• Title/Summary/Keyword: 민감도와 특이도

Search Result 526, Processing Time 0.036 seconds

The Diagnostic Utility of PET-CT for the Preoperative Evaluation of Lymph Node Metastasis in Gastric Cancer Patients (위암 환자의 수술 전 림프절 전이 평가를 위한 PET-CT의 진단적 유용성)

  • Park, Sung-Hyuk;Cho, Min-Su;Ryu, Hoon;Bae, Keum-Seok;Kim, Ik-Yong;Kim, Dae-Sung
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.250-255
    • /
    • 2008
  • Purpose: The purpose of this study was to assess the diagnostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for detecting the lymph node (LN) metastasis of gastric cancer. Materials and Methods: 119 patients (M : F=89 : 30; mean age: 64) with gastric cancer were referred for preoperative FDG-PET/CT scanning and spiral enhanced abdominal pelvic CT from June 2006 to July 2008, and these were the subjects of our study. All the patients underwent curative radical gastrectomy and lymph node dissection. A final diagnosis was made for all the patients by the histology of the surgical specimens. Results: Both PET/CT and enhanced CT showed similar sensitivity for detecting regional lymph node metastasis (32.6% vs 39.5%, respectively). PET/CT was more accurate than enhanced CT for detecting regional lymph node metastasis (67.2% vs 63.0%, respectively), and PET/CT showed better specificity (86.8% vs 76.3, respectively) and a better positive predictive value (PPV) (58.3% vs 48.6%, respectively). PET/CT showed better specificity (98.0% vs 88.2%, respectively) and accuracy (79.4% vs 73.9%, respectively) than enhanced CT for detecting early gastric cancer. PET/CT showed better specificity (64.0% vs 52.0%, respectively), a better PPV (60.9% vs 57.1%), a better negative predictive value (NPV) (48.5% vs 46.4%, respectively) and better accuracy (53.6% vs 51.8%, respectively) than enhanced CT for detecting advanced gastric cancer. Conclusion: FDG-PET/CT is more usefulness than enhanced CT for making the preoperative diagnosis of regional LN metastases from gastric cancers.

  • PDF

Comparison Study of Lesion Localization in Patients with Primary and Secondary Hyperparathyroidism using Double-Phase Tc-99m Sestamibi Scintigraphy (일차성 및 이차성 부갑상선기능항진증 환자에서 Double-Phase Tc-99m Sestamibi 스캔에 의한 병변의 국소화에 관한 비교)

  • Jeon, Tae-Joo;Lee, Jong-Doo;Rhyu, Young-Hoon;Park, Jung-Soo;Jang, Hang-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.368-380
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate and compare the scintigraphic findings and diagnostic accuracy of double-phase Tc-99m sestamibi scan in primary and secondary hyperparathyroidism (HPT). Materials and Methods: We retrospectively reviewed 16 cases of primary (18 lesions) and 11 cases of secondary HPT (44 lesions) who underwent Tc-99m-sestamibi scan before the surgical intervention. Scan was performed using LEM camera (Siemens, Germany) after the injection of 740MBq of Tc-99m sestamibi. Routine image consisted of baseline and 3-hour delayed images and each image was obtained using both parallel and pine hole collimator. The study population was 27 patients (male/female=5/22, age: $49.1{\pm}10.8$). Results: Eighteen lesions of primary HPT consisted of 13 adenomas and S hyperplasias, while all lesions of secondary HPT were hyperplasias. Among the case of primary HPT, we could detect all the lesions of 13 adenomas but only 2 lesions of 5 hyperplasias (40%) could be detected by double phase scintigraphy. Three cases of primary lesion showed decreased uptake in delayed images compared with baseline. The sensitivity, specificity, positive predictive value and accuracy of primary and secondary HPT were 58.8% (10/17), 83.3% (10/12), 83.3% (10/12), 75.9% (22/29), and 37.5% (15/40), 50% (2/4), 88.2% (15/17), 38.6% (17/44), respectively. Overall sensitivity, specificity, positive predictive value and accuracy were 43.9% (25/57), 75% (12/16), 86.2% (25/29), and 53.4% (39/73). There were no statistical difference between the weight of primary and secondary HPT lesion (p>0.05). Conclusion: Tc-99m sestamibi scan is fairly good modality to detect parathyroid lesion in patient with primary HPT before the surgical intervention. However, since some of cases may reveal decreased uptake in delayed image, a careful attention to the findings of baseline images may be helpful. Still the low accuracy of sestamibi scan in diagnosis of secondary HPT prohibits routine use of it for this disease.

