• Title/Summary/Keyword: 바륨

Search Result 217, Processing Time 0.03 seconds

A study on development of CRM by means of XRF analysis for fine ceramic ($BaTiO_3$) (티탄산바륨 소재의 XRF 분석용 CRM 개발에 관한 연구)

  • Kim, Young Man;Jeong, Chan Yee;Lim, Chang Ho;Song, Taek Yong;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.382-391
    • /
    • 1996
  • In this study, 12 different chemical species of fine ceramic($BaTiO_3$) were synthesized as the standard materials for the fast and accurate measurements of X-ray fluorescence spectrometry. Samples were diluted to sixteen times with the filling compound ($Li_2B_4O_7+LiBO_2$) in order to remove the matrix effect, and to get the convenient storage and homogeneity of ingredients. The matrix effects among the ingredients were corrected by the empirical coefficient method based on the Lucas-Tooth and Price model. The standard curve on 12 standard materials containing 15 elements were obtained by using X-ray fluorescence spectrometry at three different laboratories. The correlation factors of BaO, PbO, SrO, $Fe_2O_3$, $La_2O_3$, $SnO_2$, ZnO, $ZrO_2$, CaO indicated the relati vely good agreement over 0.995 among the three different laboratories. $SiO_2$ and $Al_2O_3$ showed the poor linearity because of their low fluorescence intensities.

  • PDF

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Composition Classification of Korea Ancient Glasses by Using Raman Spectroscopy (라만분광분석법을 이용한 한국 고대 유리의 조성 분류)

  • Sim, Woo Seok;Kim, Eun A;Lim, Soo Yeong;Kim, Hyung Min;Kim, Gyu Ho
    • Journal of Conservation Science
    • /
    • v.38 no.2
    • /
    • pp.117-123
    • /
    • 2022
  • In this study, investigated the possibility of quantitatively and qualitatively analyzing Korean ancient glasses via Raman Spectroscopy. We subjected four categories of Korean traditional glasses, namely, lead-BaO, lead, potash, and soda glasses (3, 3, 10, and 10 pieces, respectively), to this analytical technique. The results showed significant differences between the stretching and bending Raman vibration regions corresponding to these different Korean ancient glass types. Specifically, the stretching vibration regions corresponding to lead-BaO and lead glasses showed peaks at 1040 and 1000 cm-1, respectively; the stretching vibration region of normal glass appears at 1100 cm-1. The bending vibration regions corresponding to potash and soda glass showed Raman peaks at 490 and 560 cm-1, respectively. Furthermore, the Raman spectra of the lead and lead-BaO glasses showed red shifts, which depended on the amount of PbO present. Thus, our findings highlighted the possibility of quantitatively determining the amount of PbO, a major component of lead glasses, via Raman Spectroscopy.

Verification of the Protective Effect of Functional Shielding Cream for the Prevention of X-ray Low-dose Exposure (X-ray 저선량 피폭방지를 위한 기능성 차폐크림의 방어 효과 검증)

  • Seon-Chil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.497-506
    • /
    • 2023
  • In the case of radiation workers in medical institutions, radiation exposure is made for patient protection and accurate procedures, so they have a problem of low dose exposure. Low-dose radiation exposure occurs mainly in parts of the body other than the Apron area, and the most frequent place is the skin of the back of the hand. In particular, since the medical personnel's hands require senses and fine movements during the procedure, they are defenseless in the radiation exposure area and are at risk of exposure. It can solve the problem of shielding such as lead gloves, and it is difficult to use by suggesting the activity of the hand during the procedure. To solve this problem, a shielding cream capable of obtaining a functional radiation protection effect was developed and its shielding performance was compared with lead equivalent of 0.1 mmPb. In the process of manufacturing shielding cream, the shielding performance was improved by adding a defoaming process to reduce air holes to increase the density of the cream. Therefore, the shielding cream using barium sulfate as the main material has a lower shielding rate than the lead plate, and in the realm of effective energy, it is 59%, At high effective energy, a difference of about 37% was shown, indicating that there is a functional radiation protection effect. The advantage is that it can be used directly on the skin, and it is considered that it can be used before wearing surgical gloves and has a permanent protective effect.

Quantification of sulfur from organic and inorganic materials for determination of 35C (35C 측정을 위한 유기물과 무기물에서 황의 정량)

  • Lee, H.N.;Kang, S.H.;Song, B.C.;Sohn, S.C.;Jee, K.Y.
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.186-190
    • /
    • 2009
  • The oxidation studies of a sulfur to a sulfate ion by various oxyhalide oxidants in organic (thiourea, methionine) and inorganic (sulfate, thiophosphate) compounds were carried out in an acidic solution. The optimized result of the oxidation reaction was obtained when a bromate compound (${BrO_3}^-$) as an oxidant and a 3 M $HNO_3$ solvent were used. The chemical yield for the oxidation of the organic and inorganic sulfur compounds to a sulfate ion was monitored as 80% for thiophosphate, 87% for methionine, and 100% for thiourea and sulfate within 5% RSD. The oxidations of thiourea required at least 1.6 equivalents of the bromate in an acidic solution. In the case of the oxidation of methionine and thiophosphate, the oxidation yields were above 80% if the bromate was used at 20 times higher than that of the substrates. The sulfate ion was quantitatively measured by using a GPC counting of $^{35}S$ followed by precipitates of $BaSO_4$. A quenching correction curve for the $^{35}S$ counting was obtained to use the difference via the precipitate weight result.

