• Title/Summary/Keyword: 민감도 측정

Search Result 1,700, Processing Time 0.048 seconds

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF

The Usefulness in an Automated Kinetic Method in Determining of ADA Activity in Pleural Fluid (자동화학분석기를 이용한 흉막액내 ADA 활성치 측정의 유용성에 관한 연구)

  • Ryu, Jeong-Seon;Yong, Suk-Joong;Song, Kwang-Seon;Shin, Kye-Chul;Lee, Won-Sik;Kang, Shin-Ku;Uh, Young;Yoon, Kap-Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.838-845
    • /
    • 1995
  • The determination of ADA(adenosine deaminase) activity in pleural fluid is useful in differental diagnosis of pleural effusion. The conventional method of determining ADA activity used by Giusti was influenced by contamination of ammonia. Additionally, because Giusti's method was mannual method a determining the ADA activities in sample, was not easily automated. In 1993, Oosthuizen HM with collegues developed simple kinetic method for determining ADA activity. It was reliable and suiable method for automation. In this study, we have measured ADA activity in 162 patients with various pleural effusion by Hitachi 747 autoanalyser using the Oosthuizen kinetic method for the purpuse of determination of new diagnostic cut-off value for the tuberculous effusion and evaluation of the correlation between the conventional method and new automated method. This new method of an enzymatic reaction involves 2, 6-dichlorophenolindophenol dye(DICP), adenosine, xanthine oxidase(XO), and nucleoside phosphorylase(NP). The results were as follows: 1) The mean pleural ADA activity of the tuberculous effusion was $52.53{\pm}16.43\;U/L$ and significantly higher than that of other groups(p<0.001). If the diagnostic cut-off value of pleural ADA activity for tuberculous effusion is above 30 U/L, the sensitivity is 96% and the specificity is 90%. 2) The mean pleural to serum ADA activity ratio of the tuberculous effusion was $2.29{\pm}0.96$ and it was also significantly higher than that of other pleural groups(p<0.001). If the diagnostic cut-off value of pleural to serum ADA activity ratio is 1.5, the sensitivity is 80% and the specificity is 88% in the diagnosis of tuberculous pleural effusion. 3) The new kinetic method is correlates well to Giuisti's conventional method(r=0.971). In conclusion, the new kinetic method described is easily automated and seems to be suitable for the routine determination of ADA activity.

  • PDF

The Assessment of Ultrasensitive HBsAg kit's Sensitivity level and Performance in Detection of Mutant Forms (Ultra-sensitive HBsAg IRMA 키트의 민감도 및 변이형 검출능 평가)

  • Ha, Dong-Hyuk;Min, Kyung-Sun;Noh, Gyeong-Woon;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.121-125
    • /
    • 2011
  • Purpose: The DNA-type virus HBV, discovered by D. Dane and others in 1976, is approximately 42nm big and known as the main cause of liver-related diseases around the world. HBsAg has 4 kinds of subtypes including adw, adr, ayw and ayr and besides common antigen factor a, there are d, y, r, w. From the methods of serologically testing HBV, IRMA, EIA and CLIa were developed for testing HBsAg and are being used in examining the surface antigen of HBV. In this study, among the methods for testing HBV, the recently developed RIAKEY Ultrasensitive HBsAg IRMA kit's sensitivity level and performance in detection of mutant forms were measured and compared with CLIA. Materials and methods: Two certified reference materials, which are WHO 1st International Standard 1985(80/549) and WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA), were used in the examination and the sensitivity level was measured by diluting these materials from 0.08 IU/ml to 0.005 IU/ml. The materials for examining the detection of mutant forms included 9 kinds of subtype 'ad' and one kind of subtype 'ay' purchased from DSI company. Also, with the use of positive and negative samples, they was compared with CLIA. Result: Ultrasensitive HBsAg kit based on IRMA method showed the detection of up to 0.01 IU/ml not only for WHO 1st International Standard 1985(80/549) but also for WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA) and the sensitivity level was measured as 0.01 IU/ml by WHO standard. In testing the performance for detection of mutant forms, the 9 kinds of subtype 'ad' and one kind of subtype 'ay' mutant materials were detected, demonstrating the capacity of detecting various types of mutant forms. Conclusions: With the clinical importance of sensitivity level and performance in detection of mutant forms increasing in the field of HBsAg diagnosis, the examination of IRMA's effectiveness using RIA method in the aspects of the sensitivity level and performance in detection of mutant forms was carried out and its result is as follows. The sensitivity level was measured as 0.01 IU/ml by WHO standard and it was possible to measure various types of mutant forms with high sensitivity. Thus it is suggested that more speedy and accurate reports could be produced from a nuclear medicine laboratory for clinical practitioners requiring results of various situations.