  • PDF

Comparison of Tc-99m DISIDA Hepatobiliary Scintigraphy and Percutaneous Needle Biopsy in the Differential Diagnosis of Biliary Atresia and Intrahepatic Cholestasis (영아 담도폐쇄증 진단에서 Tc-99m DISIDA 간담도주사와 경피간침생검의 의의)

  • Kim, Woo-Suk;Park, Woo-Hyun;Choi, Soon-Ok;Kim, Sang-Pyo
    • Advances in pediatric surgery
    • /
    • v.3 no.1
    • /
    • pp.6-14
    • /
    • 1997
  • To differentiate biliary atresia from intraheaptic cholestasis, Tc-99m DlSIDA hepatobiliary scintigraphies and percutaneous needle biopsies of 60 consecutive infants were evaluated retrospectively. Twenty three patients had biliary atresia and 37 patients intraheaptic cholestasis(neonatal hepatitis 34, TPN induced jaundice 2 and Dubin-Johnson syndrome 1). All sixty patients underwent Tc-99m DlSIDA hepatobiliary scintigraphy with phenobarbital pretreatment. Of 23 patients with biliary atresia, 22 were correctly interpreted showing 96% sensitivity while of 37 patients with intraheaptic cholestasis, only 12 had intestinal excretion of radionuclide showing 32% specificity. Among the forty needle biopsies, 17 of biliary atresia and 23 of intrahepatic cholestasis, 37 were correctly interpreted as either having biliary atresia or intrahepatic cholestasis. The overall diagnostic accuracy was 93%. Of 3 misdiagnosed cases, the histologic findings of two patients with biliary atresia(aged 43 days and 54 days at the first needle biopsy) were essentially the same as those of neonatal hepatitis. Follow-up biopsies, however, showed findings consistent with biliary atresia. The third one(VLBW premie with history of 8 weeks of TPN) showed mild ductal proliferation and portal fibrosis. This was interpreted as suspicious for biliary atresia. Jaundice resolved gradually. In summary, patients who have intestinal excretion of radionuclide on Tc-99m DlSIDA hepatobiliary scintigraphy, biliary atresia can be ruled out. But the patients who do not have intestinal excretion of radionuclide should have further investigation by needle biopsy. Judicious use of Tc-99m DISIDA hepatobiliary scintigraphy and percutaneous needle biopsy can give a diagnostic accuracy of 95% or more in cases of infantile cholestasis.

  • PDF

Detection of Pathogenic Yersinia Enterocolitica in Drinking Water and Vegetables by Mutiplex-PCR (Multiplex-PCR에 의한 먹는샘물 및 야채류로부터의 병원성 Yersinia enterocolitica의 신속검출)

  • 이택수;박부길;오덕환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.35-41
    • /
    • 2003
  • The study was conducted to develope a rapid method for the detection of Yersinia enterocolitica in spring water and vegetables via multiplex polymerase chain reaction (PCR) technique using ail, yst, uirF and subgenus-specific Y16S primers. Specificity and sensitivity of multiplex PCR and application of best primers for the detection of Y. enterocolitica from spring water and vegetables were investigeted. Y. enterocolitica ATCC 27729 strains gave 356 bP and 200 bp (Y16S) and 134 bp (yst) bands. but Y. enterocolitica ATCC 9610 and ATCC 23715 strains gave 200 bp and 134 bp bands.In the meanwhile, non-pathogenic Yersinia species, such as Y. frederikseni, Y. inter-media, Y. kristenseni and Y. pseudotuberculosis gave only single 200 bp band, and other bacteria including Escherichia coli O157:H7 ATCC 25392, Shigella dysenteri. Staphylococcu aureus ATCC 25923 and Listeria mo-nocytogenes ATCC 19111 did not show any bands. Among primers, yst and Y16S primer showed the best sensitivity. Seven CFU/mL Y. enterocolitica cells could be detected with yst and Y16S primers and the sensitivity was significantly improved by the further 2nd PCR after 38 cycles of first PCR amplication. Spring water, cabbage and mushroom were inoculated with Y. enterocolitica to determine the sensitivity of multiplex-PCR for the rapid detection of Y. enterocolitica. Multiplex-PCR assay could detect 7 or 70 cells in spring water and vegetables using whole cell lysate with repeating PCR amplication.

