• Title/Summary/Keyword: 미세 제어

Search Result 855, Processing Time 0.033 seconds

Development of Xenon feed system for a 300 W Hall-effect Thruster (300 W급 홀 추력기를 위한 제논연료공급장치 개발)

  • Kim, Youn-Ho;Seon, Jong-Ho;Kang, Seong-Min;Wee, Jung-Hyun;Yoon, Ho-Sung;Choe, Won-Ho;Lee, Jong-Sub;Seo, Mi-Hui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.419-424
    • /
    • 2009
  • A Xenon feed system has been developed for a 300 W Hall-effect thruster intended for orbit maintenance of small satellite. The system can store about 2 kg of xenon gas at 150 bar and is capable of controlling the mass flow rate of the gas at 0.5 SCCM resolution. The performance of the system is verified with a laboratory experiment. It is confirmed that the operation of the feed system is successful at a pressure level of $1.0{\times}10^{-6}$ torr in the vacuum chamber.

마그네트론 스퍼터로 코팅된 알루미늄 박막의 미세구조 분석

  • Yang, Ji-Hun;Park, Hye-Seon;Jeong, Jae-Hun;Song, Min-A;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.159-159
    • /
    • 2012
  • 알루미늄 박막을 코팅하기 위해서 비대칭 마그네트론 스퍼터 소스를 이용하였으며 빗각 증착과 외부 자기장에 의한 플라즈마 밀도 제어가 알루미늄 박막의 미세구조에 미치는 영향을 확인하였다. 빗각 증착은 타겟과 기판이 서로 평행하지 않고 빗각을 이루도록 기판을 기울여 코팅하는 방법으로 박막의 미세구조를 제어할 수 있다. 마그네트론 스퍼터 소스 외부에 원형의 전자석을 위치시키고 직류의 전류를 인가하여 타겟 표면에서 발생하는 플라즈마 밀도를 제어할 수 있도록 하였다. 알루미늄을 물리기상증착으로 코팅하면 일반적으로 주상정 구조를 갖는다. 알루미늄 박막이 주상정 구조로 이루어지면 박막의 표면 거칠기가 증가하고 밀도가 감소하는 현상을 보인다. 알루미늄을 빗각 증착으로 코팅하면 주상정 형성이 억제되어 박막의 밀도가 높아지고 표면 거칠기는 감소하는 현상을 보였다. 알루미늄의 빗각 증착 시 전자석에 인가하는 전류의 세기와 방향을 제어하여 타겟 표면의 플라즈마 밀도를 증가시키면 알루미늄 박막의 밀도가 빗각 증착만 적용했을 때보다 증가하고 비정질과 같은 박막 구조를 보이는 현상을 관찰할 수 있었다. 전자석에 인가하는 전류의 방향을 기판 표면의 플라즈마 밀도가 증가하도록 바꾸면 알루미늄 주상정의 크기가 증가하고 기공의 크기도 증가하는 현상을 관찰하였다. 마그네트론 스퍼터 공정 시 자기장과 빗각 증착을 적절하게 이용하여 밀도가 높고 표면 거칠기가 낮은 알루미늄 박막을 코팅할 수 있었으며, 이러한 알루미늄 박막은 기능성 향상을 위한 표면처리 소재로 활용 가능성이 높을 것으로 판단된다.

  • PDF

탄소강의 신선 가공성에 미치는 미세조직의 영향

  • 배철민
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.05a
    • /
    • pp.60-65
    • /
    • 1999
  • 신선 가공용 소재로 사용되는 $0.4\%C$이상의 탄소강의 신선성은 미세조직 변화에 크게 영향을 받다 제2상으로 존재하는 초석 페라이트 또는 세멘타이트의 형성을 적극 억제하여야 한다. 펄라이트 조직에서는 오스테나이트 결정립 크기 및 세멘타이트 두께를 미세하게 하는 것이 신선성 향상에 유리하며 특히 아공석강에서 펄라이트 단상으로 미세조직을 제어하면 매우 우수한 신선성의 향상을 얻을 수 있어 신선 도중 실시하는 중간 열처리를 생략할 수 있다.

  • PDF

Position Control of Micro Particles in a Fluid Flow Using Ultrasonic Standing Wave (정재초음파를 이용한 유동중 미세 입자 위치 제어)

  • Cho, Seung-Hyun;Seo, Dae-Cheol;Ahn, Bong-Young;Kim, Ki-Bok;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • Using ultrasonic standing waves, micro particles submerged or flowing in fluid can be manipulated. Due to acoustic radiation force of ultrasound, particles are forced to move to pressure nodal or antinodal lines. In this work, we propose a method to control the position of micro particle in a flow by adjusting the frequency of the standing wave. To this end, standing wave field generation system including a few millimeter thick micro channel was established using an immersible ultrasonic transducer. The present generation system works valid in a frequency range between 2.0 MHz and 2.5 MHz. We observed the SiC particles in water moved to pressure nodal lines by the standing wave. The effect of the channel thickness and operating frequency was also investigated. Interestingly, it was shown that the operating frequency have a close relation with the location of the pressure nodal line. Consequently, it fan be said that the position of particle movement rail be controlled by adjusting the ultrasound frequency. The maximum range of the controllable position was about 261 micrometers under the given condition. The resulted observations reveal the possibility of various applications of the ultrasonic standing wave to the manipulation of particles submerged in a fluid.

