• Title/Summary/Keyword: 바닥 구조

Search Result 949, Processing Time 0.025 seconds

실내공기질 향상을 위한 환경친화형 바닥공조시스템

  • 조동우
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.32-40
    • /
    • 2004
  • 바닥공조시스템(underfloor air distribution system)은 건물 내에서 공기흐름을 바닥을 통해 조절하는 방식으로 전통적인 천장공조 방식을 대체할 새로운 시스템으로 평가받고 있다. 일반적으로 바닥 공조시스템은 공조기 등에서 송풍되는 공조공기가 억세스 플로어 하부의 바닥공간으로 전달되고 바닥급기구를 통해 실내로 송풍되는 구조를 이루고 있다. 바닥공조시스템의 이점은 전통적인 천장공조 방식에 비해 실내공기의 질(IAQ)이 향상되며 에너지의 절감이 가능하다는 점을 들 수 있다. (중략)

  • PDF

Evaluation on Static Behavior of Long Span Prestressed Concrete Deck (장지간 프리스트레스트 콘크리트 바닥판의 정적 거동 평가)

  • Joo, Sanghoon;Chung, Chulhun;Lee, Hanjoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.969-977
    • /
    • 2016
  • In this paper, the static load test of long span PSC deck used in the twin steel plate girder bridge was conducted. To evaluate the structural behavior of long span deck, longitudinally sufficient length of deck is needed, but it is difficult to test the full-scale long span deck due to limit of transportation, setting and laboratory space. Therefore, this study proposed a method to apply longitudinal stiffness of the full-scale deck to the test specimen of longitudinally short length, and it was reinforced with the steel beam. The failure behavior and structural performance of the long span deck were evaluated by the proposed test specimen deck.

Fatigue Performance of Precast Decks using Ribbed Loop Joints in a Two-Girder Continuous Composite Bridge (2거더 연속합성형교 요철형 루프이음 프리캐스트 바닥판의 피로성능)

  • Lee, Han-Joo;Yeo, Woon-Young;Shin, Dong-Ho;Kim, In-Gyu;Park, Se-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2019
  • Structural performance and serviceability of precast deck system are mostly determined by connection details between precast decks. Particularly, since the bridge deck is under repeated loads such as traffic loads, fatigue behavior and performance of joints should be investigated. In this study, a two-girder continuous composite bridge specimen was fabricated using the asymmetric ribbed loop joints, and static and fatigue load tests were conducted to evaluate the structural behavior and the crack pattern of the bridge deck. From the test results, the proposed precast deck system resulted in sufficient fatigue performance and failure strength. Therefore, the proposed precast deck system can be applied to the connection part of precast decks effectively.

Service and Ultimate Load Behavior of Bridge Deck Reinforced with GFRP Rebars (GFRP 보강근으로 보강된 교량 바닥판의 성능과 사용성에 관한 실험연구)

  • Yu, Young Jun;Park, Young Hwan;Park, Ji Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.719-727
    • /
    • 2008
  • The tensile and bond performance of GFRP rebar are different from those of conventional steel reinforcement. It requires some studies on concrete members reinforced with GFRP reinforcing bars to apply it to concrete structures. GFRP has some advantages such as high specific strength, low weight, non-corrosive nature, and disadvantage of larger deflection due to the lower modulus of elasticity than that of steel. Bridge deck is a preferred structure to apply FRP rebars due to the increase of flexural capacity by arching action. This paper focuses on the behavior of concrete bridge deck reinforced with newly developed GFRP rebars. A total of three real size bridge deck specimens were made and tested. Main variables are the type of reinforcing bar and reinforcement ratio. Static test was performed with the load of DB-24 level until failure. Test results were compared and analyzed with ultimate load, deflection behavior, crack pattern and width.

An Experimental Study on the Static Behavior in Weak Axis of FRP Bridge Deck Filled with a Foam (폼 충전 FRP 바닥판의 약축방향 정적거동 특성에 관한 실험적 연구)

  • Kim, Byeong Min;Zi, Goang Seup;Hwang, Yoon Koog;Lee, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6A
    • /
    • pp.943-953
    • /
    • 2006
  • We investigated experimentally the static behavior of an orthotropic bridge deck which is made from glass fiber reinforced polymer (GFRP) and polyurethane foam. The bridge deck consists of many unit cells with rectangular holes which are filled with the foam to improve its structural behavior in its weak axis. It is found that although the elastic modulus of the foam compared to that of the GFRP is about the order of, the structural behaviors in the weak axis such as nominal strength, stiffness, etc. are greatly improved. Owing to the low mass density of the foam used in this study, the bridge deck is still light enough with the improved structural properties. Webs of the cells filled with the foam did not significantly contribute to the strength development of the deck. However, the propagation of a crack initiated in a cell is caught by the webs and limited to the inside of that cell only, which makes the load-displacement behavior of the foam-filled GFRP deck less brittle.