Cost-Sensitive Learning for Cardio-Cerebrovascular Disease Risk Prediction (심혈관질환 위험 예측을 위한 비용민감 학습 모델)

  • Yu Na Lee;Kyung-Hee Lee;Wan-Sup Cho
    • The Journal of Bigdata
    • /
    • v.6 no.2
    • /
    • pp.161-168
    • /
    • 2021
  • In this study, we propose a cardiovascular disease prediction model using machine learning. First, a multidimensional analysis of various differences between the two groups is performed and the results are visualized. In particular, we propose a predictive model using cost-sensitive learning that can improve the sensitivity for cases where there is a high class imbalance between the normal and patient groups, such as diseases. In this study, a predictive model is developed using CART and XGBoost, which are representative machine learning technologies, and prediction and performance are compared for cardiovascular disease patient data. According to the study results, CART showed higher accuracy and specificity than XGBoost, and the accuracy was about 70% to 74%.

Diagnostic Usefulness of Serum Level of Cyfra 21-1, SCC Antigen and CEA in Lung Cancer (폐암에서 혈중 Cyfra 21-1, SCC 항원 및 CEA의 진단적 유용성)

  • Kim, Kyoung-Ah;Lee, Me-Hwa;Koh, Youn-Suck;Kim, Seon-Hee;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Moon, Dae-Hyuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.846-854
    • /
    • 1995
  • Background: Cytokeratin 19 is a subunit of cytokeratin intermediate filament expressed in simple epithelia such as respiratory epithelial cells and their malignant counterparts. An immunoradiometric assay is available to detect a fragment of the cytokeratin, referred to as Cyfra 21-1 in the serum. This study was conducted to evaluate the clinical utility of this new marker in the diagnosis of lung cancer compared with established markers of squamous cell carcinoma antigen (SCC Ag) and carcino-embryonic antigen(CEA). In addition, we compared the diagnostic sensitivity and specificity of Cyfra 21-1 with those of SCC Ag in squamous cell carcinoma of the lung. We also measured the level of Cyfra 21-1 in the different stages of squamous cell carcinoma of the lung. Method: We measured Cyfra 21-1(ELSA-CYFRA 21-1), SCC Ag(ABBOTT SCC RIABEAD) and CEA(ELSA2-CEA) in 79 patients with primary lung cancer and in 78 persons as a comparison group including 32 patients with pulmonary tuberculosis, 23 patients with benign lung disease and 23 cases with healthy individual. Cyfra 21-1 is measured by a solid-phase immunoradiometric assay(CIS Bio International, France) based on the two-site sandwich method. SCC Ag is measured by a radioimmunoassay(Abbott Laboratories, USA). CEA is measured by a immunoradiometric assay(CIS Bio International, France). All data were expressed as the mean$\pm$standard deviation. Results: 1) The mean value of Cyfra 21-1 was $18.38{\pm}3.65\;ng/mL$ in the lung cancer and $1.l6{\pm}0.53\;ng/mL$ in the comparison group(p<0.0001). SCC Ag was $3.53{\pm}6.06\;ng/mL$ in the lung cancer and $1.19{\pm}0.5\;ng/mL$ in the comparison group(p<0.01). CEA was $35.03{\pm}13.9\;ng/mL$ in the lung cancer and $2.89{\pm}1.01\;ng/mL$ in the comparison group(p<0.0001). 2) Cyfra 21-1 level in squamous cell carcinoma($31.52{\pm}40.13\;ng/mL$) was higher than that in adenocarcinoma($2.41{\pm}1.34\;ng/mL$)(p<0.0001) and small cell carcinoma($2.15{\pm}2.05\;ng/mL$)(p=0.007). SCC Ag level in squamous cell carcinoma($5.1{\pm}7.68\;ng/mL$) was higher than that in adenocarcinoma($1.36{\pm}0.69\;ng/mL$)(p=0.009) and small cell carcinoma($1.1{\pm}0.24\;ng/mL$) (p=0.024). 3) The level of Cyfra 21-1 was not correlated with the progression of stage in squamous cell carcinoma of the lung. 4) Using the cut-off value of 3.3ng/mL, the diagnostic sensitivity of Cyfra 21-1 was 83% in squamous cell carcinoma, 22% in adenocarcinoma and 17% in small cell carcinoma. The sensitivity of SCC Ag and CEA were 39% and 20%, respectively in squamous cell carcinoma, 11% and 39% in adenocarcinoma, and 0% and 33% in small cell carcinoma. 5) Comparison of the receiver operating characteristics curves(ROC curve) for Cyfra 21-1, SCC Ag and CEA revealed that Cyfra 21-1 showed highest diagnostic sensitivity among them in the diagnosis of lung cancer. Conclusion: Cyfra 21-1 is thought to be a better tumor marker for the diagnosis of lung cancer than SCC Ag and CEA, especially in squamous cell carcinoma of the lung.

