• Title/Summary/Keyword: 바닥판 앵커

Search Result 7, Processing Time 0.021 seconds

Analytical and Experimental Studies on Partially Composite of Steel-Plate Girder Bridges Using Slab Anchors (바닥판 앵커를 사용한 플레이트거더교의 부분합성에 관한 해석 및 실험 연구)

  • Han, Sang Yun;Park, Nam Hoi;Yoon, Ki Young;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.325-332
    • /
    • 2004
  • Cross sections of steel-plate girder bridges are divided into three cross sections of non-composite, partially composite, and fully composite sections, according to their composite characteristics. The Korean provision for the partially and fully composite sections specifies general usage of the stud of shear connectors, whereas the one for the non-composite section specifies empirical usage of slab anchors. However, the actual behavior of the cross sections of steel-plate girder bridges using slab anchors is close not to the non-composite action, but to the partially composite action. Therefore analytical and experimental studies on partial composites of steel-plate girder bridges using slab anchors are performed in this study. Intial stiffness of the slab anchor is obtained by the experimental study for the first time, and the composite characteristic of simple-span and two-span continuous steel-plate girder bridges is investigated by the finite element analyses for the second time. Based on the obtained initial stiffness, the reduction effect of tensile stresses in the concrete-slab on the intermediate support of the continuous bridge is also considered herein.

Design Improvements for Crossbeams and Stringers of Steel Box Girder Bridge (강박스거더교 가로보와 세로보 합리화 연구)

  • Gil, Heungbae;Kang, Sang Gyu;Cho, Jun Sang
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This research carried out to optimize crossbeams and stringers of steel box girder bridges, which are parts of floor system and support loading from the bridge deck. In the current design practice, the crossbeam is densely deployed with a spacing of 6 meters, and the stringer is placed between the crossbeams. The crossbeams and stringer are connected to the deck through slab anchors but the allowable stress of the compression flange is determined by the lateral-torsional buckling. To increase economic efficiency of the steel box girder bridges. the increased spacing of the crossbeam was studied. The study shows that the spacing can be increased up to 10 meters. However, higher strength steel plates are necessary. Shear studs rather than slab anchors are also recommended to prevent lateral-torsional buckling strength of the crossbeams and stringer.

The Behavior of Composite Bridge Using Slab Anchor (Slab Anchor를 사용한 합성교의 거동특성 연구)

  • Han, Sang-Yun;Han, Taek-Hee;Kim, Jong-Hun;Kang, Young-Jong
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.177.1-182
    • /
    • 2002
  • 본 연구는 합성교량의 경우 브라켓이나 가로보에 사용되고 비합성교량의 경우 연결재로 사용되는 스랩앵커를 Push-Out Test를 하여 실험으로 얻은 특성을 실제 소수주형모델에 적용하여 FEM해석을 통하여 거동특성을 파악 하고자 한다. 일반적으로 전단연결재 실험의 경우 콘크리트 슬래브와 강재 주형 사이에 직접 길이 방향 전단력을 작용시킬 수 있을 뿐 아니라 실험의 편리함 때문에 주로 Push-out 실험이 많이 이용되고 있다. 본 실험에서는 BS-5400에 제시된 바에 근거하여 실험체를 제작하였다. 이 실험을 통하여 탄성구간에서의 강성(k) 값을 알아내어 3D FEM 해석에 적용한다. 이때 콘크리트 바닥판과 강재와의 연결을 축 방향으로는 특정한 강성 값을 넣을 수 있는 Joint Element를 사용하여 연결시키고, 1경간 단순지지와 2경간 연속교에 대하여 연구를 수행하는데, 1경간 단순지지의 경우에는 Joint Element에 여러 강성 값과 실험을 통해 얻은 강성 값을 적용하여 합성거동을 파악하고 강성 값에 따른 합성정도를 규명하고자 한다. 또한 2경간 연속교에서는 슬랩앵커의 강성 값을 적용하여 많이 문제시되고 있는 내부지점부에 슬랩앵커를 사용하였을 때 슬래브의 인장응력이 어떤 변화양상을 나타내는지 파악 하고자한다.