  • PDF

A Study on the Grain Moisture Measurement using Microwave Attenuations at Two frequencies (두 개의 주파수에서 마이크로파 감쇄를 이용한 곡물의 함수율 측정에 관한 연구)

  • 김송흡;조경준;김종헌
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.268-271
    • /
    • 2000
  • 본 논문에서는 X-band의 10.5 GHz와 S-band의 2.38 GHz 두가지 주파수를 이용하여 곡물의 함수율 측정을 위한 마이크로파 송수신 장치를 설계 및 제작하였다. 측정 장치들의 핵심부품인 발진기, 송수신 패치안테나와 검파기는 HP EEsof ADS를 이용하여 설계하였으며 하이브리드 MIC형태로 제작하였다. 이 송수신 측정장치를 이용하여 측정된 데이터를 통계분석 프로그램으로 회귀 분석하여 밀도에 민감하지 않은 새로운 보정 모델을 제시하였다. 시료의 출력 전압을 독립변수로 한 함수율 측정 모델을 가지고 함수율의 예측값과 실측값을 비교한 결과 상관계수는 0.9276, 표준오차는 0.975 %로 나타나 산물밀도를 보정하면서 정확도가 높은 벼의 함수율 측정이 가능하였다.

  • PDF

Measuring Allowable Vibration of Vibration-Sensitive Equipment (정밀 장비의 진동 허용치 측정 방법)

  • Yeo, Myeong Hwan;Park, Hae Dong;Jung, Jin Ho;Kim, Kang Boo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.162-166
    • /
    • 2014
  • 정밀 장비의 진동 허용치는 장비의 성능을 저하시키지 않는 외부 진동의 허용 범위를 의미하는 것으로 BBN 기준, NIST 기준 등이 있다. 반도체 및 디스플레이 산업 현장에서 주로 적용되는 BBN 기준을 평가하기 위해 측정시 측정자에 따라 상이한 결과가 발생하기도 한다. 이는 계측기의 설정 및 분석 방법 등 측정 방법의 차이에서 기인하는 것으로 관련된 측정 방법에 대한 가이드가 없기 때문인 것으로 보인다. 본 논문에서는 BBN 기준 평가를 위해 정밀 장비의 진동 허용치를 측정시 분석 방법, 평균화 방법 및 등급 판정 방법에 대한 가이드를 제안한다.

  • PDF

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

Validity of Peak Expiratory Flow for Assessing Reversible Airflow Obstruction (기류 가역성 평가에 있어서 최대호기유속 측정의 유용성)