  • PDF

Development of Multiplex PCR Assay for Identification of Eight Species from Meats in Korea (국내에서 유통되는 8종의 식육감별을 위한 multiplex PCR법 개발)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Yoon, Hyang-Jin;Kim, Yeon-Hwa;Kim, Young-Jo;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • Species identification of animal tissues in meat products is an important issue to protect the consumer from illegal and/or undesirable adulteration; for economic, religious and health reasons. In this reason, accurate analytical methods are needed for the labeling of meat products with requiring simple and fast procedure. Recently, applications of PCR in food analysis have been increased because of their simplicity, specificity and sensitivity. Therefore, in this study, a multiplex PCR assay was developed for the simultaneous identification of eight species of cow, pig, chicken, duck, goat, sheep, horse and turkey from raw meats. The primers were designed in different regions of mitochondrial 16S RNA after alignment of the available sequences in the GenBank database. Two multiplex primer sets were designed as Set 1 (cow, pig, chicken, duck) and Set 2 (goat, sheep, horse, turkey), respectively. Total 274 samples from cow (n = 55), pig (n = 30), chicken (n=30), and duck (n = 30), goat (n = 40), sheep (n = 33), horse (n = 41), and turkey (n = 15) were tested. The primers generated specific fragments of 94, 192, 279, 477 bp (pig, chicken, cow, duck), 670, 271, 152, 469 bp (goat, sheep, horse, turkey) lengths for eight species, respectively. The animal species specificity was 100% in all eight samples in the multiplex PCR assay. The detection limit of the multiplex PCR assay showed from 100 fg to 1 pg of template DNA from extracted from raw meats. When applying multiplex PCR assays to sample from pork/beef and pork/chicken, beef/chicken tested raw mixed meats and heat-treated ($83^{\circ}C$ for 30min, $100^{\circ}C$ for 20min, and $121^{\circ}C$ for 10min) mixtures, detection limit was 0.1% level beef, pork and pork in beef and chicken in pork and 1.0% level pork in chicken. This study suggest that the developed multiplex PCR assay can be used for rapid and simultaneous species identification of cow, pig, chicken, duck, goat, sheep, horse and turkey from meats.

Study on the Usefulness about Molecular Breast Imaging In Dense Breast (치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰)

  • Baek, Song Ee;Kang, Chun Goo;Lee, Han Wool;Park, Min Soo;Choi, Young Sook;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

  • PDF

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF

Role of FDG-PET in the Diagnosis of Recurrence and Assessment of Therapeutic Response in Cervical Cancer and Ovarian Cancer Patients: Comparison of Diagnostic Report between PET, Abdominal a and Tumor Marker (자궁경부암 및 난소암 환자 재발진단과 치료반응평가에 있어서 FDG-PET의 역할: 양전자방출단층촬영, 복부전산화단층촬영 및 종양표지자 판독의 비교 분석)

  • Han, You-Mie;Choe, Jae-Gol;Kang, Bung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.201-208
    • /
    • 2008
  • Purpose: We aimed to assess the role of positron emission tomography using fluorodeoxyglucose (FDG-PET) in the diagnosis of recurrence or the assessment of therapeutic response in cervical and ovarian cancer patients through making a comparison between FDG-PET, abdominal computed tomography (CT) and serum tumor marker. Materials and methods: We included 103 cases (67 patients) performed FDG-PET and abdominal CT. There were 42 cervical cancers and 61 ovarian cancers. We retrospectively reviewed the interpretations of PET and CT images as well as the level of tumor marker. We calculated their sensitivity, specificity, positive predictive value and negative predictive value for these three modalities. And then we analyzed the differences between these three modalities. Results: Tumor recurrences were diagnosed in 37 cases (11 cervical cancers and 26 ovarian cancers). For PET, CT and tumor marker, in cervical cancer group, sensitivity was 100% (11/11), 54.5% (6/11) and 81.1% (9/11), respectively. And specificity was 93.6% (29/31), 93.6% (29/31) and 100% (31/31). In ovarian cancer group, sensitivity was 96.2% (25/26), 84.6% (22/26) and 80.8% (21/26), and specificity was 94.3% (33/35), 94.3% (33/35), 94.3% (33/35), PET was highly sensitive to detect the intraperitoneal and extraperitoneal metastasis with the help of the CT images to localize the lesions. However, CT had limitations in differentiation of the recurrent tumor from benign fibrotic tissue, identification of viable tumors at the interface of tissues, and detecting extraperitoneal lesions. Conclusion: FDG-PET can be an essential modality to detect the recurrent or residual tumors in gynecologic cancer patients because of its great field of the application and high sensitivity.