  • PDF

A Study on Piping Support Design Process in Plant Piping System (플랜트 배관계에서 배관지지대 설계 기법에 관한 연구)

  • Chung, Chulsup
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.6
    • /
    • pp.14-20
    • /
    • 2014
  • In this study, the stress analysis for the piping support design is performed as per the rules of the ASME Code, Section III, subsection NF-Component Support which provides a simplified method of design analysis for piping support. This method makes use of simple equations and conservative allowable stress limits for design and service loadings. For the base plate, code equation is satisfied within the allowable limits. Both anchor bolts and pipe strap are governed by the their interaction equations. The stresses resulting from various loadings and their combinations are within the allowable limits specified in the above mentioned ASME Code. Thus, it was proved that the structural integrity of the pump assembly was satisfactory.

Study on Effect of Anchor Bolt by Thermal Expansion of Sulfur Storage Tank under High Temperature (고온을 받는 유황저장탱크의 열팽창에 의한 앵커볼트 영향에 관한 연구)

  • Jung, Wook-Hwan;Kim, Jeong-Soo;Kim, Tae-Min;Kim, Moon-Kyum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.483-490
    • /
    • 2016
  • In plant industry, sulfur storage tank is made of steel and annular plate is connected with concrete foundation of ring wall type by anchor bolt. Due to keep sulfur at high temperature in tank by coil, sulfur storage tank is expanded larger than another tank stores fluid at room temperature. Generally, structural design of tank foundation is performed analysis with loading of temperature gradient between inner and outer surface, this method can't consider the phenomenon that load is intensively transferred to concrete foundation at anchor bolt. This means that temperature load is underestimated and causes crack of concrete near anchor bolt. In this study, evaluation formula considering temperature load transfer mechanism through anchor bolt is proposed and load acting on concrete foundation is rationally decided. For this purpose, it is analyzed variation of thermal load per various anchor bolt number using finite element model including tank annular plate and anchor bolt. Solution is proposed as specified term combining result of analysis and theoretical solution for evaluating load transferred by anchor bolt. For confirmation of validation of proposed formula, it is applied in design of sulfur storage tank at plant site, it shows that the formula can be practically applied.

A Study on Reinforcement Method of Concrete Block for Direct Fixation Tracks on Serviced Light Rail Transit (공용중인 경전철 직결 궤도 콘크리트 도상블록의 보강 방안 연구)

  • Jung-Youl Choi;You-Song Kang;Dae-Hee Ahn;Jae-Min Han;Jee-Seung Chung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.633-640
    • /
    • 2023
  • In this study, numerical analysis was performed based on field investigation to derive an appropriate reinforcement method by analyzing the displacement behavior characteristics of concrete blocks generated in the direct fixation track on the bridges of the serviced light rail transit. The track of this study was a direct fixation track on a sharp curved track, and the problem of movement of the concrete blocks installed on the bridge deck in the longitudinal and lateral directions occurred. In this study, based on the finite element model using 3D solid elements, the behavior of the direct fixation track that could be occurred under operating load conditions was analyzed. In addition, the reinforcement effect of various reinforcement methods was analyzed. As a result of analyzing the lateral displacement before and after reinforcement, it was analyzed that the maximum lateral displacement after reinforcement under the extreme lateral wheel loads significantly decreased to about 3% (about 0.1mm) compared to before reinforcement. In addition, as a result of examining the generated stress of the filling mortar, bridge decks, and reinforcing bar, it was analyzed that all of them secured a sufficient safety factor of 2.6 or higher, and the optimal conditions for the reinforcement method were derived. Therefore, it is judged that the number of anchoring reinforcements and symmetrical anchor placement reviewed in this study will be effective in controlling the occurrence of lateral displacement of concrete blocks and securing the structural integrity of bridges and concrete blocks.

Three-dimensional finite element static analysis and safety evaluation of attachable roadside barriers on bridges (탈·부착식 교량 방호울타리의 3차원 유한요소 정적해석 및 안전성 평가)

  • Lee, Sang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2414-2418
    • /
    • 2014
  • This study carried out three-dimensional finite element analysis and structural safety evaluation of attachable roadside barriers. The effects of diaphragm distance and the number of bolts on displacements and maximum stresses for various parameters are studied using the LS-DYNA finite element program for this study. In this study, the existing finite element analysis of barriers using the LS-DYNA program is further extended to study static behaviors and structural safety of the barrier with module structures connected by anchor bolt inserted through concrete bridge decks. The numerical results for six parameters are verified by comparing different models with displacements and stress distribution occurred in the barrier and shows good structural performance.