An Experimental Study on the Prediction Method of Light Weight Floor Impact Sound Insulation Performance of Apartment Floor Structures through Mini-Laboratory Tests (축소실험실을 이용한 바닥완충구조의 경량충격음 차음성능 예측방법에 관한 실험적 연구)

  • 송민정;장길수;김선우
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.82-96
    • /
    • 2000
  • The purpose of this study is to figure out the relationship between the mini-laboratory and the reverberation room for the domestic floor structures which are practically constructed in apartment houses. For this purpose, seven specimen which were varied in structures and thicknesses were tested in Chonnam National University reverberation room and in the artificial mini-laboratory which is the $\farc{1}{3}$ scale model of the former. From the result of this study, it was proved that there is a good correlation between the mini-laboratory and the reverberation room for the apartment floor structures as well as floorcovering PVC. The result of this study could save the labor and the time, etc.

  • PDF

Investigation of the level difference of floor impact noises through the shape variation of EVA resilient materials with composite floor structure (EVA 완충재의 형상변환을 통한 복합구조의 바닥충격음 변이 조사)

  • Jakin Lee;Seung-Min Lee;Chan-Hoon Haan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.60-71
    • /
    • 2024
  • The present study aims to investigate the level difference of floor impact noises of composite floor structure using EVA resilient materials. In order to this, four different types of resilient materials were designed combining PET, PP sheet and EVA mount including Flat type, Deck type, Cavity type and Mount type. Totally 9 different samples were made for acoustic measurements which were carried out twice with bang-machine and impact ball as the heavy-weight floor impact noise sources. All the floor impact noise measurements were undertaken at the authentication institution. As a result, concerning Flat and Cavity types, it was found that 2 dB ~ 5 dB of heavy-weight floor impact noise was reduced supplementally when PET was added, while floor impact noise larger than 50 dB was acquired when single resilient material was used. Especially, most high performance was obtained for Mount type with 1st grade of light-weight floor impact noise and 2nd grade of heavy-weight floor impact noise. This is because of material property with low dense PET sound absorption materials which fill all around EVA mounts. Also, it was considered that this results are due to the sound impact absorption by the both EVA mounts and the air cavity between EVA mount and PP sheet. Also, it was found that at least 36 EVA mounts per 1m2 area of resilient panel make more noise reduction of heavy-weight floor impact noises.

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources (중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구)

  • Yoo, Seung-Yup;Yeon, Jun-Oh;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.

Dynamic Characteristic of Post-tensioned Void Slab (포스트텐션 중공슬래브의 동적 특성)

  • Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.89-95
    • /
    • 2012
  • Post-tensioned void slab is frequently used for improving the deflection and sound proofing. Two one story 8m spanned structures were built. One structure applied post-tensioned solid slab, but the other did post-tensioned void slab. Dynamic characteristics, which is natural frequency and damping ratio, was compared between that of solid slab and void slab before and after post tension. The natural frequency of void slab was greater than that of solid slab before and after post tension. It was shown that damping ratio of solid slab and void slab was almost same at two stages.

A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment (벽식구조 공동주택의 바닥충격음 개선에 대한 연구)

  • Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

A Survey on Foreign and Domestic Interior Noise Criteria for Walls and Floors (공동주택 내부소음 기준과 바닥 및 벽체 차음성능 기준 고찰)

  • Kim, Sun-Woo;Song, Min-Jeong
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.37-44
    • /
    • 2004
  • In this study, foreign and domestic noise criteria on walls, floors, and water supply facilities were reviewed and the results are as follows : regulation can be divided two things, one is on thickness the other is sound insulation performance. Green Building regulation based on the law and this have sound classification systems. Since these regulations are not established in Korea. The noise regulation on water supply-drain facilities and domestic guideline on interior noise level is needed. Foreign regulations are stricter than those of ours. And those has sound classification system for the better acoustic condition of inhabitants'.

The Evaluation of Floor Impact Sound Insulation in Apartment House by Psycho-acoustic Method (현장(現場) 청감실험(聽感實驗)에 의한 바닥충격음(衝擊音) 차음성능(遮音性能) 평가(評價))

  • Gi, No-Gab;Jang, Gil-Soo;Song, Min-Jeong;Kim, Jun-Yup;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1741-1746
    • /
    • 2000
  • Recently the impact sound insulation performance is regarded as one of the most important factor in determining the quality of apartment house. So many studies were carried out to improve these performance and to propose an appropriate evaluation method and standard of floor impact sound insulation for apartment house by psycho-acoustic method in the laboratory. This study was carried out the field psycho-acoustic test to find a correlation between physically measured values and psychological response in apartment house, and the results will be used to establish the appropriate evaluation method and standard of floor impact sound insulation.

  • PDF

A Study on the Insulation Performance of Impact Sound Level by Striking Location of Floor Slab (바닥 슬라브의 가진 위치에 따른 차음성능에 관한 연구)

  • Song, Pil-Dong;Park, Myung-Kil;Ham, Jin-Sik
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.73-76
    • /
    • 2003
  • This paper is contents about method to measure interception performance of shock noise of floor slab of apartment house to be simple. In the case of interception performance of light floor impact sound level, according to measurement method, grade of sound insulation performance showed greatly differently. But, in the case of interception performance of heavy floor impact sound level, it was similar result in all measurement method. Therefore, use of simple method of measurement was examined by possible fact in case of interception performance of heavy floor impact sound level.

  • PDF