• Title/Summary/Keyword: 미소위치결정

Search Result 39, Processing Time 0.025 seconds

A Study on the Ultraprecision Positioning Characteristic of Aerostatic Stage (공기정압 stage의 초정밀위치결정을 위한 기본특성)

  • 황주호;김중천;이재형;박천홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.175-178
    • /
    • 2000
  • An aerostatic stage has frictionless behavior, so it has a advantage of investigation into positioning characteristics. A one-dimensional aemstatic ceramic stage with ballscrew driven and laser scale feedback system is manufactured. aiming at investigating positioning characteristic of aerostatic stage, especially position error and repeatability, we analyze positioning behavior with other factors such as angular error, temperature. Experimemal results show that the aerostatic stage has a l0nm micro step response. Comparing experimental results and calculated abbe's error, we confirm that mean of position error is owing to angular error. And, also we confirm the temperature is dominant factor of repeatability in ten nm order.

  • PDF

Fast Simulation of Output Voltage for High-Shock Piezoresistive Microaccelerometer Using Mode Superposition Method and Least Square Method (모드중첩법 및 최소자승법을 통한 고충격 압저항 미소가속도계의 출력전압 해석)

  • Han, Jeong-Sam;Kwon, Ki-Beom
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.777-787
    • /
    • 2012
  • The transient analysis for the output voltage of a piezoresistive microaccelerometer takes a relatively high computation time because at least two iterations are required to calculate the piezoresistive-structural coupled response at each time step. In this study, the high computational cost for calculating the transient output voltage is considerably reduced by an approach integrating the mode superposition method and the least square method. In the approach, data on static displacement and output voltage calculated by piezoresistive-structural coupled simulation for three acceleration inputs are used to develop a quadratic regression model, relating the output voltage to the displacement at a certain observation point. The transient output voltage is then approximated by a regression model using the displacement response cheaply calculated by the mode superposition method. A high-impact microaccelerometer subject to several types of acceleration inputs such as 100,000 G shock, sine, step, and square pulses are adopted as a numerical example to represent the efficiency and accuracy of the suggested approach.

A Study on the Positioning Characteristic of Aerostatic Stage (공기베어링 스테이지의 이송특성 연구)

  • 황주호;박천홍;송창규;김중천
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.668-671
    • /
    • 2000
  • An aerostatic stage has frictionless behavior, so it has a advantage of investigation into driven mechanism such as ballscrew. In this paper, fur investigating positioning characteristic of ballscrew and feedback device in aerostatic stage, we compare the positioning characteristic between full-closed(laser scale) and semi-closed(encoder) system. Experimental results show that the aerostatic stage has a 10nm micro step response and repeatability is improved up to 1.00${\mu}{\textrm}{m}$ using laser scale. We confirm the laser scale compensate error motion of ballscrew, so acquire 1.12${\mu}{\textrm}{m}$ positioning accuracy.

  • PDF

Development of Micropositioning System Using a Magnetostrictive Material (자기변형재료를 이용한 마이크로포지쇼닝 시스템의 개발)

  • 박영우;원문철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.117-120
    • /
    • 1995
  • In this machining process, variation in cutting forces results in relative displacements between the tool and the workpiece leading to tool vibration. Also there is a demand to change the depth of cut very frequently. A soluion for both cases is to develop a system which has the ability to reposition a cutting tool to a very small level, i.e., micron. This ppaper presents the development of a micropositioning system (MPS) using a magnetostrictive material. The deveoped MPS is implemented to a lathe and subjected to static and machining test. The results show that the MPS has good potential for machining application

  • PDF

자기변형재료를 이용한 절삭공구용 마이크로포지쇼너의 개발

  • 박영우;원문철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.75-81
    • /
    • 1998
  • In the machining process, variation in cutting forces results in relative displacements between the tool and the workpiece leading to tool vibration. Also there is a demand to change the depth of cut very frequently. One solution for the both cases is to develop a system which has the ability to reposition a cutting tool to a very small level, i.e., micron. This paper presents the development of a micropositioner using a magnetostrictive material. The developed micropositioner is implemented to a lathe and subjected to various tests. The results show that the micropositioner with a magnetostrictive actuator has good potential for machining application.