Controlled Production of Monodisperse Polycaprolactone Microparticles using Microfluidic Device (미세유체장치를 이용한 생분해성 Polycarprolactone의 단분산성 미세입자 생성제어)

  • Jeong, Heon-Ho
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.283-288
    • /
    • 2019
  • Monodisperse microparticles has been particularly enabling for various applications in the encapsulation and delivery of pharmaceutical agents. The microfluidic devices are attractive candidates to produce highly uniform droplets that serve as templates to form monodisperse microparticles. The microfluidic devices that have micro-scale channel allow precise control of the balance between surface tension and viscous forces in two-phase flows. One of its essential abilities is to generate highly monodisperse droplets. In this paper, a microfluidic approach for preparing monodisperse polycaprolactone (PCL) microparticles is presented. The microfluidic devices that have a flow-focusing generator are manufactured by soft-lithography using polydimethylsiloxane (PDMS). The crucial factors in the droplet generation are the controllability of size and monodispersity of the microdroplets. For this, the volumetric flow rates of the dispersed phase of oil solution and the continuous phase of water to generate monodisperse droplets are optimized. As a result, the optimal flow condition for droplet dripping region that is able to generate uniform droplet is found. Furthermore, the droplets containing PCL polymer by solvent evaporation after collection of droplet from device is solidified to generate the microparticle. The particle size can be controlled by tuning the flow rate and the size of the microchannel. The monodispersity of the PCL particles is measured by a coefficient of variation (CV) below 5%.

Fine Gap Control Using Pneumatic Servo System (공압서보시스템에 의한 미세 간극제어 시스템 설계)

  • 김동환;김영진;정대화
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.45-56
    • /
    • 2002
  • A pneumatic servo system requiring a fine gap control in a photo-electric sensor which is used for a LCD array detection device is introduced. The gap controlled by the pneumatic servo system remains within around 50~80 ${\mu}{\textrm}{m}$, and the system possesses an effect to eliminate undesirable particles on the LCD plate by blowing air out. The air flow rate is initially controlled by a servo valve and expanded by a booster valve, thus the controlled air pressure contributes to maintaining an appropriate gap between the LCD plate and photo-electric sensor An air floating plate of two degrees of freedom is designed and fabricated, and a fine tilting motion control is also implemented by assigning different gap commands. The pressure control and direct gap control are proposed, and each performance is verified experimentally.

Integrated microfluidic device with polymer-based micropump and microvalve for $\mu$-TAS devices (마이크로 펌프, 밸브가 집적된 폴리머 기반의 미세 유체제어 시스템의 기계적 특성 강화)

  • Ra, Gyu-Sik;Jha, Sandeep Kumar;Yoon, Tae-Sik;Lee, Hyun-Ho;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1458-1459
    • /
    • 2008
  • 미세 유체 제어 시스템 (마이크로 펌프, 마이크로 밸브, 마이크로 채널, 마이크로 믹서 등)의 집적은 화학 및 바이오 유체를 제어하는 Lab-on-a-chip 의 일부분으로서 사용되며 이러한 시스템의 집적은 Lab-on-a-chip 개발을 위해 필수적으로 요구된다. 본 논문에서는 이러한 microchip을 구현하기 위해서 초미세 유체 제어 소자인 마이크로 펌프와 마이크로 밸브를 같은 기판 위에 Polydimethylsiloxane (PDMS)와 indium tin oxade (ITO)를 사용하여 집적하였다. 그리고 밸브의 반복 작동 시 계속적인 유량의 감소를 줄이기 위해 PDMS 의 혼합비를 달리하여 PDMS membrane 의 기계적 특성을 강화시켰다.

  • PDF

An Efficient Fine-Grained Access Control System for XML Documents (XML문서를 위한 효율적인 미세 접근 제어 시스템)

  • 이승현;이헌길;강정모
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10a
    • /
    • pp.826-828
    • /
    • 2003
  • 본 논문에서는 XML 문서의 보다 효율적인 접근 제어를 위하여 XML 문서 전체 단위의 접근이 아닌 문서 내 노드 등과 같이 세밀한 부분에 접근 제어를 할 수 있는 미세 접근 제어 기법을 사용하였다. 현재 제안되어 사용되고 있는 묵시적 권한 기법은 상위 구성요소에 한번의 권한 부여로 하위 노드에 권한을 부여하는 효과를 가지는 장점을 가지고 있지만 각각의 구성요소간의 권한을 체크하는 시간의 오버헤드를 가지는 단점이 있다. 이러한 권한을 체크하는 시간을 감소시키기 위하여 본 논문에서는 저장 공간의 오버헤드가 있지만, 권한체크의 시간을 감소시켜서 사용자에게 보다 빠른 view를 제공할 수 있는 XML 문서를 위한 명시적 트리 모델과 view 생성 알고리즘을 제안하였다.

  • PDF

Telerobotic Microsurigical Robot Design based on the analysis of Microsurgery (미세수술 동작분석을 통한 원격제어 수술로봇 설계)

  • 송세경;권동수
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.401-407
    • /
    • 1999
  • A microsurgery telerobotic system has been developed to aid surgeons from physiological tremor, eye stram, hand tremor, contagious and radioactive hazard. This paper identifies four general areas of advanced microsurgery and analyzes the motion, tools, accuracy and applying forces with respect to microsurgery tasks, and proposes the criteria to design the microsurgical robot. The analysis of microsurgery can be helpful to clarify some basic concept and design of surgical robots. Based on this analysis results, we propose an efficient in-parallel-platform manipulator having a special kinematic structure suitable for microsurgery.

  • PDF