Floor Impact Noise Characteristics Depending on the Experimental Conditions Using Impact Ball (실험조건에 따른 임팩트 볼의 바닥충격음 변화 고찰)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.92-99
    • /
    • 2011
  • In Japan, bang machine has been considered to have problems about not only the impact force and frequency response which are different from the real impact sources such as children's jumping and running, but also damage in the wooden structure housing. Therefore, a new impactor for lower impact force to prevent demage in wooden structure housing was developed. The impact ball was adopted as the second standard impact source in JIS A 1418-2 and ISO 140-11. In the present study, floor impact sounds generated by impact ball with drop heights in four floors of mock-up building of Building Research Institute (BRI) similar to typical Japanese wooden structure housing were investigated and also compared to jumping sound. The results show that Impact ball sound dropped at 10 cm to 30 cm was most similar to jumping sound. And The impact sound levels at 250 and 500 Hz were more sensitive to drop height than other lower frequencies. The error that may occur from the difference of height of 10 cm up and down based on the standard drop height caused by the impact ball operated by human hands was approx. 1 dB or less only in its value of characteristic, but it must be carefully taken into Impact ball in the Korea Standard.

Structural Performance Evaluation on Stress-Laminated Timber Bridge Deck Using Finite Element Analysis (유한요소해석을 이용한 응력적층 바닥판의 구조성능평가)

  • Shin, Yukyung;Eom, Chang-Deuk;Lee, Sang-Joon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • This paper represented the finite element analysis to estimate structural performance of stress-laminated deck, which is determined by deflection, stress, and aging characteristics of tensioning. After loading, the deflected shape showed plate behavior because pre-stressing make frictional force between each member. Compared between initial post-tension and the results, pre-stressing forces were decreased with deck deflection. This is because deflection occurred in the deck so that pre-stressing decreased due to load reduction. However, material plasticity was not considered so that advanced researches should be performed.

Behavior and Strength of Rib Stiffened SC Wall-slab Connection (리브 보강된 SC구조 벽-바닥 접합부의 거동 및 내력 평가)

  • Park, Joung Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.349-359
    • /
    • 2014
  • Until now, wall-slab plate of steel plate concrete has been constructed by joint. But, the shear plate has problems in the workability as well as structural integrity. This study investigates the behavior and strength of rib stiffened SC wall-slab connection. Seven prototype specimens of wall-slab connections were fabricated and tested. the structural safety of the specimens was confirmed through the monotonic loading test. Based on the experimental observations, this study propose the strength formula of the joint was proposed. To enhance the reliability of the proposed strength formula, analytical verification was performed through inelastic finite element analysis. Effect of parameters, such as, load point, friction coefficient, on the joint strength was examined. The proposed formula yields a conservative value for most cases.

Experimental Study on the Flexural Behavior of Inverted T-Shaped Steel·Concrete Composite Deck for Bridges (역T형강·콘크리트 합성바닥판의 휨거동에 관한 실험적 연구)

  • Kim, Sung Hoon;Park, Young Hoon;Lee, Seung Yong;Choi, Jun Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.331-340
    • /
    • 2008
  • This study is to suggest the details of new concept of bridge deck. Experimental studies on the behavior of a inverted T-shaped steelconcrete composite deck were carried out. The part of inverted T-shaped steel is embedded in concrete. Reinforced concrete deck specimen and composite deck specimens were fabricated and static bending fracture tests were conducted. The ultimate strength and fracture strength of specimens were evaluated. The effects of shear hole crossing bars of composite deck were also analyzed. From the results of experiments, composite deck with shear hole crossing bar increased shear strength, and showed typical tensile failure. Ultimate strength and fracture strength of composite deck with shear hole crossing bar are higher than those of reinforced concrete deck. The displacement of composite deck is higher than that of reinforced concrete deck.

Analysis of Effective Flexural Rigidity of Corrugated Steel-Concrete Composite Deck with I-beam Welded (I형강으로 보강된 강합성 절곡 바닥판의 유효 휨강성 분석)

  • Son, Chang-Du;Hong, Sung-Nam;Park, Jun-Myung;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.145-154
    • /
    • 2009
  • Steel-Concrete Composite Deck with I-beam welded is lighter and easier to construct than conventional in situ reinforced concrete slabs due to the I-beam embedded in the corrugated slab. For the calculation of effective flexural rigidity of conventional reinforced concrete structures, methods suggested in Design Standard for Roads and Bridges and ACI have been used. In this paper, the calculation methods were applied to steel-concrete composite deck with I-beam welded and then results of the steel-concrete composite deck were compared with those of reinforced concrete slabs. In addition, applicability of the methods to steel-concrete composite deck with I-beam welded was estimated. In order to compare the effective flexural rigidity, flexural experiments were conducted. Fifteen slabs were built and the variables considered in the experiments were studs, length of the slab, shape of the section and connecting methods.