  • PDF

새로운 형태의 3자유도 마이크로 매니플레이터

  • 정구봉;이병주;서일홍;김희국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.411-411
    • /
    • 2000
  • 본 논문에서는 새로운 형태의 정밀위치제어용 3자유도 매니플레이터를 제안하고, 기구학 해석을 수행하며, FEM과 수치해석적인 방법을 비교하여 메카니즘에 대한 모델링 방법이 크게 틀리지 않음을 확인 하고자 한다. 회전관절과 구형관절은 비구동관절로써 미소움직임이 가능하도록 하나의 모듈로 이루어진 flexure hinge들로 만들어진다. 따라서, 비구동관절에 대한 강성해석을 수행하며 구동관절의 토오크 벡터를 비구동관절의 강성과 변위로 표현하여 액추에이터의 구동용량을 결정한다.

  • PDF

Algorithm Development and Experimental Verification of Acoustic Emission First-arrival-time Determination for the Source Location (정확한 미소파괴음의 발생위치 분석을 위한 신호 도달시간 결정 알고리즘 연구 및 실험적 검증)

  • Jang, Hyun-Sic;Choi, Jun-Young;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.587-598
    • /
    • 2015
  • We examined various existing threshold methods for the determination of the first arrival time of acoustic emission (AE), and developed a new variable threshold method that could determine the first arrival time of AE more accurately and more quickly than existing methods. The new method, a modification of an existing threshold method, does not fix the threshold, but applies variable thresholds for the AE signals according to noise analysis. Two- and three-dimensional models were established to test the effectiveness of the new method. It could determine source locations of AE in a two-dimensional model 38.3% more accurately than the pre-existing threshold methods. Its accuracy improvement over the existing methods in a three-dimensional model was about 15.2%. A practical test involved measuring the source locations of AE during three-point bending tests of granite cores. The new method placed the sources closer to the fracture plane than did the pre-existing methods, indicating its superior (and quicker) ability to determine the source locations of AE.

Marangoni Convection Effects on Crystal Growth (결정 성장에서 Marangoni 대류의 영향)

  • 강승민;최종건;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.2 no.2
    • /
    • pp.77-82
    • /
    • 1992
  • When a crystal is grown by FZ process, the melt zone is located at between the solid of upper and lower side and is kept by the solid-liquid interface tension. On the surface of the melt zone, a surface tension gradient is occured by the difference of temperature and solute concentration, it is the driving force of marangoni flow. The crystal even in the steady state growth can become imperfect for the dislocation distribution and the solute concentration in the peripheral region of the crystal are higher than those in the inner part and the probability of the formation of the defects such as voids, bubble penetration, secondary phase creation and crack is high near the solid-liquid interface. This is because the solid -liquid interface becomes irregular because of the local variation of temperature in that region due to marangoni convection.

  • PDF

A Study on the Improvement of Microseismic Monitoring Accuracy by Borehole 3-Component Measurement Field Experiments (시추공 3성분 계측 현장실험을 통한 미소지진 모니터링 정확도 향상 연구)

  • Kim, Jungyul;Kim, Yoosung;Yun, Jeumdong;Kwon, Sungil;Kwon, Hyongil;Park, Seongbin;Park, Juhyun
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • In order to improve the accuracy of microseismic epicenter location through the inversion techniques using P and S wave first arrivals, field experiments of microseismic monitoring were performed using borehole 3-component geophones. The direction of epicenter was estimated from the hodograms of P-wave first arrivals through the weight drop experiments in which the $\times$ component of 3-component geophone was aligned to the magnetic north. The picking of S wave first arrival was possible in the polarization filtered data even if S waves are difficult to be identified in raw data. The inversion technique using only P wave first arrival times can often converge to the local minimum when the initial values for epicenter are largely apart from the true epicenter, so that the correct solution can not be found. To solve this problem, the epicenter determination method using differences between P and S wave arrival times was used to estimate proper initial values of epicenter. The inversion result using only P-wave first arrival times which started from the estimated initial values showed the improved accuracy of the epicenter location.

Exterior Orientation Parameters Determination from Satellite Imagery RPC Camera Model (위성영상 RPC 카메라 모델로부터 외부표정요소 결정)

  • Lee Hyo Sung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.1
    • /
    • pp.59-67
    • /
    • 2005
  • This paper proposes method for determining exterior orientation parameters (EOPs) from the RPC mathematical camera model of the satellite image. SPOT satellite stereo pair is pre-tested using the proposed method. As results that, geopositioning errors are similar with those of the original EOPs. Differences between EOPs determined from the RPC and original EOPs were small. IKONOS Geo-level stereo pair is tested by the proposed method. Results of this method are compared with those of the RPC block adjustment method which have been verified in reported studies. Consequently, the proposed method showed accuracy similar to the RPC block adjustment method. The digital elevation models (DEMs) of sample area acquired by the two method almost did not have a difference.