 감응도보다 낮은 감응도를 나타내었다. 이는 멤브레인 쉘 층을 형성함으로써 ZnO 나노선의 표면적이 감소해 가스 분자와의 접촉점을 감소시키기 때문이라고 판단된다. 이와 같은 MOF 멤브레인의 캡슐화 전략은 가스센서뿐 아니라 바이오 센서 및 광촉매 등과 같은 이온 선택성을 필요로 하는 다양한 응용분야에 적용될 수 있을 것으로 기대된다.

  • PDF

Synthesis of Electroactive Polythiophene Derivatives and Its Application for Biointerface (I) (전기적 활성을 갖는 폴리티오펜 유도체들의 합성과 생체계면에의 응용 (I))

  • 정선형;배진영;김지흥;정동준
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.28-36
    • /
    • 2002
  • In this study, we synthesized novel thiophene derivatives by the protection of the carboxyl group of 3-thiophene acetic acid with differently substituted benzyl groups. While 3-thiophene acetic acid is not electro-polymerizable, the modified monomers can be easily electro-oxidized to form stable electroactive polymers. The protecting groups can be easily removed in the solid state and the desired reactive carboxyl group can be introduced on the polymer surface. SEM observations show that obtained polymer films show a very good film surface and homogeneous morphology on the Pt electrode. After introduction of macromonomer, FT-IR spectrum shows new absorption bands at 1650 and $1550 cm^{-1}$, which is consistent with the formation of an amide bond. Electroactivity measurements were examined by cyclic voltammogram(CV). These polymers showed the characteristic electrochemical behavior of poly(3-alkylthiophene)s with reversible redox transition in the range of 0.7-0.9 V.

Study of Enzyme Immobilization on Composite of CTA and PCL Membrane for Biosensor (바이오센서용 CTA와 PCL 혼합막에의 효소고정화 기법의 개발)

  • 홍성현;김태진
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.468-474
    • /
    • 1995
  • The disposable glucose bio-sensor using composite of CTA and PCL membrane was developed for measurement of glucose. The most effective membrane was composed of CTA/PCL(80/20, w/w) and glutaraldehyde one-step immobilization method ($10{\mu}m$ thickness) for glucose sensor gave the best result among various methods, considering oxygen permeability and electronic sensitivity. A scanning electron micrograph of the cross-section of a typical asymmetric CTA/PCL composite membrane showed that the membrane fused with a dense layer covered with a GOD-glutaraldehyde. Glucose oxidase immoblilized on the membrane showed the linearity between difference of absolute amperometric values and glucose concentrations within 7mM when the GOD immobilized electrode was used. About 35% of activity was remained after 8 days when the tyrosinase was immobilized on CTA/PCL (80/20) membrane.

  • PDF

Preparation and Characteristics of a Single-layer PVA Laminated CTA/PCL Membrane for Oxygen Biosensor Electrode (산소센서용 CTA/PCL 효소고정화막과 반투막을 단일화한 PVA적층막의 제조 및 특성)

  • Seo, Jong-Won;Kim, Tae-Jin;Jeong, Yong-Seob;Yoon, Jeong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.247-252
    • /
    • 1999
  • The oxygen electrode of a biosensor needs enzyme immobilized membrane and a dialysis membrane to measure the oxygen concentration that remains after an enzyme reacts with its substrate. Accodingly, a single-layer PVA laminated CTA/PCL membrane was developed as an oxygen biosensor electrode. The enzymes were immobilized on a cellulose triacetate/polycarprolactone membrane using the 1,1'-carbonyl diimidazole(CDI) method, and then laminated with polyvinyl alcohol, aldehyde and acid. The alcohol oxidase and PVA laminated CTA/PCL membrane was tested with various concentration of enzyme substrates using a Yellow Springs Instrument(YSI) oxygen sensor. Under 5-10mmol substrates produced $0.37{\sim}0.83{\mu}A$(r=0.995) currents, and ater 8 weeks the glucose oxidase activity remained at about 56%, while the other activities remained very low. A SEM indicated a smooth surface and tightly attached PVA on the enzyme-immobilized CTA/PCL membranes.