Effect of Organic Processing Parameters in Non-aqueous Tape-casting on Dispersion Stability of Barium Titanate-Borosilicate Glass Based Suspensions (비수계 테잎성형공정의 유기공정변수의 변화에 따른 티탄산바륨-붕규산염유리계 현탁액의 분산안정성)

  • Yeo, Jeong-Gu;Choi, Sung-Churl
    • Korean Journal of Materials Research
    • /
    • v.13 no.11
    • /
    • pp.725-731
    • /
    • 2003
  • The effect of organic processing parameters on the dispersion stability of the BaTiO$_3$-based dielectric particles and borosilicate glass particulate suspensions was investigated in a system where organic solvents, dispersant, binder and modifier were used as processing additives in a low temperature cofired ceramic fabrication processes. Two- and three-component organic solvents were used to disperse ceramic particles and it was found the better stability in the particulate suspension prepared in a bi-solvent, which was consists of toluene and ethanol in a non-azeotropic composition. The addition amount of organic additives had a great impact on dispersion in the present investigation. The flow curves of the suspensions prepared with binder and modifier were fitted according to the power-law equation, which indicates that the internal structure of the suspension could be disturbed under the applied shear stress. Finally, the LTCC green tapes were successfully tape-cast based upon the optimum formulation of LTCC suspension and its microstructure was compared with that of the hard-agglomerates.

A Case of Primary Jejunal Adenocarcinoma in Children (소아에서 발생한 공장의 선암종 1례)

  • Cho, Myung-Hwan;Min, Yong-Sik;Park, Kyung-Bae;Park, Joon-Soo;Kim, Young-Chang
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.1 no.1
    • /
    • pp.125-132
    • /
    • 1998
  • Primary adenocarcinoma of the jejunum which accounts for only approximately 3% of all gastrointestinal tract malignancies, is distinctly unusual. The rarity and the non-specific symptoms of this cancer, which are the major factors contributing to its poor prognosis, make the diagnosis difficult. As the prognosis of primary adenocarcinoma of the jejunum, once metastasized, is poor, a greater awareness of the possibility of a jejunal cancer must accompany aggressive diagnostic and surgical procedure. We report our experience of a child with primary adenocarcinoma of the jejunum with a brief review of the literature.

  • PDF

Characteristics of NOx Reduction on NSR(NOx Storage and Reduction) Catalyst Supported by Ni, Ru-ZSM-5 Additives (Ni, Ru-ZSM-5를 첨가한 NSR 촉매의 NOx 정화 특성)

  • Choi, Byung-Chul;Lee, Choon-Hee;Jeong, Jong-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.105-111
    • /
    • 2007
  • In this study, we investigated the conversion performance of de-NOx catalyst for lean-burn natural gas engine. As a de-NOx catalyst, NOx storage reduction catalyst was composed of Pt, Pd and Rh with washcoat including Ba and Ni, Ru-ZSM-5. Ni, Ru-ZSM-5, which was regarded as a NOx direct decomposition catalyst, was made up of ion exchanged ZSM-5 by 5wt.% Ni or Ru. The performance of de-NOx catalyst was evaluated by NOx storage capacity and catalytic reduction in air/fuel, $\lambda=1.6$. The catalytic reaction was also observed when the added fuel was supplied to fuel rich atmosphere by fuel spike period of 5 seconds. The NOx conversion of the catalysts with Ni-ZSM-5 or Ru-ZSM-5 was mainly caused by the effect of NOx adsorption of Ba rather than the catalytic reduction of Ni, Ru-ZSM-5. Ni, Ru-ZSM-5 catalysts can not use for the NSR catalyst because they have quick process in thermal deactivation.

Development of EM Wave Absorbers for GHz Frequency (GHz 대역용 전파흡수체의 개발)

  • 문상현;신승재;김동일;송재만;최정현;김기만
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.17-22
    • /
    • 2004
  • We prepared EM wave absorbers by using recycled Ba and Sr ferrites for GHz frequency, and investigated the effects of carbon additions, thickness and preparation temperatures on their EM wave absorption properties. We clarified that it is very important to consider carbon amounts in Ba and Sr ferrites and preparation temperature for Ba and Sr ferrite EM wave absorbers with high quality. In this study, the developed a EM Wave absorber satisfying over 20 dB.

  • PDF

Properties of ba-ferrite Particles Synthesized by Molten Salt Method (용융염법으로 합성한 Ba-ferrite 입자의 특성)

  • 오영우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.545-550
    • /
    • 2000
  • In order to synthesize Ba-ferrite particles by molten salt method KCl and NaCl were added to basic composition to 50% by weight. X was varied from 0.0 to 1.0 to control the magnetic properties in $BaFe_{12-2x}$/ $Co_{x}$ / $Ti_{x}$ / $O_{19}$ and 1 mol% of $SiO_2$was added to control the aspect ratio of hexagonal platelets. And the effects of reaction temperatures were examined by varying the temperature from 85$0^{\circ}C$ to 120$0^{\circ}C$ with 5$0^{\circ}C$ intervals. Eutectic composition of NaCl and KCl lowered the crystallizing temperature of Ba-ferrite in molten salts than using KCl and NaCl separatly. The morphology of resulting Ba-ferrite particles was clearly hexagonal-shaped plates. $H_{c}$ and $M_{r}$ were decreased when F $e^{3+}$ was substitued with $Co^{2+}$ and $Ti^{4+}$ from x=0 to x=1.0 in $BaFe_{12-2x}$/ $Co_{x}$ / $Ti_{x}$ / $O_{19}$ . Adding 1mol% $SiO_2$in molten salt method increased the size but shortened c-axis of the hexagonal ferrites and this result is an opposite phenomenon compared with the result in solid-statge reaction.n.ion.n.

  • PDF