  • Chol, Won-Il;Kwak, Jin-Ho;Kwon, Doo-Young;Han, Seung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.522-529
    • /
    • 2000
  • Backgrounds : Assessment of the presence and degree of reversibility of airflow obstruction is clinically important in patients with asthma or chronic obstructive pulmonary disease. The measurement of peak expiratory flow(PEF) is a simple, fast, and cheap method to assess the severity of obstruction and its degree of reversibility. Assessing the reversibility of airflow obstruction by peak expiratory flow(PEF) measurements is practicable in general practice, but its usefulness has not been well investigated. We compared PEF and $FEV_1$ in assessing reversibility of airflow obstruction in patients with chronic obstructive pulmonary disease or asthma and developed a practical criterion for assessing the presence of reversibility in general practice. Methods : PEF measurements were performed (Spirometry) in 80 patients(aged 24-78) with a history of asthma or chronic obstructive lung disease before and after the inhalation of 200 g salbutamol. The change in PEF was compared with the change in forced expiratory volume in one second($FEV_1$). Reversible airflow obstruction was analyzed according to American Thoracic Society(ATS) criteria. Results : A 12% increase above the prebronchodilator value and a 200ml increase in either FVC or $FEV_1$ reversibility were observed in 45%(36) of the patients. Relative operating characteristic(ROC) analysis showed that an absolute improvement in PEF of 30 l/min gave optimal discrimination between patients with reversible and irreversible airflow obstruction(the sensitivity and specificity of an increase of 30 l/min in detecting a 12% increase above the prebronchodilator value and a 200ml increase in either FVC or $FEV_1$ were 72.2% and 72.7% respectively, with a positive predictive value of 68.4%). Conclusions : Absolute changes in PEF can be used to diagnose reversible airflow obstruction.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Usefulness of Corticomedullary-Phase CT Urography in Patients with Suspected Acute Renal Colic Visiting the Emergency Department (응급실을 방문하는 급성신산통이 의심되는 환자에서 요로조영술 컴퓨터단층촬영의 피질-수질기의 유용성)

  • Seokyoung Lee;Yang Shin Park;Bitna Park;Jongmee Lee;Jae Woong Choi;Kyeong Ah Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.923-933
    • /
    • 2023
  • Purpose To evaluate the sensitivity of corticomedullary-phase imaging for detecting urinary stones in patients with renal colic who visited the emergency department. Materials and Methods This retrospective study included 253 patients with suspected renal colic from two tertiary hospitals in South Korea, who visited the emergency department and underwent CT urography. Two radiologists blinded to the clinical history independently reviewed the corticomedullary-phase images. The sensitivity for identifying urinary stones were evaluated for each reviewer. After the initial evaluation, the images were re-evaluated based on patient history. The sensitivity of re-evaluation were recorded. Results Of 253 patients, 150 (59%) had urinary stones. Among them, significant stones were observed in 138 patients (92%), and obstructive changes on CT in 124 patients (82.7%). For identifying significant urinary stones, the sensitivity was 98.6% (136/138) for both the reviewers. For identifying significant urinary stones with urinary obstruction, the sensitivity was 99.2% (123/124) for reviewer 1, and 100% (124/124) for reviewer 2. The sensitivity for identifying significant stones increased from 98.6% to 100% for reviewer 1, and from 98.6% to 99.3% for reviewer 2 in the re-evaluation session. Conclusion The corticomedullary-phase CT urography was sensitive for diagnosing urolithiasis in patients with acute renal colic who visited the emergency department.

An Objective Image Quality Measurement Considering Skipped & Estimated Positions of Pixels in Image Scaling (영상 크기 변환에서 화소들의 생략 및 추정 위치를 고려한 객관적 영상 화질 측정)

  • Kim, Won-Hee;Moon, Kwang-Seok;Kim, Jong-Nam
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.8
    • /
    • pp.934-942
    • /
    • 2013
  • Image scaling is used for a variety of real-life applications. In order to evaluate the performance of transform functions, the image quality are compared together before and after processing. For the objective evaluation of the transform functions, the exact criterion of image quality is required, and various aspects approaches are practically performed. However, few researches have been conducted on image quality measurement considering the position of pixels that are skipped or newly generated in the process of the image scaling. Therefore this paper focuses on the objective image quality measurement for positions of skipped or estimated pixels in the image scaling. The proposed method generated new image quality measure considering the positional changes using a conventional measure and evaluated sensitivity about positional changes. Through this experiments, it is observed that conventional image quality measurement is definitely affected by positional changes of a skipped and estimated pixels. It is also confirmed that the proposed method is an objective criterion to represent image quality for positional changes of skipped or estimated pixels. The proposed method can be used as a criterion to evaluate the performance of image restoration or enhancement functions.