  • PDF

Epitaxial growth of high-temperature ZnO thin films on sapphire substrate by sputtering (마그네트론 스퍼터링에 의한 사파이어 기판위에 고온에서의 ZnO박막의 에피성장)

  • Kim, Young-Yi;Ahn, Cheol-Hyoun;Kang, Si-Woo;Kong, Bo-Hyun;Cho, Hyung-Koun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.151-151
    • /
    • 2007
  • 최근에 에피 성장된 ZnO는 UV-LED, 화학적-바이오센서와 투명전도 전극에 많은 관심을 받고 있다. 고 품질의 ZnO는 Metal-organic chemical vapor deposition(MOCVD), Pulsed laser deposition(PLD), molecular beam epitaxy(MBE), 그리고 마그네트론 스퍼터링법에 의해 성장이 이루어지고 있다. 대부분의 ZnO는 사파이어, 싫리콘과 같은 이종 기판 위에 성장되고 있으며, Heteroepitaxy로 성장된 ZnO 박막은 기판과 박막사이의 격자상수, 열팽창계수 차이로 인해 높은 결함 밀도를 보이고 있다. 이러한 문제점은 광전자 소자 응용에 있어 여러 가지 문제점을 야기 시킨다. 이와 같은 문제점을 해결하기 위해 박막과 기판사이에 저온 버퍼층을 사용하거나 같은 물질의 버퍼층을 사용하여 결할 밀도를 감소시키고, 높은 결정성을 가진 ZnO 박막을 성장시킨 결과들이 많이 보고되어지고 있다. 본 연구에서는 마그네트론 스퍼터링 법으로 저온 버퍼층 성장 없이 성장온도 만을 달리 하여 고품질의 ZnO 박막을 성장시켰다. ZnO 박막은 c-sapphire 기판위에 ZnO(99.9999%)의 타겟을 사용하여 $600{\sim}800^{\circ}C$ 온도에서 성장시켰고, 스퍼터링 가스로는 아르곤과 산소를 2:1 비율로 혼합하여 15mtorr의 압력에서 성장하였다. 이렇게 성장시킨 ZnO 박막은 Transmission Electron Microscopy (TEM), High-Resolution X-ray Diffraction (HRXRD), Low-temperature PL, 그리고 Atomic Force Microscopy (AFM)로 특성을 분석 하였다. ZnO 박막은 HRXRD (002) 면의 $\omega$-rocking curve운석 결과, $0.083^{\circ}$의 작은 FEHM을 얻었고, (102) 면의 $\varphi$-sacn을 통해 온도가 증가함에 따라 향상된 6-fold을 확인함으로새 에피성장됨을 알 수 있었다. 또한 TEM분석을 통해 $800^{\circ}C$에서 성장된 박막은 $6.7{\times}10^9/cm^2$의 전위밀도를 얻을 수 있었다.

  • PDF

Analysis for explosives in contaminated soil using the electrochemical method (폭발물 오염토양에서 전기화학법을 이용한 RDX 흔적량의 분석)

  • Ly, Suw Young
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Cyclic voltammetry (CV) and square wave stripping voltammetry (SW) analysis of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) using the double-stranded ds calf thymus (DNA) mixed in carbon nanotube paste electrode (PE) were provided. The optimum analytical conditions were determined and the peak potential was 0.2 V vs. Ag/AgCl. The linear working ranges of CV (50-75 ug/L) and SW (5-80 ng/L) were obtained. The precisions of RSD in the 10 ug/L was 0.086% (n=15) and the detection limit was 0.65 ng/L ($2.92{\times}10^{-12}M$) (S/N=3) with 300 s adsorption time at the optimum condition. The method was used to determine the presence of explosive chemicals in contaminated soil samples.

Effect of Carbon Dioxide in Fuel on the Performance of PEMFC (연료중의 이산화탄소 불순물에 의한 고분자전해질연료전지의 성능변화 연구)

  • Seo, Jung-Geun;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.42-46
    • /
    • 2008
  • Even though fuel cell have high efficiency when pure hydrogen from gas tank is used as a fuel source, it is more beneficial to generate hydrogen from city gas (mainly methane) in residential application such as domestic or office environments. Thus hydrogen is generated by reforming process using hydrocarbon. Unfortunately, the reforming process for hydrogen production is accompanied with unavoidable impurities. Impurities such as CO, $CO_2$, $H_2S$, $NH_3$, $CH_4$, and $CH_4$ in hydrogen could cause negative effects on fuel cell performance. Those effects are kinetic losses due to poisoning of the electrode catalysts, ohmic losses due to proton conductivity reduction including membrane and catalyst ionomer layers, and mass transport losses due to degrading catalyst layer structure and hydrophobic property. Hydrogen produced from reformer eventually contains around 73% of $H_2$, 20% or less of $CO_2$, 5.8% of less of $N_2$, or 2% less of $CH_4$, and 10ppm or less of CO. This study is aimed at investigating the effect of carbon dioxide on fuel cell performance. The performance of PEM fuel cell was investigated using current vs. potential experiment, long run(10 hr) test, and electrochemical impedance measurement when the concentrations of carbon dioxide were 10%, 20% and 30%. Also, the concentration of impurity supplied to the fuel cell was verified by gas chromatography(GC).